Thermal-light full-field optical coherence tomography in the 1.2 μm wavelength region

被引:49
作者
Dubois, Arnaud [1 ]
Moneron, Gael [1 ]
Boccara, Claude [1 ]
机构
[1] Ecole Super Phys & Chim Ind Ville Paris, CNRS, UPR A0005, Lab Opt Phys, F-75231 Paris 5, France
关键词
optical coherence tomography; biomedical imaging; optical tomography; microscopy; infrared camera;
D O I
10.1016/j.optcom.2006.05.016
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Full-field optical coherence tomography with dynamic focusing correction is demonstrated in the 1.2 mu m wavelength region using an Indium Gallium Arsenide area camera as image sensor and a halogen lamp as illumination source. An axial image resolution of 1.6 mu m is measured in air (similar to 1.1 mu m in tissue) which is the best resolution ever achieved in OCT in this wavelength region. En face tomographic images are produced using a phase-shifting method requiring the acquisition of only two phase-opposed interferometric images. In spite of a relatively moderate detection sensitivity of 80 dB within 1.0s image acquisition time, ultrahigh resolution imaging in highly scattering biological tissues is possible without immersion medium. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:738 / 743
页数:6
相关论文
共 29 条
[1]   THE OPTICS OF HUMAN-SKIN [J].
ANDERSON, RR ;
PARRISH, JA .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1981, 77 (01) :13-19
[2]   Full-field optical coherence microscopy [J].
Beaurepaire, E ;
Boccara, AC ;
Lebec, M ;
Blanchot, L ;
Saint-Jalmes, H .
OPTICS LETTERS, 1998, 23 (04) :244-246
[4]   Compact, broad-bandwidth fiber laser for sub-2-μm axial resolution optical coherence tomography in the 1300-nm wavelength region [J].
Bizheva, K ;
Povazay, B ;
Hermann, B ;
Sattmann, H ;
Drexler, W ;
Mei, M ;
Holzwarth, R ;
Hoelzenbein, T ;
Wacheck, V ;
Pehamberger, H .
OPTICS LETTERS, 2003, 28 (09) :707-709
[5]   Wide-field optical coherence tomography:: imaging of biological tissues [J].
Bordenave, E ;
Abraham, E ;
Jonusauskas, G ;
Tsurumachi, N ;
Oberlé, J ;
Rullière, C ;
Minot, PE ;
Lassègues, M ;
Bazeille, JES .
APPLIED OPTICS, 2002, 41 (10) :2059-2064
[6]   All-solid-state Cr:forsterite laser generating 14-fs pulses at 1.3 μm [J].
Chudoba, C ;
Fujimoto, JG ;
Ippen, EP ;
Haus, HA ;
Morgner, U ;
Kärtner, FX ;
Scheuer, V ;
Angelow, G ;
Tschudi, T .
OPTICS LETTERS, 2001, 26 (05) :292-294
[7]  
Davidson M., 1987, Proceedings of the SPIE - The International Society for Optical Engineering, V775, P233, DOI 10.1117/12.940433
[8]   Three-dimensional cellular-level imaging using full-field optical coherence tomography [J].
Dubois, A ;
Moneron, G ;
Grieve, K ;
Boccara, AC .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (07) :1227-1234
[9]   Ultrahigh-resolution full-field optical coherence tomography [J].
Dubois, A ;
Grieve, K ;
Moneron, G ;
Lecaque, R ;
Vabre, L ;
Boccara, C .
APPLIED OPTICS, 2004, 43 (14) :2874-2883
[10]   High-resolution full-field optical coherence tomography with a Linnik microscope [J].
Dubois, A ;
Vabre, L ;
Boccara, AC ;
Beaurepaire, E .
APPLIED OPTICS, 2002, 41 (04) :805-812