The role of technology in clinical trials using stereotactic body radiotherapy

被引:2
作者
Aznar, Marianne [1 ,2 ]
Romero, Alejandra Mendez [3 ]
Heijmen, Ben J. M. [3 ]
机构
[1] Univ Oxford, Nuffield Dept Populat Hlth, Clin Trial Serv Unit, Oxford, England
[2] Univ Copenhagen, Dept Oncol, Rigshosp, Copenhagen, Denmark
[3] Erasmus MC Canc Inst, Dept Radiat Oncol, Rotterdam, Netherlands
基金
英国医学研究理事会;
关键词
RADIATION-THERAPY; DIGITAL TOMOSYNTHESIS; DOSE DELIVERY; LUNG-TUMORS; EXPERIENCE; SBRT;
D O I
10.1259/bjr.20160930
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Stereotactic body radiotherapy is a highly technology-driven treatment modality. The wider availability of in-room imaging and advanced radiotherapy delivery techniques has led to more institutions offering stereotactic ablative therapy (SABR). While some technological challenges remain, the crucial point for the next generation of SABR clinical trials is that today's technology is used correctly and close to its optimal potential for accuracy. The credentialing procedure of SABR needs to be extensive, but this investment will benefit the trial itself, the patients and the professionals involved.
引用
收藏
页数:3
相关论文
共 16 条
[1]   STEREOTAXIC HIGH-DOSE FRACTION RADIATION-THERAPY OF EXTRACRANIAL TUMORS USING AN ACCELERATOR - CLINICAL-EXPERIENCE OF THE FIRST 31 PATIENTS [J].
BLOMGREN, H ;
LAX, I ;
NASLUND, I ;
SVANSTROM, R .
ACTA ONCOLOGICA, 1995, 34 (06) :861-870
[2]   Multileaf Collimator Tracking Improves Dose Delivery for Prostate Cancer Radiation Therapy: Results of the First Clinical Trial [J].
Colvill, Emma ;
Booth, Jeremy T. ;
O'Brien, Ricky T. ;
Eade, Thomas N. ;
Kneebone, Andrew B. ;
Poulsen, Per R. ;
Keall, Paul J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 92 (05) :1141-1147
[3]   Treating patients with real-time tumor tracking using the Vero gimbaled linac system: Implementation and first review [J].
Depuydt, Tom ;
Poels, Kenneth ;
Verellen, Dirk ;
Engels, Benedikt ;
Collen, Christine ;
Buleteanu, Manuela ;
Van den Begin, Robbe ;
Boussaer, Marlies ;
Duchateau, Michael ;
Gevaert, Thierry ;
Storme, Guy ;
De Ridder, Mark .
RADIOTHERAPY AND ONCOLOGY, 2014, 112 (03) :343-351
[4]   CyberKnife Stereotactic Ablative Radiotherapy for Lung Tumors [J].
Gibbs, Iris C. ;
Loo, Billy W., Jr. .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (06) :589-596
[5]   Dose-response relationship with clinical outcome for lung stereotactic body radiotherapy (SBRT) delivered via online image guidance [J].
Kestin, Larry ;
Grills, Inga ;
Guckenberger, Matthias ;
Belderbos, Jose ;
Hope, Andrew J. ;
Werner-Wasik, Maria ;
Sonke, Jan-Jakob ;
Bissonnette, Jean-Pierre ;
Xiao, Ying ;
Yan, Di .
RADIOTHERAPY AND ONCOLOGY, 2014, 110 (03) :499-504
[6]  
KIHLSTROM L, 1993, STEREOT FUNCT NEUROS, V61, P45, DOI 10.1159/000100659
[7]   Lungtech, a phase II EORTC trial of SBRT for centrally located lung tumours - a clinical physics perspective [J].
Lambrecht, Marie ;
Melidis, Christos ;
Sonke, Jan-Jakob ;
Adebahr, Sonja ;
Boellaard, Ronald ;
Verheij, Marcel ;
Guckenberger, Matthias ;
Nestle, Ursula ;
Hurkmans, Coen .
RADIATION ONCOLOGY, 2016, 11
[8]   STEREOTAXIC RADIOTHERAPY OF MALIGNANCIES IN THE ABDOMEN - METHODOLOGICAL ASPECTS [J].
LAX, I ;
BLOMGREN, H ;
NASLUND, I ;
SVANSTROM, R .
ACTA ONCOLOGICA, 1994, 33 (06) :677-683
[9]   Adaptive Liver Stereotactic Body Radiation Therapy: Automated Daily Plan Reoptimization Prevents Dose Delivery Degradation Caused by Anatomy Deformations [J].
Leinders, Suzanne M. ;
Breedveld, Sebastiaan ;
Romero, Alejandra Mendez ;
Schaart, Dennis ;
Seppenwoolde, Yvette ;
Heijmen, Ben J. M. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (05) :1016-1021
[10]   OBSERVATION OF A DOSE-CONTROL RELATIONSHIP FOR LUNG AND LIVER TUMORS AFTER STEREOTACTIC BODY RADIATION THERAPY [J].
McCammon, Robert ;
Schefter, Tracey E. ;
Gaspar, Laurie E. ;
Zaemisch, Rebekah ;
Gravdahl, Daniel ;
Kavanagh, Brian .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (01) :112-118