Anisotropic ion diffusivity in intervertebral disc: An electrical conductivity approach

被引:31
作者
Jackson, Alicia
Yao, Hai
Brown, Mark D.
Gu, Wei Yong
机构
[1] Univ Miami, Coll Engn, Dept Biomed Engn, Tissue Biomech Lab, Coral Gables, FL 33124 USA
[2] Clemson Univ, Dept Bioengn, Clemson, SC 29631 USA
[3] Univ Miami, Dept Orthopaed & Rehabil, Miami, FL 33152 USA
关键词
annulus fibrosis; nucleus pulposus; electrical conductivity; ion diffusion coefficient; anisotropic; spine;
D O I
10.1097/01.brs.0000245842.02717.1b
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Investigation of the transport behavior of ions in intervertebral disc using an electrical conductivity method. Objectives. To determine the electrical conductivity and ion diffusivity of nucleus pulposus and anulus fibrosus in 3 major directions ( axial, circumferential, and radial). Summary of Background Data. Knowledge of diffusivity of small molecules is important for understanding nutrition supply in intervertebral disc and disc degeneration. However, little is known on the anisotropic behaviors of ion diffusivity and of electrical conductivity in intervertebral disc. Methods. Electrical conductivity measurement was performed on 24 axial, circumferential, and radial anulus fibrosus specimens and 24 axial nucleus pulposus specimens from bovine coccygeal discs. The diffusivity of Na+ and Cl- were estimated by the analysis of conductivity data. Results. The electrical conductivity (mean +/- standard deviation; n = 24) of the bovine anulus fibrosus was 4.70 +/- 1.08 mS/cm in the axial, 2.86 +/- 0.83 mS/cm in the radial, and 4.38 +/- 1.25 mS/cm in the circumferential direction. For nucleus pulposus, the electrical conductivity (mean +/- standard deviation; n = 24) was 8.95 +/- 0.89 mS/cm. The mean value for nucleus pulposus was significantly higher than that of anulus fibrosus (t test, P < 0.05). For anulus fibrosus, the conductivity in the radial direction was significantly lower than in axial or circumferential directions. Similar trends were found for both Na+ and Cl- diffusivities. Both electrical conductivity and ion diffusivity were highly sensitive to water content. Conclusions. Electrical conductivity and ion diffusivity of anulus fibrosus are anisotropic.
引用
收藏
页码:2783 / 2789
页数:7
相关论文
共 49 条
  • [1] The effect of dynamic compression on the response of articular cartilage to insulin-like growth factor-I
    Bonassar, LJ
    Grodzinsky, AJ
    Frank, EH
    Davila, SG
    Bhaktav, NR
    Trippel, SB
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2001, 19 (01) : 11 - 17
  • [2] BROWN M D, 1976, Spine, V1, P240, DOI 10.1097/00007632-197612000-00009
  • [3] SPINE UPDATE - AGING AND DEGENERATION OF THE HUMAN INTERVERTEBRAL DISC
    BUCKWALTER, JA
    [J]. SPINE, 1995, 20 (11) : 1307 - 1314
  • [4] DIFFUSION OF SMALL SOLUTES IN CARTILAGE AS MEASURED BY NUCLEAR-MAGNETIC-RESONANCE (NMR) SPECTROSCOPY AND IMAGING
    BURSTEIN, D
    GRAY, ML
    HARTMAN, AL
    GIPE, R
    FOY, BD
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1993, 11 (04) : 465 - 478
  • [5] A MICROCONTINUUM MODEL OF ELECTROKINETIC COUPLING IN THE EXTRACELLULAR-MATRIX - PERTURBATION FORMULATION AND SOLUTION
    CHAMMAS, P
    FEDERSPIEL, WJ
    EISENBERG, SR
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1994, 168 (02) : 526 - 538
  • [6] Chiu E J, 2001, Spine (Phila Pa 1976), V26, pE437, DOI 10.1097/00007632-200110010-00017
  • [7] ANATOMIC STUDIES OF THE CIRCULATION IN THE REGION OF THE VERTEBRAL ENDPLATE IN ADULT GREYHOUND DOGS
    CROCK, HV
    GOLDWASSER, M
    [J]. SPINE, 1984, 9 (07) : 702 - 706
  • [8] EISENBERG SR, 1988, PHYSICOCHEM HYDRODYN, V10, P517
  • [9] EYRE D, 1989, NEW PERSPECTIVES ON LOW BACK PAIN, P147
  • [10] Frank E.H., 1990, Biomechanics of Diarthrodial Joints, P261, DOI DOI 10.1007/978-1-4612-3448-7_9