The 2D-3D Registration Method in Image Fusion Is Accurate and Helps to Reduce the Used Contrast Medium, Radiation, and Procedural Time in Standard EVAR Procedures

被引:18
作者
Ahmad, Wael [1 ]
Obeidi, Youssra [2 ]
Majd, Payman [1 ]
Brunkwall, Jan Sigge [1 ]
机构
[1] Univ Hosp Cologne, Dept Vasc & Endovasc Surg, Cologne, Germany
[2] Univ Cologne, Fac Med, Cologne, Germany
关键词
AORTIC-ANEURYSM REPAIR; UNITED-STATES; EXPOSURE; FEASIBILITY; GUIDANCE; EPIDEMIOLOGY; ANGIOGRAPHY; SYSTEM; IMPACT;
D O I
10.1016/j.avsg.2018.01.098
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study aimed to evaluate the accuracy and the effectiveness of 2D-3D registration method of image fusion (IF) technology in endovascular aneurysm repair (EVAR). Methods: We performed a review of our institutional endovascular aortic database of patients who had undergone EVAR between 2011 and 2015 before and after the installation of a 3D IF computed tomography system in our hybrid operating room. Results: The accuracy was assessed in 14 endovascular procedures and showed a median registration error of 1.8 mm at the origin of the right renal artery and 1.0 mm at the origin of the left renal artery and a complete visual accuracy in 42% of the cases. EVAR was performed using the intraoperative IF technique with a 2D-3D registration method in 105 patients (group IF), whereas 47 patients done without served as controls. The IF group had a significantly reduced amount of used contrast compared with controls with a median of 58 mL and P < 0.0001. The intraoperative exposition to radiation was similar between the 2 groups with a median dose area product of 2,343.7 cGy cm(2) in the IF group and 3,219 cGy cm 2 among the controls (P = 0.457). The radiation dose in the sub group IF (including patients operated by the 2 most experienced surgeons) was lower than that in sub controls (median, 1,087 cG cm(2) vs. 2,705.3 cG cm(2), P = 0.012). The procedure time and the time of intraoperative radiation did not differ between the study groups (P = 0.117 and 0.106, respectively), as did not fluoroscopy time in the sub group IF (median, 6.3 min, vs. 9.5 min, P = 0.067), but for the 2 most experienced surgeons, the procedural time was shortened when using IF (P = 0.002). Conclusions: The 2D-3D registration method of IF guidance is accurate to delineate the vessels of interest and could help the execution of the EVAR procedures with a significantly reduced amount of contrast medium and also with reduced radiation and shorter procedural duration when surgeons are more familiar with EVAR and IF.
引用
收藏
页码:177 / 186
页数:10
相关论文
共 17 条
  • [1] Feasibility and Limitations of an Automated 2D-3D Rigid Image Registration System for Complex Endovascular Aortic Procedures
    Carrell, Tom W. G.
    Modarai, Bijan
    Brown, James R. I.
    Penney, Graeme P.
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2010, 17 (04) : 527 - 533
  • [2] Intraoperative C-arm cone-beam computed tomography in fenestrated/branched aortic endo grafting
    Dijkstra, Martijn L.
    Eagleton, Matthew J.
    Greenberg, Roy K.
    Mastracci, Tara
    Hernandez, Adrian
    [J]. JOURNAL OF VASCULAR SURGERY, 2011, 53 (03) : 583 - 590
  • [3] Epidemiology of aortic aneurysm repair in the United States from 2000 to 2010
    Dua, Anahita
    Kuy, SreyRam
    Lee, Cheong J.
    Upchurch, Gilbert R., Jr.
    Desai, Sapan S.
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 59 (06) : 1512 - 1517
  • [4] Evaluation of Automated 2D-3D Image Overlay System Utilizing Subtraction of Bone Marrow Image for EVAR: Feasibility Study
    Fukuda, T.
    Matsuda, H.
    Doi, S.
    Sugiyama, M.
    Morita, Y.
    Yamada, M.
    Yokoyama, H.
    Minatoya, K.
    Kobayashi, J.
    Naito, H.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2013, 46 (01) : 75 - 81
  • [5] Repeated contrast medium application after endovascular aneurysm repair and not the type of endograft fixation seems to have deleterious effect on the renal function
    Gray, Daphne Elisabeth
    Eisenack, Markus
    Gawenda, Michael
    Torsello, Giovanni
    Majd, Payman
    Brunkwall, Jan
    Osada, Nani
    Donas, Konstantinos P.
    [J]. JOURNAL OF VASCULAR SURGERY, 2017, 65 (01) : 46 - 51
  • [6] Impact of Hybrid Rooms with Image Fusion on Radiation Exposure during Endovascular Aortic Repair
    Hertault, A.
    Maurel, B.
    Sobocinski, J.
    Gonzalez, T. Martin
    Le Roux, M.
    Azzaoui, R.
    Midulla, M.
    Haulon, S.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 48 (04) : 382 - 390
  • [7] Impact of cumulative intravascular contrast exposure on renal function in patients with occlusive and aneurysmal vascular disease
    Kougias, Panos
    Sharath, Sherene
    Barshes, Neal R.
    Lowery, Briauna
    Garcia, Andrea
    Pak, Taemee
    Bechara, Carlos F.
    Pisimisis, George
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 59 (06) : 1644 - 1650
  • [8] The epidemiology of surgically repaired aneurysms in the United States
    Lawrence, PF
    Gazak, C
    Bhirangi, L
    Jones, B
    Bhirangi, K
    Oderich, G
    Treiman, G
    [J]. JOURNAL OF VASCULAR SURGERY, 1999, 30 (04) : 632 - 640
  • [9] Three-dimensional fusion computed tomography decreases radiation exposure, procedure time, and contrast use during fenestrated endovascular aortic repair
    McNally, Michael M.
    Scali, Salvatore T.
    Feezor, Robert J.
    Neal, Daniel
    Huber, Thomas S.
    Beck, Adam W.
    [J]. JOURNAL OF VASCULAR SURGERY, 2015, 61 (02) : 309 - 316
  • [10] CTA with Fluoroscopy Image Fusion Guidance in Endovascular Complex Aortic Aneurysm Repair
    Sailer, A. M.
    de Haan, M. W.
    Peppelenbosch, A. G.
    Jacobs, M. J.
    Wildberger, J. E.
    Schurink, G. W. H.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 47 (04) : 349 - 356