The 2D-3D Registration Method in Image Fusion Is Accurate and Helps to Reduce the Used Contrast Medium, Radiation, and Procedural Time in Standard EVAR Procedures

被引:18
作者
Ahmad, Wael [1 ]
Obeidi, Youssra [2 ]
Majd, Payman [1 ]
Brunkwall, Jan Sigge [1 ]
机构
[1] Univ Hosp Cologne, Dept Vasc & Endovasc Surg, Cologne, Germany
[2] Univ Cologne, Fac Med, Cologne, Germany
关键词
AORTIC-ANEURYSM REPAIR; UNITED-STATES; EXPOSURE; FEASIBILITY; GUIDANCE; EPIDEMIOLOGY; ANGIOGRAPHY; SYSTEM; IMPACT;
D O I
10.1016/j.avsg.2018.01.098
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study aimed to evaluate the accuracy and the effectiveness of 2D-3D registration method of image fusion (IF) technology in endovascular aneurysm repair (EVAR). Methods: We performed a review of our institutional endovascular aortic database of patients who had undergone EVAR between 2011 and 2015 before and after the installation of a 3D IF computed tomography system in our hybrid operating room. Results: The accuracy was assessed in 14 endovascular procedures and showed a median registration error of 1.8 mm at the origin of the right renal artery and 1.0 mm at the origin of the left renal artery and a complete visual accuracy in 42% of the cases. EVAR was performed using the intraoperative IF technique with a 2D-3D registration method in 105 patients (group IF), whereas 47 patients done without served as controls. The IF group had a significantly reduced amount of used contrast compared with controls with a median of 58 mL and P < 0.0001. The intraoperative exposition to radiation was similar between the 2 groups with a median dose area product of 2,343.7 cGy cm(2) in the IF group and 3,219 cGy cm 2 among the controls (P = 0.457). The radiation dose in the sub group IF (including patients operated by the 2 most experienced surgeons) was lower than that in sub controls (median, 1,087 cG cm(2) vs. 2,705.3 cG cm(2), P = 0.012). The procedure time and the time of intraoperative radiation did not differ between the study groups (P = 0.117 and 0.106, respectively), as did not fluoroscopy time in the sub group IF (median, 6.3 min, vs. 9.5 min, P = 0.067), but for the 2 most experienced surgeons, the procedural time was shortened when using IF (P = 0.002). Conclusions: The 2D-3D registration method of IF guidance is accurate to delineate the vessels of interest and could help the execution of the EVAR procedures with a significantly reduced amount of contrast medium and also with reduced radiation and shorter procedural duration when surgeons are more familiar with EVAR and IF.
引用
收藏
页码:177 / 186
页数:10
相关论文
共 17 条
[1]   Feasibility and Limitations of an Automated 2D-3D Rigid Image Registration System for Complex Endovascular Aortic Procedures [J].
Carrell, Tom W. G. ;
Modarai, Bijan ;
Brown, James R. I. ;
Penney, Graeme P. .
JOURNAL OF ENDOVASCULAR THERAPY, 2010, 17 (04) :527-533
[2]   Intraoperative C-arm cone-beam computed tomography in fenestrated/branched aortic endo grafting [J].
Dijkstra, Martijn L. ;
Eagleton, Matthew J. ;
Greenberg, Roy K. ;
Mastracci, Tara ;
Hernandez, Adrian .
JOURNAL OF VASCULAR SURGERY, 2011, 53 (03) :583-590
[3]   Epidemiology of aortic aneurysm repair in the United States from 2000 to 2010 [J].
Dua, Anahita ;
Kuy, SreyRam ;
Lee, Cheong J. ;
Upchurch, Gilbert R., Jr. ;
Desai, Sapan S. .
JOURNAL OF VASCULAR SURGERY, 2014, 59 (06) :1512-1517
[4]   Evaluation of Automated 2D-3D Image Overlay System Utilizing Subtraction of Bone Marrow Image for EVAR: Feasibility Study [J].
Fukuda, T. ;
Matsuda, H. ;
Doi, S. ;
Sugiyama, M. ;
Morita, Y. ;
Yamada, M. ;
Yokoyama, H. ;
Minatoya, K. ;
Kobayashi, J. ;
Naito, H. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2013, 46 (01) :75-81
[5]   Repeated contrast medium application after endovascular aneurysm repair and not the type of endograft fixation seems to have deleterious effect on the renal function [J].
Gray, Daphne Elisabeth ;
Eisenack, Markus ;
Gawenda, Michael ;
Torsello, Giovanni ;
Majd, Payman ;
Brunkwall, Jan ;
Osada, Nani ;
Donas, Konstantinos P. .
JOURNAL OF VASCULAR SURGERY, 2017, 65 (01) :46-51
[6]   Impact of Hybrid Rooms with Image Fusion on Radiation Exposure during Endovascular Aortic Repair [J].
Hertault, A. ;
Maurel, B. ;
Sobocinski, J. ;
Gonzalez, T. Martin ;
Le Roux, M. ;
Azzaoui, R. ;
Midulla, M. ;
Haulon, S. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 48 (04) :382-390
[7]   Impact of cumulative intravascular contrast exposure on renal function in patients with occlusive and aneurysmal vascular disease [J].
Kougias, Panos ;
Sharath, Sherene ;
Barshes, Neal R. ;
Lowery, Briauna ;
Garcia, Andrea ;
Pak, Taemee ;
Bechara, Carlos F. ;
Pisimisis, George .
JOURNAL OF VASCULAR SURGERY, 2014, 59 (06) :1644-1650
[8]   The epidemiology of surgically repaired aneurysms in the United States [J].
Lawrence, PF ;
Gazak, C ;
Bhirangi, L ;
Jones, B ;
Bhirangi, K ;
Oderich, G ;
Treiman, G .
JOURNAL OF VASCULAR SURGERY, 1999, 30 (04) :632-640
[9]   Three-dimensional fusion computed tomography decreases radiation exposure, procedure time, and contrast use during fenestrated endovascular aortic repair [J].
McNally, Michael M. ;
Scali, Salvatore T. ;
Feezor, Robert J. ;
Neal, Daniel ;
Huber, Thomas S. ;
Beck, Adam W. .
JOURNAL OF VASCULAR SURGERY, 2015, 61 (02) :309-316
[10]   CTA with Fluoroscopy Image Fusion Guidance in Endovascular Complex Aortic Aneurysm Repair [J].
Sailer, A. M. ;
de Haan, M. W. ;
Peppelenbosch, A. G. ;
Jacobs, M. J. ;
Wildberger, J. E. ;
Schurink, G. W. H. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 47 (04) :349-356