Size and direction of hip joint forces associated with various positions of the acetabulum

被引:21
作者
Lengsfeld, M [1 ]
Bassaly, A [1 ]
Boudriot, U [1 ]
Pressel, T [1 ]
Griss, P [1 ]
机构
[1] Univ Marburg, Dept Orthopaed Surg, D-35033 Marburg, Germany
关键词
hip joint center; force; force direction; acetabular component;
D O I
10.1016/S0883-5403(00)90624-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
When total hip replacement is performed, the position.,tl of the acetabular component may affect wear and component survival time. We considered the questions: In what way does displacement of Ihc hip joins center alter (1) the magnitude and (2) the direction of the resultant force? Biomechanical tests were carried out on a human multibody model. After displacement of the hip joint center the resultant forces were calculated for the single leg stance. With the flexed single leg stance, maximum hip joint forces were observed with lateral, cranial, posterior displacement. The peak Forces were affected by the modeling of a gluteus maximus wrapping point ar the ischial tuberosity and were overestimated when this was removed. With the straight single leg stance. posterior displacement decreases the total load on the hip joint because of the increased leverage of the rectus femoris. With regard to the direction of the resultant force, medial displacement increases the angles in both planes, cranial displacement increases it in the sagittal plane (cranial, posterior-caudal, anterior), and anterior displacement decreases the angle in the sagittal plane and increases it in the frontal plane (medial, cranial-lateral. caudal). The direction of the force is relatively insensitive to displacement of the hip joint center. Thr results presented here indicate a marked increase in the force after lateral, cranial posterior displacement of the center in the flexed single let: stance. To avoid extreme joint loading and to reduce the wear after total hip arthoplasty, the cranial and posterior regions of the acetabulum should be fully reconstructed. A high hip joint center has an adverse effect on the magnitude of the force. although the directions are hardly affected by it.
引用
收藏
页码:314 / 320
页数:7
相关论文
共 25 条
[1]   HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[2]   IS STAIRCASE WALKING A RISK FOR THE FIXATION OF HIP IMPLANTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1995, 28 (05) :535-553
[3]  
Brand R A, 1994, J Arthroplasty, V9, P45, DOI 10.1016/0883-5403(94)90136-8
[4]   THE SENSITIVITY OF MUSCLE FORCE PREDICTIONS TO CHANGES IN PHYSIOLOGICAL CROSS-SECTIONAL AREA [J].
BRAND, RA ;
PEDERSEN, DR ;
FRIEDERICH, JA .
JOURNAL OF BIOMECHANICS, 1986, 19 (08) :589-596
[5]  
CHANDLER RF, 1975, INVESTIGATIONS INERT
[6]  
DANTONIO JA, 1989, CLIN ORTHOP RELAT R, P126
[7]   SUPERIOR DISPLACEMENT OF THE HIP IN TOTAL JOINT REPLACEMENT - EFFECTS OF PROSTHETIC NECK LENGTH, NECK-STEM ANGLE, AND ANTEVERSION ANGLE ON THE MOMENT-GENERATING CAPACITY OF THE MUSCLES [J].
DELP, SL ;
KOMATTU, AV ;
WIXSON, RL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (06) :860-870
[8]   EFFECTS OF HIP CENTER LOCATION ON THE MOMENT-GENERATING CAPACITY OF THE MUSCLES [J].
DELP, SL ;
MALONEY, W .
JOURNAL OF BIOMECHANICS, 1993, 26 (4-5) :485-499
[9]  
Delp SL, 1996, CLIN ORTHOP RELAT R, P137
[10]   Effect of superior and superolateral relocations of the hip center on hip joint forces - An experimental and analytical analysis [J].
Doehring, TC ;
Rubash, HE ;
Shelley, FJ ;
Schwendeman, LJ ;
Donaldson, TK ;
Navalgund, YA .
JOURNAL OF ARTHROPLASTY, 1996, 11 (06) :693-703