Plate fixation of periprosthetic femur fractures: What happens to the cement mantle?

被引:5
作者
Konstantinidis, Lukas [1 ]
Schmidt, Benjamin [2 ]
Bernstein, Anke [1 ]
Hirschmueller, Anja [1 ]
Schroeter, Steffen [3 ]
Suedkamp, Norbert Paul [1 ]
Helwig, Peter [4 ]
机构
[1] Albert Ludwigs Univ Freiburg, Clin Orthopaed & Traumatol, Hugstetter Str. 55, D-79106 Freiburg Im Breisgau, Germany
[2] Univ Hosp Leipzig, Clin Anesthesiol & Intens Care Med, Leipzig, Germany
[3] Eberhard Karls Univ Tubingen, Dept Traumatol & Reconstruct Surg, BG Trauma Ctr Tubingen, Tubingen, Germany
[4] Clin Heidenheim, Clin Orthoped & Traumatol, Heidenheim, Germany
关键词
Biomedical cements; periprosthetic fracture; Total Hip Athroplasty; plate osteosynthesis; angle stable screws; FEMORAL FRACTURES; BONES; HIP; OSTEOSYNTHESIS; MANAGEMENT; FAILURE; STEM;
D O I
10.1177/0954411916682769
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Osteosynthesis of periprosthetic femur fractures by screw fixation around the implanted prosthetic stem is currently regarded as the biomechanically superior option compared with cerclage. The aim of this biomechanical study was damage analysis of the cement mantle after revision screw insertion. A prosthetic stem (Bicontact) was implanted in 20 cadaveric femora in cemented technique. A locking compression plate (Synthes) was then applied to the lateral femur at the level of the prosthetic stem. The method of plate fixation to the femur was assigned randomly to three groups: bicortical non-locking screws, monocortical locking screws, and bicortical locking screws. This was followed by applying a fluctuating axial load (2100N, 0.5Hz) for 20,000 cycles. After testing, macroscopic and microscopic evaluations of the cement mantle were conducted. Cracks formed in the cement mantle in 14% of the 80 screw holes. The type of screw (bicortical or monocortical; locking or non-locking) had no significant effect on the number of cracks (p=0.52). The relationship between manifestation of crack damage and cement mantle thickness was not significant (p=0.36), whereas the relationship between crack formation and screw position was significant (p=0.019). Those screws whose circumference was only partially within the cement mantle yielded a significantly lower number of cracks compared with screws positioned completely within the cement mantle or even touching the prosthetic stem. In order to reduce the incidence of crack formation in the cement mantle during plate osteosynthesis of periprosthetic femur fractures, the screws should not be either placed within the cement mantle or make direct contact with the stem.
引用
收藏
页码:138 / 142
页数:5
相关论文
共 50 条
  • [41] Periprosthetic fractures of the proximal femur: beyond the Vancouver classification
    Stoffel, Karl
    Horn, Tamara
    Zagra, Luigi
    Mueller, Michael
    Perka, Carsten
    Eckardt, Henrik
    EFORT OPEN REVIEWS, 2020, 5 (07) : 449 - 456
  • [42] Periprosthetic Femur Fractures Around a Loose Femoral Stem
    Rozell, Joshua C.
    Donegan, Derek J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 : S10 - S13
  • [43] Extracortical plate fixation with new plate inserts and cerclage wires for the treatment of periprosthetic hip fractures
    Johannes D. Bastian
    Andre Butscher
    Gianni Bigolin
    Matthias A. Zumstein
    Hubert P. Nötzli
    International Orthopaedics, 2014, 38 : 489 - 494
  • [44] Periprosthetic distal femur fractures around total knee replacements: A comprehensive review
    Al-Jabri, Talal
    Ridha, Mohamed
    McCulloch, Robert Allan
    Jayadev, Chethan
    Kayani, Babar
    Giannoudis, Peter, V
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (04): : 1030 - 1038
  • [45] Nail Plate Combination Technique for Native and Periprosthetic Distal Femur Fractures
    Liporace, Frank A.
    Yoon, Richard S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (02) : E64 - E68
  • [46] Intraoperative Periprosthetic Femur Fracture: A Biomechanical Analysis of Cerclage Fixation
    Frisch, Nicholas B.
    Charters, Michael A.
    Sikora-Klak, Jakub
    Banglmaier, Richard F.
    Oravec, Daniel J.
    Silverton, Craig D.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (08) : 1449 - 1457
  • [47] Periprosthetic Hip Fractures With a Loose Stem: Open Reduction and Internal Fixation Versus Stem Revision
    Gonzalez-Martin, David
    Luis Pais-Brito, Jose
    Gonzalez-Casamayor, Sergio
    Guerra-Ferraz, Ayron
    Martin-Velez, Pablo
    Herrera-Perez, Mario
    JOURNAL OF ARTHROPLASTY, 2021, 36 (09) : 3318 - 3325
  • [48] Biomechanical Comparison of 2 Different Locking Plate Fixation Methods in Vancouver B1 Periprosthetic Femur Fractures
    Pletka, Joshua D.
    Marsland, Daniel
    Belkoff, Stephen M.
    Mears, Simon C.
    Kates, Stephen L.
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2011, 2 (02) : 51 - 55
  • [49] Radiographic and Clinical Outcomes of Periprosthetic Distal Femur Fractures Treated With Open Reduction Internal Fixation
    Christ, Alexander B.
    Chawla, Harshvardhan
    Gausden, Elizabeth B.
    Villa, Jordan C.
    Wellman, David S.
    Lorich, Dean G.
    Helfet, David L.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 (10) : 515 - 520
  • [50] Polyaxial locking plate fixation in periprosthetic, peri-implant and distal shaft fractures of the femur : a comparison of open and less invasive surgical approaches
    Hess, Florian
    Knoth, Christoph
    Welter, JoEllen
    Zettl, Ralph
    Doerr, Susanne
    ACTA ORTHOPAEDICA BELGICA, 2020, 86 (01): : 46 - 53