Plate fixation of periprosthetic femur fractures: What happens to the cement mantle?

被引:5
作者
Konstantinidis, Lukas [1 ]
Schmidt, Benjamin [2 ]
Bernstein, Anke [1 ]
Hirschmueller, Anja [1 ]
Schroeter, Steffen [3 ]
Suedkamp, Norbert Paul [1 ]
Helwig, Peter [4 ]
机构
[1] Albert Ludwigs Univ Freiburg, Clin Orthopaed & Traumatol, Hugstetter Str. 55, D-79106 Freiburg Im Breisgau, Germany
[2] Univ Hosp Leipzig, Clin Anesthesiol & Intens Care Med, Leipzig, Germany
[3] Eberhard Karls Univ Tubingen, Dept Traumatol & Reconstruct Surg, BG Trauma Ctr Tubingen, Tubingen, Germany
[4] Clin Heidenheim, Clin Orthoped & Traumatol, Heidenheim, Germany
关键词
Biomedical cements; periprosthetic fracture; Total Hip Athroplasty; plate osteosynthesis; angle stable screws; FEMORAL FRACTURES; BONES; HIP; OSTEOSYNTHESIS; MANAGEMENT; FAILURE; STEM;
D O I
10.1177/0954411916682769
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Osteosynthesis of periprosthetic femur fractures by screw fixation around the implanted prosthetic stem is currently regarded as the biomechanically superior option compared with cerclage. The aim of this biomechanical study was damage analysis of the cement mantle after revision screw insertion. A prosthetic stem (Bicontact) was implanted in 20 cadaveric femora in cemented technique. A locking compression plate (Synthes) was then applied to the lateral femur at the level of the prosthetic stem. The method of plate fixation to the femur was assigned randomly to three groups: bicortical non-locking screws, monocortical locking screws, and bicortical locking screws. This was followed by applying a fluctuating axial load (2100N, 0.5Hz) for 20,000 cycles. After testing, macroscopic and microscopic evaluations of the cement mantle were conducted. Cracks formed in the cement mantle in 14% of the 80 screw holes. The type of screw (bicortical or monocortical; locking or non-locking) had no significant effect on the number of cracks (p=0.52). The relationship between manifestation of crack damage and cement mantle thickness was not significant (p=0.36), whereas the relationship between crack formation and screw position was significant (p=0.019). Those screws whose circumference was only partially within the cement mantle yielded a significantly lower number of cracks compared with screws positioned completely within the cement mantle or even touching the prosthetic stem. In order to reduce the incidence of crack formation in the cement mantle during plate osteosynthesis of periprosthetic femur fractures, the screws should not be either placed within the cement mantle or make direct contact with the stem.
引用
收藏
页码:138 / 142
页数:5
相关论文
共 50 条
  • [31] Revision arthroplasty in periprosthetic fractures of the proximal femur
    Fink, B.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2014, 26 (05): : 455 - 468
  • [32] Optimizing Proximal Fixation in Vancouver B1 Periprosthetic Femur Fractures
    Yevtukh, Alexander
    Taylor, Aaron
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2023, 33 (02)
  • [33] The locking attachment plate for proximal fixation of periprosthetic femur fractures-a biomechanical comparison of two techniques
    Lenz, Mark
    Windolf, Markus
    Mueckley, Thomas
    Hofmann, Gunther O.
    Wagner, Michael
    Richards, Robert G.
    Schwieger, Karsten
    Gueorguiev, Boyko
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (09) : 1915 - 1921
  • [34] Drilling the cement mantle in well-fixed periprosthetic femur fractures is not associated with arthroplasty-related complications
    Noelle L. Van Rysselberghe
    Malcolm R. DeBaun
    Mark Sanchez
    Harsh Wadhwa
    Kayla E. Pfaff
    Michael J. Bellino
    Michael J. Gardner
    Julius A. Bishop
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 1629 - 1633
  • [35] Angulated locking plate in periprosthetic proximal femur fractures: biomechanical testing of a new prototype plate
    Lenz, Mark
    Gueorguiev, Boyko
    Joseph, Steve
    van der Pol, Bas
    Richards, Robert Geoff
    Windolf, Markus
    Schwieger, Karsten
    de Boer, Piet
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (10) : 1437 - 1444
  • [36] Intramedullary Nailing Versus Locked Plate for Treating Supracondylar Periprosthetic Femur Fractures
    Horneff, John G., III
    Scolaro, John A.
    Jafari, S. Mehdi
    Mirza, Amer
    Parvizi, Javad
    Mehta, Samir
    ORTHOPEDICS, 2013, 36 (05) : E561 - E566
  • [37] Nail and Plate Combination Fixation for Periprosthetic and Interprosthetic Fractures
    Yoon, Richard S.
    Patel, Jay N.
    Liporace, Frank A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 : S18 - S20
  • [38] Periprosthetic Femur Fractures
    Ricci, William M.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (03) : 130 - 137
  • [39] Retrograde intramedullary nailing for periprosthetic fractures of the distal femur
    Biber, R.
    Bail, H. J.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2014, 26 (05): : 438 - +
  • [40] Fixation techniques for periprosthetic femur fractures around total knee arthroplasty: a systematic review
    Chan, Peter Y. W.
    Hinkle, Andrew
    Huo, Michael H.
    CURRENT ORTHOPAEDIC PRACTICE, 2024, 35 (04): : 145 - 151