Indoor simulation and testing of photovoltaic thermal (PV/T) air collectors

被引:171
作者
Solanki, S. C. [1 ]
Dubey, Swapnil [1 ]
Tiwari, Arvind [2 ]
机构
[1] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
[2] Univ Twente, Dept Design Prod & Management, NL-7500 AE Enschede, Netherlands
关键词
Hybrid PV/T system; Solar air heater; Thermal efficiency; Electrical efficiency; PERFORMANCE EVALUATION; EXERGY ANALYSIS; SOLAR-SYSTEM; ENERGY; HEATER;
D O I
10.1016/j.apenergy.2009.03.013
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An indoor standard test procedure has been developed for thermal and electrical testing of PV/T collectors connected in series. For this, a PV/T solar air heater has been designed, fabricated and its performance over different operating parameters were studied. Based on the energy balance equations, in a steady state condition, a thermal model has been developed. Comparison between experimental and theoretical results were also been carried out. The thermal and electrical efficiency of the solar heater is 42% and 8.4%, respectively. This test procedure can be used by manufacturers for testing of different types of PV modules in order to optimize its products. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2421 / 2428
页数:8
相关论文
共 20 条
[1]   STUDY OF A HYBRID SOLAR-SYSTEM SOLAR AIR HEATER COMBINED WITH SOLAR-CELLS [J].
BHARGAVA, AK ;
GARG, HP ;
AGARWAL, RK .
ENERGY CONVERSION AND MANAGEMENT, 1991, 31 (05) :471-479
[2]   Energy and exergy analysis of photovoltaic-thermal collector with and without glass cover [J].
Chow, T. T. ;
Pei, G. ;
Fong, K. F. ;
Lin, Z. ;
Chan, A. L. S. ;
Ji, J. .
APPLIED ENERGY, 2009, 86 (03) :310-316
[3]   Building-integrated photovoltaic and thermal applications in a subtropical hotel building [J].
Chow, TT ;
Hand, JW ;
Strachan, PA .
APPLIED THERMAL ENGINEERING, 2003, 23 (16) :2035-2049
[4]   DESIGN CONSIDERATIONS FOR FLAT-PLATE-PHOTOVOLTAIC THERMAL COLLECTORS [J].
COX, CH ;
RAGHURAMAN, P .
SOLAR ENERGY, 1985, 35 (03) :227-241
[5]   Analysis of different configurations of flat plate water collectors connected in series [J].
Dubey, Swapnil ;
Tiwari, G. N. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (14) :1362-1372
[6]   Analytical expression for electrical efficiency of PV/T hybrid air collector [J].
Dubey, Swapnil ;
Sandhu, G. S. ;
Tiwari, G. N. .
APPLIED ENERGY, 2009, 86 (05) :697-705
[7]  
Duffle J.A., 1991, SOLAR ENG THERMAL PR
[8]   SIMPLIFIED METHOD FOR PREDICTING PHOTO-VOLTAIC ARRAY OUTPUT [J].
EVANS, DL .
SOLAR ENERGY, 1981, 27 (06) :555-560
[9]   Conventional hybrid photovoltaic/thermal (PV/T) air heating collectors: Steady-state simulation [J].
Garg, HP ;
Adhikari, RS .
RENEWABLE ENERGY, 1997, 11 (03) :363-385
[10]   EXPERIMENTAL-STUDY ON A HYBRID PHOTOVOLTAIC THERMAL SOLAR WATER-HEATER AND ITS PERFORMANCE PREDICTIONS [J].
GARG, HP ;
AGARWAL, RK ;
JOSHI, JC .
ENERGY CONVERSION AND MANAGEMENT, 1994, 35 (07) :621-633