摘要
Internal fixation of distal radius fractures allows early functional mobilization with a decreased risk of residual functional deficits. Plate fixation in distal radius fractures is associated with an increased risk of tendon irritation or ruptures due to the interactions between the relatively bulky implant and the adjacent tendons and tendon sheaths. Implants made of bioresorbable materials would make implant removal unnecessary. Two main questions have to be answered before bioresorbable implants can be used clinically in this indication. Question 1. Are implants made of existing bioresorbable materials able to transmit the required loads during fracture healing and what design is needed? Question 2. What is the response of the adjacent tissue during degradation? In order to begin providing answers to these questions we have undertaken the following activities: A new device based on the capacitive sensor technology of novel Gmbh, Munich, Germany, was developed in order to measure the amount of force transmitted across the radio-ulno-carpal joint in vivo under unloaded conditions. A study was performed with the aim of building a Finite Element Model (FEM) which could be utilized in future studies to optimize the design of a resorbable implant system in the treatment of distal radius fractures. A large animal model was established to investigate the in-vivo reactions of different tissue types during implant degradation.
引用
收藏
页码:77 / 83
页数:7
相关论文
共 31 条
[1]   FORCES IN THE NORMAL AND ABNORMAL HAND [J].
AN, KN ;
CHAO, EY ;
COONEY, WP ;
LINSCHEID, RL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1985, 3 (02) :202-211
[2]   Basic epidemiology of fractures of the upper and lower limb among Americans over 65 years of age [J].
Baron, JA ;
Karagas, M ;
Barrett, J ;
Kniffin, W ;
Malenka, D ;
Mayor, M ;
Keller, RB .
EPIDEMIOLOGY, 1996, 7 (06) :612-618
[3]   FOREIGN-BODY REACTIONS TO RESORBABLE POLY(L-LACTIDE) BONE PLATES AND SCREWS USED FOR THE FIXATION OF UNSTABLE ZYGOMATIC FRACTURES [J].
BERGSMA, EJ ;
ROZEMA, FR ;
BOS, RRM ;
DEBRUIJN, WC .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (06) :666-670
[4]   Routine implant removal after fracture surgery: A potentially reducible consumer of hospital resources in trauma units [J].
Bostman, O ;
Pihlajamaki, H .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1996, 41 (05) :846-849
[5]   Open reduction and internal fixation of intra articular and unstable fractures of the distal radius using the AO distal radius plate [J].
Campbell, DA .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (06) :528-534
[6]   Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures [J].
Carter, PR ;
Frederick, HA ;
Laseter, GF .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (02) :300-307
[7]   Resorbable device for fracture fixation: In vivo degradation and mechanical behaviour [J].
Fini, M ;
Giannini, S ;
Giardino, R ;
Giavaresi, G ;
Grimaldi, M ;
Aldini, NN ;
Orienti, L ;
Rocca, M .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1995, 18 (12) :772-776
[8]   Outcome of distal radial fractures in young adults [J].
Gliatis, JD ;
Plessas, SJ ;
Davis, TRC .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (06) :535-543
[9]  
Goh S. H., 1996, Annals Academy of Medicine Singapore, V25, P547
[10]   Internal fixation of distal radius fractures with dorsal dislocation:: π-plate or two 1/4 tube plates?: A prospective randomized study [J].
Hahnloser, D ;
Platz, A ;
Amgwerd, M ;
Trentz, O .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1999, 47 (04) :760-765