Automatic measurement and warning of tension force reduction in a PT tendon using eddy current sensing

被引:24
作者
Kim, Ji-Min [1 ]
Lee, Jun [1 ]
Sohn, Hoon [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Civil & Environm Engn, Daejeon 34141, South Korea
关键词
Post-tensioning tendon; Pre-stressing strand; Tension force loss; Eddy current measurement; Nondestructive testing and evaluation; Low power inspection; SENSORS; PRESTRESS;
D O I
10.1016/j.ndteint.2017.02.002
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Post-tensioning (PT) using a bundle of pre-stressed strands is a critical process for assembling pre-fabricated and modularized bridge members. However, the tension force gradually diminishes over time due to such factors as corrosion, creep, and steel relaxation. Such changes compromise the overall safety of such structures. In this study, an eddy-current-based tension-force-loss warning (EC-TFLW) technique is proposed to detect and warn automatically of excessive loss of tension force in a PT tendon. A ring-type eddy-current sensor (ECS) is mounted on the outer surface of a wedge holding a tendon, and the level of eddy current measured by the ECS is related to the tension force of the tendon. The advantages of the proposed technique include: (1) low power consumption, (2) low cost, (3) simple installation, and (4) automated warning. The performance of the proposed EC-TFLW technique was validated experimentally in a full-scale lab test of a 3.3-m long, 15.2-mm diameter, mono-strand tendon that was tensioned using a universal testing machine (from 20 to 180 kN). Statistical hypothesis testing using the chi-square distribution was applied to the measured eddy current signals, and if the decline in tension exceeded a certain level, a warning was sent out automatically.
引用
收藏
页码:93 / 99
页数:7
相关论文
共 20 条
[1]   Wire Breakage Detection Using Relative Strain Variation in Unbonded Posttensioning Anchors [J].
Abdullah, A. B. M. ;
Rice, Jennifer A. ;
Hamilton, H. R. .
JOURNAL OF BRIDGE ENGINEERING, 2015, 20 (01)
[2]  
ASTM, 2006, STAND SPEC STEEL STR, pA416
[3]   Use of Interwire Ultrasonic Leakage to Quantify Loss of Prestress in Multiwire Tendons [J].
Bartoli, Ivan ;
Salamone, Salvatore ;
Phillips, Robert ;
di Scalea, Francesco Lanza ;
Sikorsky, Charles S. .
JOURNAL OF ENGINEERING MECHANICS, 2011, 137 (05) :324-333
[4]  
Berenson M.L., 2009, BASIC BUSINESS STAT, V11th
[5]   THEORY OF MAGNETOELASTIC EFFECTS IN FERROMAGNETISM [J].
BROWN, WF .
JOURNAL OF APPLIED PHYSICS, 1965, 36 (3P2) :994-&
[6]  
Cederquist SC, 2000, MATER PERFORMANCE, V39, P18
[7]   MAGNETOMECHANICAL COUPLING IN BRIDGMAN-GROWN TB0.3DY0.7FE1.9 AT HIGH DRIVE LEVELS [J].
CLARK, AE ;
TETER, JP ;
WUNFOGLE, M ;
MOFFETT, M ;
LINDBERG, J .
JOURNAL OF APPLIED PHYSICS, 1990, 67 (09) :5007-5009
[8]  
Kim J. W., 2015, ADV STRUCT ENG MECH
[9]   FBG Sensors Encapsulated into 7-Wire Steel Strand for Tension Monitoring of a Prestressing Tendon [J].
Kim, Jae-Min ;
Kim, Hyun-Woo ;
Park, Young-Ha ;
Yang, In-Hwan ;
Kim, Young-Sang .
ADVANCES IN STRUCTURAL ENGINEERING, 2012, 15 (06) :907-917
[10]   Magnetoelastic effect during the low-temperature deformation of 316LN-IG stainless steel [J].
Krivykh, A. V. ;
Irodova, A. V. ;
Keilin, V. E. .
TECHNICAL PHYSICS, 2015, 60 (01) :72-78