Potentiometric biosensing of proteins with ultrasensitive ion-selective microelectrodes and nanoparticle labels

被引:121
作者
Chumbimuni-Torres, Karin Y.
Dai, Zong
Rubinova, Nastassia
Xiang, Yun
Pretsch, Erno [1 ]
Wang, Joseph
Bakker, Eric
机构
[1] ETH, Organ Chem Lab, CH-8093 Zurich, Switzerland
[2] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[3] Arizona State Univ, Biodesign Inst, Tempe, AZ 85287 USA
[4] Arizona State Univ, Fulton Sch Engn, Tempe, AZ 85287 USA
关键词
D O I
10.1021/ja065899k
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We report here for the first time on the use of potentiometry for ultrasensitive nanoparticle-based detection of protein interactions. A silver ion-selective microelectrode is used to detect silver ions oxidatively released from silver enlarged gold nanoparticle labels in a sandwich immunoassay. Since potentiometry is expected to largely maintain its analytical characteristics upon reducing the sample volume, it is anticipated that this approach may form the basis for bioassays with attractive detection limits. Copyright © 2006 American Chemical Society.
引用
收藏
页码:13676 / 13677
页数:2
相关论文
共 16 条
  • [1] Rational design of potentiometric trace level ion sensors.: A Ag+-selective electrode with a 100 ppt detection limit
    Ceresa, A
    Radu, A
    Peper, S
    Bakker, E
    Pretsch, E
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (16) : 4027 - 4036
  • [2] Solid contact potentiometric sensors for trace level measurements
    Chumbimuni-Torres, KY
    Rubinova, N
    Radu, A
    Kubota, LT
    Bakker, E
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (04) : 1318 - 1322
  • [3] An electrochemical metalloimmunoassay based on a colloidal gold label
    Dequaire, M
    Degrand, C
    Limoges, B
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (22) : 5521 - 5528
  • [4] MCM-41 mesoporous material modified carbon paste electrode for the determination of cardiac troponin I by anodic stripping voltammetry
    Guo, HS
    He, NY
    Ge, SX
    Yang, D
    Zhang, JN
    [J]. TALANTA, 2005, 68 (01) : 61 - 66
  • [5] HENN RW, 1977, NEBLETTES HDB PHOTOG, P114
  • [6] Electrochemical coding for multiplexed immunoassays of proteins
    Liu, GD
    Wang, J
    Kim, J
    Jan, MR
    Collins, GE
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (23) : 7126 - 7130
  • [7] Potentiometry at trace levels in confined samples: Ion-selective electrodes with subfemtomole detection limits
    Malon, Adam
    Vigassy, Tamas
    Bakker, Eric
    Pretsch, Erno
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (25) : 8154 - 8155
  • [8] Effect of transmembrane electrolyte diffusion on the detection limit of carrier-based potentiometric ion sensors
    Mathison, S
    Bakker, E
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (02) : 303 - 309
  • [9] RUBINOVA N, IN PRESS SENS ACTU B
  • [10] Sonically assisted electroanalytical detection of ultratrace arsenic
    Simm, AO
    Banks, CE
    Compton, RG
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (17) : 5051 - 5055