Analytical reconstruction for helical cone-beam SPECT with non-uniform attenuation correction

被引:0
|
作者
Huang, Qiu [1 ]
Zeng, Gengsheng L. [1 ]
Gullberg, Grant T. [1 ]
机构
[1] Univ Utah, UCAIR, Dept Radiol, Salt Lake City, UT 84108 USA
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper concerns image reconstruction for helical cone-beam (CB) single photon emission computed tomography (SPECT) with compensation of non-uniform attenuation. We present a filtering-backprojection-filtering algorithm of the FDK type by extending the FBP algorithms for attenuated fan-beam projections to the three-dimensional (3D) cone-beam projections. Each transaxial slice can be reconstructed from attenuated projection data acquired along a specific 2 pi segment of the helix. CB artifacts are less for smaller pitch of the heical trajectory. The algorithm is validated by numerical results for a simulated Shepp-Logan-like phantom and the Defrise phantom.
引用
收藏
页码:1856 / 1859
页数:4
相关论文
共 50 条
  • [1] Analytical Cone Beam SPECT Reconstruction with Non-uniform Attenuation
    Wen, Junhai
    Chen, Yunbin
    Wang, Li
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2136 - 2139
  • [2] Analytical fan-beam and cone-beam reconstruction algorithms with uniform attenuation correction for SPECT
    Tang, QL
    Zeng, GSL
    Gullberg, GT
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (13): : 3153 - 3170
  • [3] Analytical cone-beam SPECT reconstruction algorithm with non-uniform attenuation for general non-circular orbit
    Wen, Junhai
    Zhang, Kangping
    Li, Cuifen
    Liang, Zhengrong
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (09) : 1221 - 1233
  • [4] Effect of de-noising and DDRV correction on cone-beam SPECT reconstruction with non-uniform attenuation
    Zhang, Hao
    Wen, Junhai
    Yin, Wen
    Li, Cuifen
    Zhang, Kangping
    Liang, Zhengrong
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [5] Analytical solution to Cone-beam SPECT reconstruction with non-uniform attenuation and distance-dependent resolution variation
    Zhang, Hao
    Wen, Junhai
    Yang, Jing
    Hu, Peng
    Liang, Zhengrong
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [6] Analytical algorithm for 3D cone-beam SPECT reconstruction with uniform attenuation correction
    Bronnikov, A.V.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 3 : 1417 - 1423
  • [7] Rebinning Methods for Cone Beam SPECT Reconstruction with Non-uniform Attenuation
    Chen, Yunbin
    Wen, Junhai
    Wang, Li
    Hu, Peng
    Zhang, Hao
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 337 - 340
  • [8] Analytical fan-beam and cone-beam reconstruction algorithms with uniform attenuation correction
    Tang, QL
    Zeng, GL
    Gullberg, GT
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3546 - 3550
  • [9] Minimal residual cone-beam reconstruction with attenuation correction in SPECT
    La, V
    Grangeat, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04): : 715 - 727
  • [10] A RECONSTRUCTION ALGORITHM FOR HELICAL CONE-BEAM SPECT
    WENG, Y
    ZENG, GL
    GULLBERG, GT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 1092 - 1101