A Time-domain Characterization Method for UHF Partial Discharge Sensors

被引:10
|
作者
Chen, Xiaoxin [1 ]
Qian, Yong [1 ]
Sheng, Gehao [1 ]
Jiang, Xiuchen [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Elect Engn, Shanghai 200240, Peoples R China
关键词
UHF sensors; partial discharges; time domain measurements; sensor characterization; deconvolution; filters; directivity; ANTENNA; DECONVOLUTION; OPTIMIZATION; CRITERION;
D O I
10.1109/TDEI.2016.005965
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The performance of ultra-high frequency (UHF) sensors has a significant impact on the accuracy of UHF partial discharge (PD) detection. In this paper, a method is presented for the time-domain characterization of UHF sensors to provide a comprehensive evaluation of their performance in the time domain. The peak envelope value and the envelope width are adopted in the method as two characterization parameters for predicting the output waveforms of UHF sensors. However, due to the ill-posedness of deconvolution, the measurement of these parameters is highly sensitive to noise. Therefore, an automated optimization scheme is devised based on the multi-parameter filter technique to solve the problem. Two UHF sensors are then investigated using the proposed method. The measured characterization parameters are found to be dependent on the orientation of the sensors, which is discussed from the perspective of sensor geometry. Further, PD experiments are carried out using the same UHF sensors to validate the method. The actual performances of the sensors are in good agreement with their time-domain characterization parameters. The proposed method would be complementary to existing frequency-domain characterization methods and is useful for the comparison of different UHF sensors, especially when their output waveforms are utilized for PD detection.
引用
收藏
页码:110 / 119
页数:10
相关论文
共 50 条
  • [31] Estimation of Time Difference Between Partial Discharge UHF Signals Using Differential Energy Method
    Zhu, Ming-Xiao
    Xue, Jian-Yi
    Zhang, Jia-Ning
    Deng, Jun-Bo
    Mu, Hai-Bao
    Zhang, Guan-Jun
    Guo, An-Xiang
    Liu, Xiao-Wei
    2015 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2015,
  • [32] Optimal Placement of UHF Sensors for Accurate Localization of Partial Discharge Source in GIS
    Liang, Rui
    Wu, Shenglei
    Chi, Peng
    Peng, Nan
    Li, Yi
    ENERGIES, 2019, 12 (06):
  • [33] GIS partial discharge quantitative measurements using UHF microstrip antenna sensors
    Tang Ju
    Xu Zhongrong
    Zhang Xiaoxing
    Sun Caixin
    2007 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2007, : 116 - 119
  • [34] Application of UHF Sensors in Power System Equipment for Partial Discharge Detection: A Review
    Chai, Hua
    Phung, B. T.
    Mitchell, Steve
    SENSORS, 2019, 19 (05)
  • [35] Localisation of Partial Discharge source through Delay calculation using UHF sensors
    Anitha, Bhukya
    Mishra, Dipak Kumar
    Koley, Chiranjib
    2017 IEEE INTERNATIONAL WIE CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (IEEE WIECON-ECE 2017), 2017, : 172 - 175
  • [36] Detection of Partial Discharge Sources Using UHF Sensors and Blind Signal Separation
    Boya, Carlos
    Robles, Guillermo
    Parrado-Hernandez, Emilio
    Ruiz-Llata, Marta
    SENSORS, 2017, 17 (11):
  • [37] Development of UHF Transformer Probe Sensors for On-Line Partial Discharge Measurement
    Reid, Alistair
    Judd, Martin
    Johnstone, Carl
    UPEC: 2009 44TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, 2009, : 40 - +
  • [38] Experimental research of UHF method for the detection of partial discharge in GIS
    Shao, T.
    Zhou, W.J.
    Zhu, Y.F.
    Wu, S.H.
    Gaodianya Jishu/High Voltage Engineering, 2001, 27 (03):
  • [39] A Novel Error Correction Method for UHF Partial Discharge Localization
    Liu, Hong-jing
    Chen, Jing-de
    Luo, Lin-gen
    Li, Wei
    Ren, Zhi-gang
    Sheng, Ge-hao
    2016 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND AUTOMATION (ICEEA 2016), 2016,
  • [40] Study on the monitoring technique of partial discharge of GIS by UHF method
    2005, Xi'an High Voltage Apparatus Research Institute, Beijing, China (41):