Influence of Single-file Endodontics on Apical Transportation in Curved Root Canals: An Ex Vivo Micro-Computed Tomographic Study

被引:23
|
作者
Junaid, Alanna [1 ]
Freire, Laila Gonzales [2 ]
da Silveira Bueno, Carlos Eduardo [3 ]
Mello, Isabel [4 ]
Cunha, Rodrigo Sanches [4 ]
机构
[1] Univ Manitoba, Winnipeg, MB R3E 0W2, Canada
[2] Univ Sao Paulo, Sao Paulo, Brazil
[3] Sao Leopoldo Mand, Dent Res Ctr, Campinas, SP, Brazil
[4] Univ Manitoba, Dept Restorat Dent, Winnipeg, MB R3E 0W2, Canada
关键词
Continuous rotating motion; micro-computed tomography; reciprocating motion; root canal preparation; transportation; NICKEL-TITANIUM ALLOY; CYCLIC FATIGUE LIFE; TWISTED FILES; MECHANICAL-PROPERTIES; SHAPING ABILITY; PROTAPER SYSTEM; ROTARY; INSTRUMENTS; PROFILE;
D O I
10.1016/j.joen.2013.09.021
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: More information regarding the ability of single files to maintain the original canal position is required before adopting a single-file approach to cleaning and shaping. This study compares apical transportation in curved root canals when instrumenting with a single Wave One (WO) file (Dentsply Tulsa Dental Specialties, Tulsa, OK) in a reciprocating motion with that incurred when using a sequence of Twisted Files (TFs; SybronEndo, Orange, CA) in a continuous rotating motion. Methods: Forty mesial canals of mandibular molars were evenly allocated into 2 balanced groups (n=20) with a 17-mm average canal length and 200 average curvature. Canals were accessed in a conventional manner and instrumentation was completed. with a single WO file or a series of TFs. The canals were instrumented according to the manufacturers' protocol: Apical transportation was assessed on a comparison of the pre- and postinstrumentation micro computed tomographic scans at 1-, 2-, 3-, 4-, and 5-mm sections. One-way analysis of variance was performed to assess if a significant difference between systems exists. Results: No significant difference (P>.05) was found between the WO and TF groups. Transportation in the mesial direction was of greater magnitude than distal transportation for both files systems. The mean transportation in the mesial direction was 100.1 +/- 8.8 mu m (WO group) and 101.0 +/- 10.9 mu m (TF group) (P=.5), whereas distal transportation was found to be 80.9 +/- 14.6 mu m (WO group) and 60.3 +/- 11.0 mu m (TF group) (P=.3). Conclusions: The results suggest that no difference exists between the WO file system and the conventional multifile TF system when considering apical transportation in curved canals.
引用
收藏
页码:717 / 720
页数:4
相关论文
共 50 条
  • [41] Efficacy of Reciprocating Instruments for Removing Filling Material in Curved Canals Obturated with a Single-cone Technique: A Micro-computed Tomographic Analysis
    Fruchi, Lincoln de Campos
    Ordinola-Zapata, Ronald
    Cavenago, Bruno Cavalini
    Hungaro Duarte, Marco Antonio
    da Silveira Bueno, Carlos Eduardo
    De Martin, Alexandre Sigrist
    JOURNAL OF ENDODONTICS, 2014, 40 (07) : 1000 - 1004
  • [42] Efficiency of Different Nickel-Titanium Endodontic File Systems in Cleaning and Apical Transportation of Simulated Curved Root Canals
    Ivacson, Andrea Csinszka Kovacs
    Pacurar, Mariana
    Monea, Monica
    Kovacs, Monika
    Pop, M.
    Bechir, Anamaria
    Borda, Angela
    REVISTA DE CHIMIE, 2017, 68 (05): : 957 - 961
  • [43] Cone-beam Computed Tomographic and Micro-computed Tomographic Evaluations of the Root Apexes of Teeth with Posttreatment Apical Periodontitis
    Villa-Machado, Paula A.
    Restrepo-Patino, Diana M.
    Calvo-Trejos, Juliana P.
    Restrepo-Restrepo, Felipe A.
    Tobon-Arroyave, Sergio, I
    Provenzano, Jose C.
    Siqueira, Jose F., Jr.
    Alves, Flavio R. F.
    JOURNAL OF ENDODONTICS, 2020, 46 (11) : 1695 - 1701
  • [44] Assessment of Mechanical Root Canal Preparation with Centric Reciprocating or Eccentric Rotary Kinematics: A Micro-computed Tomographic Study
    Fonseca Fernandes, Priscilla Oliveira
    Freire, Laila Gonzales
    Iglecias, Elaine Faga
    Vieira, Basilio Rodrigues
    Zuolo, Mario Luis
    Gavini, Giulio
    JOURNAL OF ENDODONTICS, 2020, 46 (09) : 1309 - 1316
  • [45] Micro-computed Tomographic Analysis of Mandibular Second Molars with C-shaped Root Canals
    Amoroso-Silva, Pablo Andres
    Ordinola-Zapata, Ronald
    Hungaro Duarte, Marco Antonio
    Gutmann, James L.
    del Carpio-Perochena, Aldo
    Bramante, Clovis Monteiro
    de Moraes, Ivaldo Gomes
    JOURNAL OF ENDODONTICS, 2015, 41 (06) : 890 - 895
  • [46] Microcomputed Assessment of Transportation, Centering Ratio, Canal Area, and Volume Increase after Single-file Rotary and Reciprocating Glide Path Instrumentation in Curved Root Canals: A Laboratory Study
    Aydin, Zeliha Ugur
    Keskin, Neslihan Busra
    Ozyurek, Taha
    Geneci, Ferhat
    Ocak, Mert
    Celik, Hakan Hamdi
    JOURNAL OF ENDODONTICS, 2019, 45 (06) : 791 - 796
  • [47] Determination of the Initial Apical Canal Diameter by the First File to Bind or Cone-beam Computed Tomographic Measurements Using Micro-computed Tomography as the Gold Standard: An Ex Vivo Study in Human Cadavers
    Campello, Andrea F.
    Marceliano-Alves, Marilia F.
    Siqueira, Jose F., Jr.
    Marques, Fabio V.
    Guedes, Fabio R.
    Lopes, Ricardo T.
    Alvarenga, Fabricia O.
    Alves, Flavio R. F.
    JOURNAL OF ENDODONTICS, 2019, 45 (05) : 619 - 622
  • [48] Micro-computed tomographic evaluation of dentinal microcracks in response to progressive taper enlargement in root canals of maxillary molars
    de Lima, Carolina Oliveira
    de Montan, Julia Brito de Moura
    Barbosa, Ana Flavia Almeida
    Antunes, Bernardo Rempto
    Lacerda, Mariane Floriano Lopes Santos
    Sassone, Luciana Moura
    Versiani, Marco Aurelio
    Silva, Emmanuel Joao Nogueira Leal
    INTERNATIONAL ENDODONTIC JOURNAL, 2025, 58 (02) : 357 - 362
  • [49] A Micro-computed Tomographic Evaluation of the Accuracy of 3 Electronic Apex Locators in Curved Canals of Mandibular Molars
    Piasecki, Lucila
    dos Reis, Paulo Jose
    Jussiani, Eduardo Inocente
    Andrello, Avacir Casanova
    JOURNAL OF ENDODONTICS, 2018, 44 (12) : 1872 - 1877
  • [50] Shaping ability of non-adaptive and adaptive core nickel-titanium single-file systems with supplementary file in ribbon-shaped canals analysed by micro-computed tomography
    Chinchiyanont, Parichat
    Yanpiset, Kallaya
    Banomyong, Danuchit
    Thongbai-On, Nathamon
    AUSTRALIAN ENDODONTIC JOURNAL, 2023, 49 (01) : 38 - 47