Anterior thoracic spine reconstruction using a titanium mesh cage and pedicled rib flap

被引:10
|
作者
O'Shaughnessy, Brian A.
Ondra, Stephen L.
Ganju, Aruna
Said, Hakim K.
Few, Julius W.
Liu, John C.
机构
[1] Northwestern Univ, Dept Neurol Surg, Feinberg Sch Med, McGaw Med Ctr, Chicago, IL 60611 USA
[2] Northwestern Univ, Div Plast & Reconstruct Surg, Feinberg Sch Med, McGaw Med Ctr, Chicago, IL 60611 USA
关键词
osteomyelitis; spine metastases; thoracic spine; titanium mesh cage; vascularized graft;
D O I
10.1097/01.brs.0000226017.28265.a6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A retrospective clinical study. Objectives. To evaluate the safety and efficacy of using an integrated titanium mesh cage and pedicled rib flap for thoracic spine reconstruction in patients at high risk of pseudarthrosis. Summary of Background Data. A variety of materials are available for interbody thoracic reconstruction; however, the optimal treatment of patients at high risk of pseudarthrosis remains a challenging problem. Free or pedicled bone flaps have been shown to be highly effective in terms of promoting fusion and titanium mesh cages provide excellent structural support. Methods. Eleven patients who underwent anterior thoracic corpectomy and spinal reconstruction using an integrated titanium mesh cage and pedicled rib flap were analyzed with a mean follow-up of 37 months ( range, 25-55 months). The etiology of spinal disease was infection in 7 (64%) patients and tumor in the remaining 4 (36%) patients. Seven ( 64%) patients were treated with only an anterior approach while the remaining 4 ( 36%) patients underwent circumferential spinal reconstruction. Results. All patients demonstrated clinical and radiographic evidence of spinal fusion at the time of follow-up. All patients had stable or improved Frankel grades after surgery. There was a mean kyphosis correction of 7 for both the focal and regional thoracic kyphosis. There were three significant postoperative complications: bilateral pleural effusion, gram-negative bacteremia, and transient right lower extremity weakness requiring reoperation and pedicle screw revision. Two patients died after surgery: one from aneurysmal subarachnoid hemorrhage and the other from complications of breast cancer. Conclusions. The use of an integrated rib flap and titanium mesh cage construct appears to be a safe and effective means of providing immediate and substantial anterior column support as well as achieving arthrodesis in challenging fusion candidates.
引用
收藏
页码:1820 / 1827
页数:8
相关论文
共 50 条
  • [31] The efficiency of the posterior-only approach using shaped titanium mesh cage for the surgical treatment of spine tuberculosis in children: A preliminary study
    Zhang, Hongqi
    Guo, Qiang
    Wang, Yunjia
    Guo, Chaofeng
    Tang, Mingxing
    JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (03):
  • [32] Anterior decompression and hybrid reconstruction with titanium mesh cage plus plate and self-locking stand-alone cage for the treatment of three-level cervical spondylotic myelopathy
    Zhou, Jian
    Li, Xilei
    Zhou, Xiaogang
    Lin, Hong
    Dong, Jian
    JOURNAL OF CLINICAL NEUROSCIENCE, 2017, 43 : 196 - 201
  • [33] The transmission of stress to grafted bone inside a titanium mesh cage used in anterior column reconstruction after total spondylectomy: A finite-element analysis
    Akamaru, T
    Kawahara, N
    Sakamoto, J
    Yoshida, A
    Murakami, H
    Hato, T
    Awamori, S
    Oda, J
    Tomita, K
    SPINE, 2005, 30 (24) : 2783 - 2787
  • [34] Early failures following cervical corpectomy reconstruction with titanium mesh cages and anterior plating
    Daubs, MD
    SPINE, 2005, 30 (12) : 1402 - 1406
  • [35] PEEK vs Titanium Cage for Anterior Column Reconstruction in Active Spinal Tuberculosis: A Comparative Study
    Goyal, Nikhil
    Ahuja, Kaustubh
    Yadav, Gagandeep
    Gupta, Tushar
    Ifthekar, Syed
    Kandwal, Pankaj
    NEUROLOGY INDIA, 2021, 69 (04) : 966 - 972
  • [36] Scoliosis instrumentation alters primary and coupled motions of the spine: An in vitro study using entire thoracolumbar spine and rib cage specimens
    Liebsch, Christian
    Obid, Peter
    Vogt, Morten
    Schlager, Benedikt
    Wilke, Hans-Joachim
    JOR SPINE, 2024, 7 (04):
  • [37] Single posterior approach for circumferential decompression and anterior reconstruction using cervical trabecular metal mesh cage in patients with metastatic spinal tumour
    Chiu, Yen-Chun
    Yang, Shih-Chieh
    Kao, Yu-Hsien
    Tu, Yuan-Kun
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2015, 13
  • [38] Comparison of anterior cervical fusion by titanium mesh cage versus nano-hydroxyapatite/polyamide cage following single-level corpectomy
    Yang, Xi
    Chen, Qi
    Liu, Limin
    Song, Yueming
    Kong, Qingquan
    Zeng, Jiancheng
    Xue, Youdi
    Ren, Chunpeng
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (12) : 2421 - 2427
  • [39] Risk factors for subsidence of titanium mesh cage following single-level anterior cervical corpectomy and fusion
    Chengyue Ji
    Shunzhi Yu
    Ning Yan
    Jiaxing Wang
    Fang Hou
    Tiesheng Hou
    Weihua Cai
    BMC Musculoskeletal Disorders, 21
  • [40] Risk factors for subsidence of titanium mesh cage following single-level anterior cervical corpectomy and fusion
    Ji, Chengyue
    Yu, Shunzhi
    Yan, Ning
    Wang, Jiaxing
    Hou, Fang
    Hou, Tiesheng
    Cai, Weihua
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)