Anterior thoracic spine reconstruction using a titanium mesh cage and pedicled rib flap

被引:10
|
作者
O'Shaughnessy, Brian A.
Ondra, Stephen L.
Ganju, Aruna
Said, Hakim K.
Few, Julius W.
Liu, John C.
机构
[1] Northwestern Univ, Dept Neurol Surg, Feinberg Sch Med, McGaw Med Ctr, Chicago, IL 60611 USA
[2] Northwestern Univ, Div Plast & Reconstruct Surg, Feinberg Sch Med, McGaw Med Ctr, Chicago, IL 60611 USA
关键词
osteomyelitis; spine metastases; thoracic spine; titanium mesh cage; vascularized graft;
D O I
10.1097/01.brs.0000226017.28265.a6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A retrospective clinical study. Objectives. To evaluate the safety and efficacy of using an integrated titanium mesh cage and pedicled rib flap for thoracic spine reconstruction in patients at high risk of pseudarthrosis. Summary of Background Data. A variety of materials are available for interbody thoracic reconstruction; however, the optimal treatment of patients at high risk of pseudarthrosis remains a challenging problem. Free or pedicled bone flaps have been shown to be highly effective in terms of promoting fusion and titanium mesh cages provide excellent structural support. Methods. Eleven patients who underwent anterior thoracic corpectomy and spinal reconstruction using an integrated titanium mesh cage and pedicled rib flap were analyzed with a mean follow-up of 37 months ( range, 25-55 months). The etiology of spinal disease was infection in 7 (64%) patients and tumor in the remaining 4 (36%) patients. Seven ( 64%) patients were treated with only an anterior approach while the remaining 4 ( 36%) patients underwent circumferential spinal reconstruction. Results. All patients demonstrated clinical and radiographic evidence of spinal fusion at the time of follow-up. All patients had stable or improved Frankel grades after surgery. There was a mean kyphosis correction of 7 for both the focal and regional thoracic kyphosis. There were three significant postoperative complications: bilateral pleural effusion, gram-negative bacteremia, and transient right lower extremity weakness requiring reoperation and pedicle screw revision. Two patients died after surgery: one from aneurysmal subarachnoid hemorrhage and the other from complications of breast cancer. Conclusions. The use of an integrated rib flap and titanium mesh cage construct appears to be a safe and effective means of providing immediate and substantial anterior column support as well as achieving arthrodesis in challenging fusion candidates.
引用
收藏
页码:1820 / 1827
页数:8
相关论文
共 50 条
  • [21] The use of titanium surgical mesh-bone graft composite in the anterior thoracic or lumbar spine after complete or partial corpectomy
    Bhat, AL
    Lowery, GL
    Sei, A
    EUROPEAN SPINE JOURNAL, 1999, 8 (04) : 304 - 309
  • [22] The effects of titanium mesh cage size on the biomechanical responses of cervical spine after anterior cervical corpectomy and fusion: A finite element study
    Zhou, Enze
    Huang, Huiwen
    Zhao, Yanbin
    Wang, Lizhen
    Fan, Yubo
    CLINICAL BIOMECHANICS, 2022, 91
  • [23] The effect of follower load on the intersegmental coupled motion characteristics of the human thoracic spine: An in vitro study using entire rib cage specimens
    Liebsch, Christian
    Graf, Nicolas
    Wilke, Hans-Joachim
    JOURNAL OF BIOMECHANICS, 2018, 78 : 36 - 44
  • [24] Long-term outcomes of the nano-hydroxyapatite/polyamide-66 cage versus the titanium mesh cage for anterior reconstruction of thoracic and lumbar corpectomy: a retrospective study with at least 7 years of follow-up
    Hu, Bowen
    Wang, Liang
    Song, Yueming
    Yang, Xi
    Liu, Limin
    Zhou, Chunguang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [25] Long-term outcomes of the nano-hydroxyapatite/polyamide-66 cage versus the titanium mesh cage for anterior reconstruction of thoracic and lumbar corpectomy: a retrospective study with at least 7 years of follow-up
    Bowen Hu
    Liang Wang
    Yueming Song
    Xi Yang
    Limin Liu
    Chunguang Zhou
    Journal of Orthopaedic Surgery and Research, 18
  • [26] In vitro comparison of personalized 3D printed versus standard expandable titanium vertebral body replacement implants in the mid-thoracic spine using entire rib cage specimens
    Liebsch, Christian
    Aleinikov, Viktor
    Kerimbayev, Talgat
    Akshulakov, Serik
    Kocak, Tugrul
    Vogt, Morten
    Jansen, Jan Ulrich
    Wilke, Hans-Joachim
    CLINICAL BIOMECHANICS, 2020, 78 (78)
  • [27] Anterior corpectomy and reconstruction using dynamic cervical plate and titanium mesh cage for cervical spondylotic myelopathy A minimum 5-year follow-up study
    Zeng, Junfeng
    Duan, Yuchen
    Yang, Yi
    Wang, Beiyu
    Hong, Ying
    Lou, Jigang
    Ning, Ning
    Liu, Hao
    MEDICINE, 2018, 97 (05)
  • [28] Reconstruction of the Distal Humerus and Elbow Joint Using a Pedicled Scapular Flap: Case Report
    Nthumba, Peter
    George, Susan
    Jami, Michael
    Nyoro, Partick
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (06): : 1150 - 1154
  • [29] Titanium mesh cage fracture after lumbar reconstruction surgery: a case report and literature review
    Wang, Shan-Jin
    Liu, Xiao-Ming
    Zhao, Wei-Dong
    Wu, De-Sheng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (04): : 5559 - 5564
  • [30] Titanium mesh cage as an alternative reconstruction method for epiphyseal-sparing tumour resections in children
    Ayvaz, Mehmet
    Bekmez, Senol
    Yucekul, Altug
    Mermerkaya, Musa U.
    Tokgozoglu, A. Mazhar
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2018, 27 (04): : 350 - 355