Anterior thoracic spine reconstruction using a titanium mesh cage and pedicled rib flap

被引:10
|
作者
O'Shaughnessy, Brian A.
Ondra, Stephen L.
Ganju, Aruna
Said, Hakim K.
Few, Julius W.
Liu, John C.
机构
[1] Northwestern Univ, Dept Neurol Surg, Feinberg Sch Med, McGaw Med Ctr, Chicago, IL 60611 USA
[2] Northwestern Univ, Div Plast & Reconstruct Surg, Feinberg Sch Med, McGaw Med Ctr, Chicago, IL 60611 USA
关键词
osteomyelitis; spine metastases; thoracic spine; titanium mesh cage; vascularized graft;
D O I
10.1097/01.brs.0000226017.28265.a6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A retrospective clinical study. Objectives. To evaluate the safety and efficacy of using an integrated titanium mesh cage and pedicled rib flap for thoracic spine reconstruction in patients at high risk of pseudarthrosis. Summary of Background Data. A variety of materials are available for interbody thoracic reconstruction; however, the optimal treatment of patients at high risk of pseudarthrosis remains a challenging problem. Free or pedicled bone flaps have been shown to be highly effective in terms of promoting fusion and titanium mesh cages provide excellent structural support. Methods. Eleven patients who underwent anterior thoracic corpectomy and spinal reconstruction using an integrated titanium mesh cage and pedicled rib flap were analyzed with a mean follow-up of 37 months ( range, 25-55 months). The etiology of spinal disease was infection in 7 (64%) patients and tumor in the remaining 4 (36%) patients. Seven ( 64%) patients were treated with only an anterior approach while the remaining 4 ( 36%) patients underwent circumferential spinal reconstruction. Results. All patients demonstrated clinical and radiographic evidence of spinal fusion at the time of follow-up. All patients had stable or improved Frankel grades after surgery. There was a mean kyphosis correction of 7 for both the focal and regional thoracic kyphosis. There were three significant postoperative complications: bilateral pleural effusion, gram-negative bacteremia, and transient right lower extremity weakness requiring reoperation and pedicle screw revision. Two patients died after surgery: one from aneurysmal subarachnoid hemorrhage and the other from complications of breast cancer. Conclusions. The use of an integrated rib flap and titanium mesh cage construct appears to be a safe and effective means of providing immediate and substantial anterior column support as well as achieving arthrodesis in challenging fusion candidates.
引用
收藏
页码:1820 / 1827
页数:8
相关论文
共 50 条
  • [1] Kyphectomy with anterior column reconstruction using titanium mesh cage in meningomyelocele patients
    Hussien, Mohammed Ali
    Elbadrawi, Ahmed
    Zayan, Mohammed
    SICOT-J, 2022, 8
  • [2] Effects of the rib cage on thoracic spine flexibility
    Sham, ML
    Zander, T
    Rohmann, A
    Bergmann, G
    BIOMEDIZINISCHE TECHNIK, 2005, 50 (11): : 361 - 365
  • [3] Cage Displacement after anterior Decompression and Interbody Titanium Mesh Cage Placement in Caries Spine
    Ahmad, Rafique
    Ahmad, Ijaz
    Akram, Rizwan
    Zaman, Atiq Uz
    Aziz, Amer
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2016, 10 (03): : 730 - 733
  • [4] Stability provided by the sternum and rib cage in the thoracic spine
    Watkins, R
    Watkins, R
    Williams, L
    Ahlbrand, S
    Garcia, R
    Karamanian, A
    Sharp, L
    Vo, C
    Hedman, T
    SPINE, 2005, 30 (11) : 1283 - 1286
  • [6] Anterior Radical Debridement and Reconstruction Using Titanium Mesh Cage for the Surgical Treatment of Thoracic and Thoracolumbar Spinal Tuberculosis: Minimium Five-Year Follow-Up
    Wang, Bing
    Li, Guohua
    Liu, Weidong
    Cheng, Ivan
    TURKISH NEUROSURGERY, 2011, 21 (04) : 575 - 581
  • [7] Mechanical Contribution of the Rib Cage in the Human Cadaveric Thoracic Spine
    Mannen, Erin M.
    Anderson, John T.
    Arnold, Paul M.
    Friis, Elizabeth A.
    SPINE, 2015, 40 (13) : E760 - E766
  • [8] Preliminary surgical result of cervical spine reconstruction with a dynamic plate and titanium mesh cage
    Chung, Dae-Yeong
    Cho, Dae-Chul
    Lee, Sun-Ho
    Sung, Joo-Kyung
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2007, 41 (02) : 111 - 116
  • [9] Mechanical analysis of the human cadaveric thoracic spine with intact rib cage
    Mannen, Erin M.
    Anderson, John T.
    Arnold, Paul M.
    Friis, Elizabeth A.
    JOURNAL OF BIOMECHANICS, 2015, 48 (10) : 2060 - 2066
  • [10] Influence of Sequential Ponte Osteotomies on the Human Thoracic Spine With a Rib Cage
    Mannen E.M.
    Arnold P.M.
    Anderson J.T.
    Friis E.A.
    Spine Deformity, 2017, 5 (2) : 91 - 96