Thermal Performance of a Closed-Loop Pulsating Heat Pipe With Multiple Heat Sources

被引:15
作者
Kammuang-Lue, Niti [1 ]
Sakulchangsatjatai, Phrut [1 ]
Terdtoon, Pradit [1 ]
机构
[1] Chiang Mai Univ, Dept Mech Engn, Fac Engn, Chiang Mai 50200, Thailand
关键词
FLOW; PART; 2-PHASE; FLUIDS; FLUX;
D O I
10.1080/01457632.2013.870000
中图分类号
O414.1 [热力学];
学科分类号
摘要
A closed-loop pulsating heat pipe with multiple heat sources (CLPHP w/MHS) was invented to be used as a heat transfer medium between a number of heat sources to a single heat sink. However, an issue on the suitable heat source arrangement that causes the heat pipe to have the highest thermal performance was suspicious. The CLPHP w/MHS was made of a copper capillary tube with 32 turns. There were three heat sources with nonidentical input heat flux installed along a longitudinal axis in the evaporator section. Experimental investigations were conducted by permuting the heat sources into six unduplicated arrangements. For the vertical CLPHPs, the highest thermal performance is achieved when heat sources are arranged in consecutive order ascending from the lowest heat flux at the inlet of the evaporator section, since working fluid is promoted to circulate in complete one direction and then the heat can transfer more continuously. Finally, for the horizontal CLPHPs, the highest thermal performance is achieved when the heat sources are arranged in opposite order to the case of vertical CLPHPs, that is, descending from the highest heat flux, since working fluid pulsates with no intermission stop and this causes the heat transfer to be not interrupted.
引用
收藏
页码:1161 / 1172
页数:12
相关论文
共 29 条
[1]  
Akachi H., 1996, PROC 5 INT HEAT PIPE, P208
[2]   Closed loop pulsating heat pipes - Part A: parametric experimental investigations [J].
Charoensawan, P ;
Khandekar, S ;
Groll, M ;
Terdtoon, P .
APPLIED THERMAL ENGINEERING, 2003, 23 (16) :2009-2020
[3]   Thermal performance of horizontal closed-loop oscillating heat pipes [J].
Charoensawan, Piyanun ;
Terdtoon, Pradit .
APPLIED THERMAL ENGINEERING, 2008, 28 (5-6) :460-466
[4]   Effect of pressure on critical heat flux in uniformly heated vertical annulus under low flow conditions [J].
Chun, SY ;
Chung, HJ ;
Moon, SK ;
Yang, SK ;
Chung, MK ;
Schoesse, T ;
Aritomi, M .
NUCLEAR ENGINEERING AND DESIGN, 2001, 203 (2-3) :159-174
[5]   Experimental investigations of a closed-loop oscillating heat pipe [J].
Dmitrin, V. I. ;
Maidanik, Yu. F. .
HIGH TEMPERATURE, 2007, 45 (05) :703-707
[6]  
Dobson R. T., 2003, P 7 INT HEAT PIP S J, P325
[7]   Relation between temperature fluctuation of a heating surface and generation of drypatch caused by a cylindrical spacer in a vertical boiling two-phase upward flow in a narrow annular channel [J].
Fukano, T ;
Mori, S ;
Akamatsu, S ;
Baba, A .
NUCLEAR ENGINEERING AND DESIGN, 2002, 217 (1-2) :81-90
[8]   Experimental investigation of cryogenic oscillating heat pipes [J].
Jiao, A. J. ;
Ma, H. B. ;
Critser, J. K. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (15-16) :3504-3509
[9]  
Kammuang-lue N., 2011, P 3 INT C SCI TECHN, P1
[10]  
Kammuang-lue N., 2010, ENERGY RES J, V1, P96