A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses

被引:49
作者
Nejima, R
Miyata, K
Honbou, M
Tokunaga, T
Tanabe, T
Sato, M
Oshika, T
机构
[1] Univ Tsukuba, Inst Clin Med, Dept Ophthalmol, Tsukuba, Ibaraki 3058575, Japan
[2] Miyata Eye Hosp, Miyazaki, Japan
关键词
D O I
10.1136/bjo.2003.037663
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims: To compare the postoperative performance of single and three piece acrylic foldable intraocular lenses (IOLs). Methods: 20 patients underwent bilateral cataract surgery with a single piece SA30AL IOL in one eye and a three piece MA30BA IOL in the other eye. The eyes were randomly assigned to either a single or three piece lens. The amount of IOL decentration and tilt, area of anterior capsule opening, and degree of posterior capsule opacification were measured using the Scheimpflug anterior segment analysis system (Nidek EAS-1000). Visual acuity and contrast sensitivity were examined. Measurements were performed by masked examiners before and 1 day, 1 week, 1, 3, 6, and 18 months after surgery. Results: There were no significant differences between the two groups (p>0.05, paired t test) in the amount of IOL decentration, IOL tilt, area of anterior capsule opening, degree of posterior capsule opacification, best corrected visual acuity, and contrast sensitivity throughout the 18 month follow up period. Conclusion: The single and three piece acrylic foldable IOLs are equally stable in the eye after surgery.
引用
收藏
页码:746 / 749
页数:4
相关论文
共 35 条
  • [31] SUGITA S, IN PRESS AM J OPHTHA
  • [32] Posterior capsule opacification with AcrySof and poly(methyl methacrylate) intraocular lenses -: Comparative study with a 3-year follow-up
    Sundelin, K
    Friberg-Riad, Y
    Östberg, A
    Sjöstrand, J
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (10) : 1586 - 1590
  • [33] Effect of tranilast eyedrops in preventing posterior capsule opacification: Preliminary report
    Tobari, I
    Iwaki, Y
    Miyake, K
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (10) : 1394 - 1399
  • [34] Evaluation of 3 modern single-piece foldable intraocular lenses - Clinicopathological study of posterior capsule opacification in a rabbit model
    Vargas, LG
    Peng, Q
    Apple, DJ
    Escobar-Gomez, M
    Pandey, SK
    Arthur, SN
    Hoddinott, DSM
    Schmidbauer, JM
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (07) : 1241 - 1250
  • [35] Versura P, 1999, J CATARACT REFR SURG, V25, P527