Quantifying Myocardial Contractility Changes Using Ultrasound-Based Shear Wave Elastography

被引:24
作者
Vejdani-Jahromi, Maryam [1 ]
Freedman, Jenna [1 ]
Nagle, Matthew [1 ]
Kim, Young-Joong [1 ]
Trahey, Gregg E. [1 ]
Wolf, Patrick D. [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, 1427 FCIEMAS,101 Sci Dr,Box 90281, Durham, NC 27708 USA
基金
美国国家卫生研究院;
关键词
Contractility; Shear wave elasticity imaging (SWEI); Elastography; Gregg effect; Tissue characterization; Ultrasound imaging; FORCE; STIFFNESS;
D O I
10.1016/j.echo.2016.10.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Myocardial contractility, a significant determinant of cardiac function, is valuable for diagnosis and evaluation of treatment in cardiovascular disorders including heart failure. Shear wave elasticity imaging (SWEI) is a newly developed ultrasound-based elastographic technique that can directly assess the stiffness of cardiac tissue. The aim of this study was to verify the ability of this technique to quantify contractility changes in the myocardium. Methods: In 12 isolated rabbit hearts, SWEI measurements were made of systolic stiffness at five different coronary perfusion pressures from 0 to 92 mm Hg. The changes in coronary perfusion were used to induce acute stepwise reversible changes in cardiac contractility via the Gregg effect. The Gregg effect is the dependency of contractility on coronary perfusion. In four of the hearts, the measurements were repeated after delivery of gadolinium, which is known to block the Gregg effect. Results: Systolic stiffness measured by SWEI changed linearly with coronary perfusion pressure, with a slope of 0.27 kPa/mm Hg (mean of 95% CI, R-2 = 0.73). As expected, the change in contractility due to the Gregg effect was blocked by gadolinium, with a significant reduction of the slope to 0.08 kPa/mm Hg. Conclusions: SWEI measurements of systolic stiffness provide an index of contractility in the unloaded isolated rabbit heart. Although this study was done under ideal imaging conditions and with nonphysiologic loading conditions, it reinforces the concept that this ultrasound technique has the potential to provide a direct and noninvasive index of cardiac contractility.
引用
收藏
页码:90 / 96
页数:7
相关论文
共 29 条
[11]   INTRACARDIAC ECHOCARDIOGRAPHY MEASUREMENT OF DYNAMIC MYOCARDIAL STIFFNESS WITH SHEAR WAVE VELOCIMETRY [J].
Hollender, Peter J. ;
Wolf, Patrick D. ;
Goswami, Robi ;
Trahey, Gregg E. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (07) :1271-1283
[12]   In Vivo assessment of myocardial stiffness with acoustic radiation force impulse imaging [J].
Hsu, Stephen J. ;
Bouchard, Richard R. ;
Dumont, Douglas M. ;
Wolf, Patrick D. ;
Trahey, Gregg E. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (11) :1706-1719
[13]   Mechanically activated currents in chick heart cells [J].
Hu, H ;
Sachs, F .
JOURNAL OF MEMBRANE BIOLOGY, 1996, 154 (03) :205-216
[14]   CORONARY PERFUSION RELATED CHANGES IN MYOCARDIAL CONTRACTILE-FORCE AND SYSTOLIC VENTRICULAR STIFFNESS [J].
IWAMOTO, T ;
BAI, XJ ;
DOWNEY, HF .
CARDIOVASCULAR RESEARCH, 1994, 28 (09) :1331-1336
[15]   Tissue Doppler Imaging in Echocardiography: Value and Limitations [J].
Kadappu, Krishna K. ;
Thomas, Liza .
HEART LUNG AND CIRCULATION, 2015, 24 (03) :224-233
[16]   Magnetic resonance elastography as a method to estimate myocardial contractility [J].
Kolipaka, Arunark ;
Aggarwal, Shivani R. ;
Mcgee, Kiaran P. ;
Anavekar, Nandan ;
Manduca, Armando ;
Ehman, Richard L. ;
Araoz, Philip A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (01) :120-127
[17]   Increased coronary perfusion augments cardiac contractility in the rat through stretch-activated ion channels [J].
Lamberts, RR ;
Van Rijen, MHP ;
Sipkema, P ;
Fransen, P ;
Sys, SU ;
Westerhof, N .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2002, 282 (04) :H1334-H1340
[18]   ACCOUNTING FOR THE GREGG EFFECT IN TETANISED CORONARY ARTERIAL PRESSURE-FLOW RELATIONSHIPS [J].
LIVINGSTON, JZ ;
HALPERIN, HR ;
YIN, FCP .
CARDIOVASCULAR RESEARCH, 1994, 28 (02) :228-234
[19]   AN AXIAL VELOCITY ESTIMATOR FOR ULTRASOUND BLOOD-FLOW IMAGING, BASED ON A FULL EVALUATION OF THE DOPPLER EQUATION BY MEANS OF A 2-DIMENSIONAL AUTOCORRELATION APPROACH [J].
LOUPAS, T ;
POWERS, JT ;
GILL, RW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (04) :672-688
[20]  
Maruyama Y, 1996, CARDIAC VASCULAR REM, P321