Optimising the design of Gas Microstrip Detectors for soft x-ray detection

被引:0
|
作者
Mir, JA [1 ]
Bateman, JE [1 ]
Barlow, R [1 ]
Derbyshire, GE [1 ]
Stephenson, R [1 ]
机构
[1] CLRC, Rutherford Appleton Lab, Didcot, Oxon, England
关键词
D O I
10.1109/NSSMIC.2001.1009712
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This report describes development work in which systematic changes in the electrode pattern of a Gas Microstrip Detector are explored in the search for higher avalanche gains and enhanced stability. It is found that the width of the cathode structure is the main determinant of the detector stability. With the correct cathode width, gas gains of >50 000 are comfortably attainable with low detector noise so that x-rays can potentially be detected down to the limit of a single x-ray-produced photoelectron.
引用
收藏
页码:951 / 955
页数:5
相关论文
共 50 条
  • [1] Optimizing the design of gas microstrip detectors for soft X-ray detection
    Bateman, JE
    Barlow, R
    Derbyshire, GE
    Mir, JA
    Stephenson, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 894 - 898
  • [2] High-gain microstrip gas counters for soft X-ray detection
    Bateman, JE
    Barlow, R
    Derbyshire, GE
    Mir, JA
    Stephenson, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (1-2): : 273 - 276
  • [3] Digital x-ray imaging using gas microstrip detectors
    Dixit, MS
    Armitage, JC
    Bouius, D
    Diaconescu, L
    Dubeau, J
    Grabari, M
    Johns, PC
    Karlen, D
    Oakham, FG
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1597 - 1601
  • [4] Gas microstrip detectors for X-ray tomographic flow imaging
    Key, MJ
    Morton, EJ
    Luggar, RD
    Kundu, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 496 (2-3): : 504 - 508
  • [5] A gas puff filter for soft X-ray detectors
    Sorokin, SA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1999, 42 (03) : 413 - 415
  • [6] Active Detectors for Plasma Soft X-Ray Detection at PALS
    Granja, C.
    Linhart, V.
    Platkevic, M.
    Jakubek, J.
    Krousky, E.
    Pospisil, S.
    Renner, O.
    Slavicek, T.
    ACTA POLYTECHNICA, 2010, 50 (02) : 12 - 21
  • [7] Studies of the gain properties of gas microstrip detectors relevant to their application as X-ray and electron detectors
    Mir, JA
    Bateman, JE
    Connolly, JF
    Derbyshire, GE
    Duxbury, DM
    Lipp, J
    Simmons, JE
    Spill, EJ
    Stephenson, R
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 306 - 310
  • [8] A gas microstrip X-ray detector for soft energy fluorescence EXAFS
    Smith, AD
    Bateman, JE
    Derbyshire, GE
    Duxbury, DM
    Lipp, J
    Spill, EJ
    Stephenson, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 1136 - 1139
  • [9] Electron-yield x-ray absorption spectroscopy with gas microstrip detectors
    Rayment, T
    Schroeder, SLM
    Moggridge, GD
    Bateman, JE
    Derbyshire, GE
    Stephenson, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (10): : 3640 - 3645
  • [10] Development of gas microstrip detectors for digital X-ray imaging and radiation dosimetry
    Dixit, MS
    Armitage, JC
    Dubeau, J
    Gobbi, DG
    Johns, PC
    Karlen, D
    Oakham, FG
    Waker, AJ
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (03) : 809 - 813