Measurement of the Aortic Annulus Area and Diameter by Three-Dimensional Transesophageal Echocardiography in Transcatheter Aortic Valve Replacement

被引:3
作者
Ebuchi, Keigo [1 ]
Yoshitani, Kenji [1 ]
Kanemaru, Eiki [1 ]
Fujii, Tasuku [1 ]
Tsukinaga, Akito [1 ]
Shimahara, Yusuke [2 ]
Ohnishi, Yoshiniko [1 ]
机构
[1] Natl Cerebral & Cardiovasc Ctr, Dept Anesthesiol, 5-7-1 Fujishirodai, Suita, Osaka 5658565, Japan
[2] Natl Cerebral & Cardiovasc Ctr, Dept Cardiovasc Surg, Osaka, Japan
关键词
trans-catheter aortic valve replacement; multi-detector computed tomography; three-dimensional echocardiography; aortic stenosis; DIMENSIONS; IMPLANTATION; ANGIOGRAPHY; ACCURACY; CT;
D O I
10.1053/j.jvca.2019.04.025
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objectives: Sizing of the aortic valve is crucial for transcatheter aortic valve replacement (TAVR). Multidetector computed tomography (MDCT) is used for sizing. Recently, three-dimensional transesophageal echocardiography (3DTEE) has enabled accurate measurement of the aortic annulus area and diameter in cases that are difficult to measure. The authors compared measurements of aortic annulus areas and diameters acquired by MDCT and 3DTEE. Design: Retrospective observational study. Setting: Single national center. Participants: Sixty-eight patients who underwent TAVR replacement between September 2015 and March 2017. Interventions: None. Measurements and Main Results: The authors extracted and compared preoperative measurements of the aortic annulus area, as well as the long and short-axis diameter, measured by MDCT and 3DTEE. There was no significant difference in the aortic annulus area (409 +/- 74 v 414 +/- 70 mm(2), p = 0.15) or short-axis diameter (20.4 +/- 2.0 v 20.6 +/- 1.9 mm, p = 0.103) between 3DTEE and MDCT, but the long-axis diameter differed significantly (25.0 +/- 2.4 v 25.8 +/- 2.0 mm, p < 0.001), respectively. Prosthesis sizes based on 3DTEE and MDCT were the same, except in 3 patients who could not stay still during MDCT measurement; in those cases, prosthesis sizes based on 3DTEE were adopted. Conclusions: Measurements of the aortic annulus area and diameter in TAVR were similar between 3DTEE and MDCT. Patients who have difficulty remaining still during MDCT measurement because of dementia should have their prostheses sized based on 3DTEE measurements. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:2387 / 2393
页数:7
相关论文
共 20 条
[1]   Systematic review of systematic reviews of non-pharmacological interventions to treat behavioural disturbances in older patients with dementia. The SENATOR-OnTop series [J].
Abraha, Iosief ;
Rimland, Joseph M. ;
Trotta, Fabiana Mirella ;
Dell'Aquila, Giuseppina ;
Cruz-Jentoft, Alfonso ;
Petrovic, Mirko ;
Gudmundsson, Adalsteinn ;
Soiza, Roy ;
O'Mahony, Denis ;
Guaita, Antonio ;
Cherubini, Antonio .
BMJ OPEN, 2017, 7 (03)
[2]   A Practical Guide to Multimodality Imaging of Transcatheter Aortic Valve Replacement [J].
Bloomfield, Gerald S. ;
Gillam, Linda D. ;
Hahn, Rebecca T. ;
Kapadia, Samir ;
Leipsic, Jonathon ;
Lerakis, Stamatios ;
Tuzcu, Murat ;
Douglas, Pamela S. .
JACC-CARDIOVASCULAR IMAGING, 2012, 5 (04) :441-455
[3]   Preoperative Assessment of Aortic Annulus Dimensions: Comparison of Noninvasive and Intraoperative Measurement [J].
Dashkevich, Alexey ;
Blanke, Philipp ;
Siepe, Matthias ;
Pache, Gregor ;
Langer, Mathias ;
Schlensak, Christian ;
Beyersdorf, Friedhelm .
ANNALS OF THORACIC SURGERY, 2011, 91 (03) :709-715
[4]   Intraoperative 2D and 3D transoesophageal echocardiographic predictors of aortic regurgitation after transcatheter aortic valve implantation [J].
Gripari, Paola ;
Ewe, See Hooi ;
Fusini, Laura ;
Muratori, Manuela ;
Ng, Arnold C. T. ;
Cefalu, Claudia ;
Delgado, Victoria ;
Schalij, Martin J. ;
Bax, Jeroen J. ;
Marsan, Nina Ajmone ;
Tamborini, Gloria ;
Pepi, Mauro .
HEART, 2012, 98 (16) :1229-1236
[5]   Automated and Manual Measurements of the Aortic Annulus with ECG-Gated Cardiac CT Angiography Prior to Transcatheter Aortic Valve Replacement: Comparison with 3D-Transesophageal Echocardiography [J].
Guez, David ;
Boroumand, Gilda ;
Ruggiero, Nicholas J. ;
Mehrotra, Praveen ;
Halpern, Ethan Joseph .
ACADEMIC RADIOLOGY, 2017, 24 (05) :587-593
[6]   Is intra-procedure three-dimensional transesophageal echocardiogram an alternative to preprocedure multidetector computed tomography for the measurement of the aortic annulus in patients undergoing transcatheter aortic valve replacement? [J].
Hafiz, Abdul Moiz ;
Medranda, Giorgio A. ;
Kakouros, Nikolaos ;
Patel, Jay ;
Kahan, Jonathan ;
Gubernikoff, George ;
Ray, Beevash ;
Paruchuri, Vijayapraveena ;
DeLeon, Joshua ;
Marzo, Kevin ;
Calixte, Rose ;
Gaztanaga, Juan .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (08) :1195-1202
[7]   Prosthesis sizing for transcatheter aortic valve implantation - Comparison of three dimensional transesophageal echocardiography with multislice computed tomography [J].
Husser, Oliver ;
Holzamer, Andreas ;
Resch, Markus ;
Endemann, Dierk H. ;
Nunez, Julio ;
Bodi, Vicente ;
Schmid, Christof ;
Riegger, Guenter A. J. ;
Goessmann, Holger ;
Hamer, Okka ;
Stroszczynski, Christian ;
Luchner, Andreas ;
Hilker, Michael ;
Hengstenberg, Christian .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (04) :3431-3438
[8]   Cross-Sectional Computed Tomographic Assessment Improves Accuracy of Aortic Annular Sizing for Transcatheter Aortic Valve Replacement and Reduces the Incidence of Paravalvular Aortic Regurgitation [J].
Jilaihawi, Hasan ;
Kashif, Mohammad ;
Fontana, Gregory ;
Furugen, Azusa ;
Shiota, Takahiro ;
Friede, Gerald ;
Makhija, Rakhee ;
Doctor, Niraj ;
Leon, Martin B. ;
Makkar, Raj R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (14) :1275-1286
[9]   Standardized Imaging for Aortic Annular Sizing Implications for Transcatheter Valve Selection [J].
Kasel, Albert M. ;
Cassese, Salvatore ;
Bleiziffer, Sabine ;
Amaki, Makoto ;
Hahn, Rebecca T. ;
Kastrati, Adnan ;
Sengupta, Partho P. .
JACC-CARDIOVASCULAR IMAGING, 2013, 6 (02) :249-262
[10]   Impact of Methodologic Differences in Three-Dimensional Echocardiographic Measurements of the Aortic Annulus Compared with Computed Tomographic Angiography Before Transcatheter Aortic Valve Replacement [J].
Khalique, Omar K. ;
Hamid, Nadira B. ;
White, Jonathon M. ;
Bae, David J. ;
Kodali, Susheel K. ;
Nazif, Tamim M. ;
Vahl, Torsten P. ;
Paradis, Jean-Michel ;
George, Isaac ;
Leon, Martin B. ;
Hahn, Rebecca T. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (04) :414-421