Energy performance of Double-Skin Facades in temperate climates: A systematic review and meta-analysis

被引:115
作者
Pomponi, Francesco [1 ]
Piroozfar, Poorang A. E. [2 ]
Southall, Ryan [3 ]
Ashton, Philip [2 ]
Farr, Eric. R. P. [4 ]
机构
[1] Univ Cambridge, Dept Engn, Cambridge CB2 1PZ, Cambs, England
[2] Univ Brighton, Sch Environm & Technol, Brighton BN2 4GJ, E Sussex, England
[3] Univ Brighton, Sch Architecture, Brighton BN2 4AT, E Sussex, England
[4] NewSch Architecture Design, San Diego, CA 92101 USA
关键词
Cooling loads; Double Skin Facade; Embodied energy; Heating loads; Natural ventilation; Operational energy; LIFE-CYCLE ASSESSMENT; NATURAL VENTILATION; OFFICE BUILDINGS; PERSPECTIVES; ENVELOPE; SECTOR;
D O I
10.1016/j.rser.2015.10.075
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Double Sldn Facades (DSFs) are applied in both new and existing buildings, especially in temperate climates. Research in this area is steadily growing; however, there is a lack of conclusive results in available literature about energy performances related to the DSF, thus limiting a better and more informed application of this technology in the Architecture Engineering and Construction (AEC) sector. This article systematically reviews more than 50 articles which have dealt with the energy related performance of DSFs in temperate climates and provide a meta-analysis of the numerical findings published in the studies examined. Energy related figures are presented separately for embodied and operational energy. Specifically, the operational energy end-uses taken into account are heating, cooling, lighting, and ventilation. Numerical results in the literature are normalised and expressed in form of percentage of maximum energy reduction/increment compared to a base case (e.g. a single skin case) used as a reference in the corresponding studies. Such an approach is meant to provide a reliable comparison of published figures. Key facade parameters (DSF spatial configurations, cavity width and ventilation), building parameters (orientation and climatic areas) and the methodological approaches used in the reviewed studies were adopted as clustering criteria. Several clustering criteria present extremely spread values, indicating the necessity to further investigate, understand, and attempt to reduce such high discrepancies in operational energy performances. Additionally, and more importantly, almost no information exists on DSFs life cycle energy figures, highlighting an important gap that requires further research. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1525 / 1536
页数:12
相关论文
共 91 条
[1]  
Andjelkovic AS, 2012, THERM SCI, P16
[2]  
[Anonymous], 2013, INT J SUST BUILD TEC, DOI DOI 10.1080/2093761X.2012.759890
[3]  
Arons D., 2000, Properties and Applications of Double-Skin Building Facades
[4]   Life cycle assessment of electricity production from renewable energies: Review and results harmonization [J].
Asdrubali, Francesco ;
Baldinelli, Giorgio ;
D'Alessandro, Francesco ;
Scrucca, Flavio .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 42 :1113-1122
[5]  
Baldinelli G, 2009, BUILD ENVIRON, P44
[6]  
Ballestini G, 2005, BUILD ENVIRON, P40
[7]   A simple model to study ventilated facades energy performance [J].
Balocco, C .
ENERGY AND BUILDINGS, 2002, 34 (05) :469-475
[8]   Perspectives of double skin facades for naturally ventilated buildings: A review [J].
Barbosa, Sabrina ;
Ip, Kenneth .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 40 :1019-1029
[9]  
Belgian Building Research Institute (BBRI), 2002, SOURC BOOK BETT UND
[10]  
Blumenberg J., 2006, INT C REC ADV HEAT T