Focusing light inside dynamic scattering media with millisecond digital optical phase conjugation

被引:150
作者
Liu, Yan [1 ]
Ma, Cheng [1 ]
Shen, Yuecheng [1 ]
Shi, Junhui [1 ]
Wang, Lihong V. [1 ]
机构
[1] Washington Univ, Opt Imaging Lab, Dept Biomed Engn, One Brookings Dr, St Louis, MO 63130 USA
基金
美国国家卫生研究院;
关键词
REVERSED ADAPTED-PERTURBATION; ENCODED LIGHT; TURBIDITY SUPPRESSION; TRANSMISSION MATRIX; TIME-REVERSAL; TISSUE; DEEP; MODULATION; MICROSCOPY; FLOWMETRY;
D O I
10.1364/OPTICA.4.000280
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Wavefront shaping based on digital optical phase conjugation (DOPC) focuses light through or inside scattering media, but the low speed of DOPC prevents it from being applied to thick, living biological tissue. Although a fast DOPC approach was recently developed, the reported single-shot wavefront measurement method does not work when the goal is to focus light inside, instead of through, highly scattering media. Here, using a ferroelectric liquid crystal based spatial light modulator, we develop a simpler but faster DOPC system that focuses light not only through, but also inside scattering media. By controlling 2.6 x 10(5) optical degrees of freedom, our system focused light through 3 mm thick moving chicken tissue, with a system latency of 3.0 ms. Using ultrasound-guided DOPC, along with a binary wavefront measurement method, our system focused light inside a scattering medium comprising moving tissue with a latency of 6.0 ms, which is one to two orders of magnitude shorter than those of previous digital wavefront shaping systems. Since the demonstrated speed approaches tissue decorrelation rates, this work is an important step toward in vivo deep-tissue non-invasive optical imaging, manipulation, and therapy. (C) 2017 Optical Society of America
引用
收藏
页码:280 / 288
页数:9
相关论文
共 60 条
[31]   Single-exposure optical focusing inside scattering media using binarized time-reversed adapted perturbation [J].
Ma, Cheng ;
Zhou, Fengbo ;
Liu, Yan ;
Wang, Lihong V. .
OPTICA, 2015, 2 (10) :869-876
[32]  
Ma C, 2014, NAT PHOTONICS, V8, P931, DOI [10.1038/nphoton.2014.251, 10.1038/NPHOTON.2014.251]
[33]  
Mosk AP, 2012, NAT PHOTONICS, V6, P283, DOI [10.1038/NPHOTON.2012.88, 10.1038/nphoton.2012.88]
[34]  
Ntziachristos V, 2010, NAT METHODS, V7, P603, DOI [10.1038/NMETH.1483, 10.1038/nmeth.1483]
[35]   Focusing and scanning light through a multimode optical fiber using digital phase conjugation [J].
Papadopoulos, Ioannis N. ;
Farahi, Salma ;
Moser, Christophe ;
Psaltis, Demetri .
OPTICS EXPRESS, 2012, 20 (10) :10583-10590
[36]   Measuring the Transmission Matrix in Optics: An Approach to the Study and Control of Light Propagation in Disordered Media [J].
Popoff, S. M. ;
Lerosey, G. ;
Carminati, R. ;
Fink, M. ;
Boccara, A. C. ;
Gigan, S. .
PHYSICAL REVIEW LETTERS, 2010, 104 (10)
[37]   Optical focusing inside scattering media with time-reversed ultrasound microbubble encoded light [J].
Ruan, Haowen ;
Jang, Mooseok ;
Yang, Changhuei .
NATURE COMMUNICATIONS, 2015, 6
[38]   Iterative Time-Reversed Ultrasonically Encoded Light Focusing in Backscattering Mode [J].
Ruan, Haowen ;
Jang, Mooseok ;
Judkewitz, Benjamin ;
Yang, Changhuei .
SCIENTIFIC REPORTS, 2014, 4
[39]   Sub-Nyquist sampling boosts targeted light transport through opaque scattering media [J].
Shen, Yuecheng ;
Liu, Yan ;
Ma, Cheng ;
Wang, Lihong V. .
OPTICA, 2017, 4 (01) :97-102
[40]   Focusing light through biological tissue and tissue-mimicking phantoms up to 9.6 cm in thickness with digital optical phase conjugation [J].
Shen, Yuecheng ;
Liu, Yan ;
Ma, Cheng ;
Wang, Lihong V. .
JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (08)