Reconstruction of X-Ray Fluorescence Computed Tomography From Sparse-View Projections via L1-Norm Regularized EM Algorithm

被引:7
作者
Shi, Junwei [1 ]
Hara, Daiki [1 ]
Tao, Wensi [1 ]
Dogan, Nesrin [1 ]
Pollack, Alan [1 ]
Ford, John Chetley [1 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Radiat Oncol, Miami, FL 33136 USA
来源
IEEE ACCESS | 2020年 / 8卷
关键词
Imaging; X-ray imaging; Detectors; Photonics; Image reconstruction; Computed tomography; Tomography; X-ray fluorescence computed tomography; image reconstruction; sparse projection view; gold nanoparticles; NANOPARTICLE-LOADED OBJECTS; GOLD NANOPARTICLES; L-CURVE; FEASIBILITY;
D O I
10.1109/ACCESS.2020.3039927
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
X-ray fluorescence computed tomography (XFCT) as a molecular imaging modality can simultaneously identify the localization and quantify the concentration of high-atomic-number contrast agents such as gold nanoparticles (GNPs). Commonly used benchtop pencil-beam XFCT, consisting of a polychromatic x-ray source and a single-pixel spectrometer, suffers from long scanning time and high imaging dose. Sparse-view strategy benefits XFCT to reduce both scanning time and imaging dose. Nevertheless, its reconstruction undergoes ill-posedness induced by the compressive sampling. To preserve consistent imaging quality for sparse-view XFCT, we proposed an iterative Bayesian algorithm based on L1-norm constraint, wherein the L1-norm regularization is included in the one-step-late expectation maximization (OSL-EM) algorithm with regularization parameter determined based on L-curve criteria. The proposed algorithm was verified by imaging a 3-cm-diameter water phantom with 4 inserts containing GNP solutions with concentrations of 0.02, 0.04, 0.08, and 0.16 wt.%, on an in-house-developed dual-modality transmission CT and XFCT system. Different numbers (i.e. 36, 18, 9, and 6) of projection views were used for XFCT reconstruction, to evaluate the performance of various reconstruction algorithms. L1-regularized EM algorithm demonstrated the consistent robustness to suppress background artifacts and localize low-concentration GNPs (0.02 wt.%) with submillimeter accuracy, when the number of projection views reduces from 36 to 9. Moreover, our method's potential for small tumor spare-view XFCT imaging was validated on a mouse surgically implanted with a 6-mm GNP target.
引用
收藏
页码:211576 / 211584
页数:9
相关论文
共 37 条
[1]   Optimized Detector Angular Configuration Increases the Sensitivity of X-ray Fluorescence Computed Tomography (XFCT) [J].
Ahmad, Moiz ;
Bazalova-Carter, Magdalena ;
Fahrig, Rebecca ;
Xing, Lei .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (05) :1140-1147
[2]   Cancer active targeting by nanoparticles: a comprehensive review of literature [J].
Bazak, Remon ;
Houri, Mohamad ;
El Achy, Samar ;
Kamel, Serag ;
Refaat, Tamer .
JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2015, 141 (05) :769-784
[3]   Experimental validation of L-shell x-ray fluorescence computed tomography imaging: phantom study [J].
Bazalova-Carter, Magdalena ;
Ahmad, Moiz ;
Xing, Lei ;
Fahrig, Rebecca .
JOURNAL OF MEDICAL IMAGING, 2015, 2 (04)
[4]   FLUORESCENCE TOMOGRAPHY USING SYNCHROTRON RADIATION AT THE NSLS [J].
BOISSEAU, P ;
GRODZINS, L .
HYPERFINE INTERACTIONS, 1987, 33 (1-4) :283-292
[5]   A NEW TOMOGRAPHIC DEVICE BASED ON THE DETECTION OF FLUORESCENT X-RAYS [J].
CESAREO, R ;
MASCARENHAS, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 277 (2-3) :669-672
[6]   X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp x-rays [J].
Cheong, Seong-Kyun ;
Jones, Bernard L. ;
Siddiqi, Arsalan K. ;
Liu, Fang ;
Manohar, Nivedh ;
Cho, Sang Hyun .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (03) :647-662
[7]   A detector's eye view (DEV)-based OSEM algorithm for benchtop x-ray fluorescence computed tomography (XFCT) image reconstruction [J].
Deng, Luzhen ;
Ahmed, Md F. ;
Jayarathna, Sandun ;
Feng, Peng ;
Wei, Biao ;
Cho, Sang Hyun .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (08)
[8]   Optimization of a table-top x-ray fluorescence computed tomography (XFCT) system [J].
Dunning, C. A. S. ;
Bazalova-Carter, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (23)
[9]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[10]   Limited view cone-beam x-ray luminescence tomography based on depth compensation and group sparsity prior [J].
Gao, Peng ;
Rong, Junyan ;
Liu, Tianshuai ;
Zhang, Wenli ;
Lan, Bin ;
Ouyang, Xiaoping ;
Lu, Hongbing .
JOURNAL OF BIOMEDICAL OPTICS, 2020, 25 (01)