Test-retest reliability of trunk accelerometric gait analysis

被引:191
|
作者
Henriksen, M
Lund, H
Moe-Nilssen, R
Bliddal, H
Danneskiod-Samsoe, B
机构
[1] Frederiksberg Univ Hosp, Parker Inst, DK-2000 Frederiksberg, Denmark
[2] Univ Bergen, Natl Inst Publ Hlth & Primary Hlth Care, Balance & Gait Unit, N-5009 Bergen, Norway
关键词
gait analysis; accelerometry; reliability; human locomotion; motor control;
D O I
10.1016/S0966-6362(03)00069-9
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The purpose of this study was to determine the test-retest reliability of a trunk accelerometric gait analysis in healthy subjects. Accelerations were measured during walking using a triaxial accelerometer mounted on the lumbar spine of the subjects. Six men and 14 women (mean age 35.2; range 18-57) underwent the same protocol on 2 consecutive days. The raw acceleration signals from six self-selected walking speeds were transformed into a horizontal-vertical coordinate system to remove unwanted variability caused by gravity. Acceleration root mean square values, cadences, step and stride lengths were then computed and interpolated using quadratic curve fits and point estimates were calculated at a standardised walking speed of 1.35 m/s. Relative reliability was determined using two models of intraclass correlation coefficients (ICC(1,1) and ICC(3,1)) to assess any systematic shifts and absolute reliability was determined using measurement error (ME). The results of the study showed high ICC values (0.77-0.96) and ME values of 0.007-0.01g for mean acceleration; 0.009 m for step lengths; 0.022 m for stride length and 1.644 step/min for cadences. In conclusion, the method was found to be reliable and may have a definite potential in clinical gait analysis. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:288 / 297
页数:10
相关论文
共 50 条
  • [1] Test-Retest Reliability of PODOSmart(R) Gait Analysis Insoles
    Loukovitis, Andreas
    Ziagkas, Efthymios
    Zekakos, Dimitrios Xypolias
    Petrelis, Alexandros
    Grouios, George
    SENSORS, 2021, 21 (22)
  • [2] Test-Retest Reliability of an Automated Infrared-Assisted Trunk Accelerometer-Based Gait Analysis System
    Hsu, Chia-Yu
    Tsai, Yuh-Show
    Yau, Cheng-Shiang
    Shie, Hung-Hai
    Wu, Chu-Ming
    SENSORS, 2016, 16 (08)
  • [3] Test-retest reliability of 3-dimensional computerized gait analysis
    Westhoff, B
    Hirsch, MA
    Hefter, H
    Wild, A
    Krauspe, R
    SPORTVERLETZUNG-SPORTSCHADEN, 2004, 18 (02) : 76 - 79
  • [4] Test-retest reliability of trunk accelerometry during standing and walking
    Moe-Nilssen, R
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1998, 79 (11): : 1377 - 1385
  • [5] Cluster analysis for test-retest Reliability
    Roy, Debdulal Dutta
    INTERNATIONAL JOURNAL OF PSYCHOLOGICAL RESEARCH, 2010, 3 (01): : 131 - 139
  • [6] Test-Retest Reliability of the MotionMetrix Software for the Analysis of Walking and Running Gait Parameters
    Jaen-Carrillo, Diego
    Ruiz-Alias, Santiago A.
    Chicano-Gutierrez, Jose M.
    Ruiz-Malagon, Emilio J.
    Roche-Seruendo, Luis E.
    Garcia-Pinillos, Felipe
    SENSORS, 2022, 22 (09)
  • [7] Test-retest reliability of quantitative gait analysis in people with Mild Cognitive Impairment
    Montero-Odasso, M. M.
    Casas, A.
    Hansen, K. T.
    Gutmanis, I.
    Wells, J.
    Bilski, P.
    Borrie, M.
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2008, 56 (04) : S153 - S153
  • [8] TEST-RETEST RELIABILITY OF ACTIVITY VECTOR ANALYSIS
    MERENDA, PF
    CLARKE, WV
    PSYCHOLOGICAL REPORTS, 1959, 5 (01) : 27 - 30
  • [9] Test-Retest Reliability of Discrete Gait Parameters in Children With Cerebral Palsy
    Klejman, Susan
    Andrysek, Jan
    Dupuis, Annie
    Wright, Virginia
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 91 (05): : 781 - 787
  • [10] Test-Retest Reliability of the Effect of Prism on Gait Utilizing GaitRite Technology
    Yevseyenkov, Vladimir
    Frison, Kaitlin
    Wood, Mark
    Harrison, Wendy Watkins
    Scott, Jeffrey
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)