Test-retest reliability of trunk accelerometric gait analysis

被引:191
作者
Henriksen, M
Lund, H
Moe-Nilssen, R
Bliddal, H
Danneskiod-Samsoe, B
机构
[1] Frederiksberg Univ Hosp, Parker Inst, DK-2000 Frederiksberg, Denmark
[2] Univ Bergen, Natl Inst Publ Hlth & Primary Hlth Care, Balance & Gait Unit, N-5009 Bergen, Norway
关键词
gait analysis; accelerometry; reliability; human locomotion; motor control;
D O I
10.1016/S0966-6362(03)00069-9
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The purpose of this study was to determine the test-retest reliability of a trunk accelerometric gait analysis in healthy subjects. Accelerations were measured during walking using a triaxial accelerometer mounted on the lumbar spine of the subjects. Six men and 14 women (mean age 35.2; range 18-57) underwent the same protocol on 2 consecutive days. The raw acceleration signals from six self-selected walking speeds were transformed into a horizontal-vertical coordinate system to remove unwanted variability caused by gravity. Acceleration root mean square values, cadences, step and stride lengths were then computed and interpolated using quadratic curve fits and point estimates were calculated at a standardised walking speed of 1.35 m/s. Relative reliability was determined using two models of intraclass correlation coefficients (ICC(1,1) and ICC(3,1)) to assess any systematic shifts and absolute reliability was determined using measurement error (ME). The results of the study showed high ICC values (0.77-0.96) and ME values of 0.007-0.01g for mean acceleration; 0.009 m for step lengths; 0.022 m for stride length and 1.644 step/min for cadences. In conclusion, the method was found to be reliable and may have a definite potential in clinical gait analysis. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:288 / 297
页数:10
相关论文
共 25 条
  • [1] Auvinet B, 1999, REV RHUM, V66, P389
  • [2] Reference data for normal subjects obtained with an accelerometric device
    Auvinet, B
    Berrut, G
    Touzard, C
    Moutel, L
    Collet, N
    Chaleil, D
    Barrey, E
    [J]. GAIT & POSTURE, 2002, 16 (02) : 124 - 134
  • [3] Bussmann JBJ, 2000, MED SCI SPORT EXER, V32, P1462
  • [4] Quantification of physical activities by means of ambulatory accelerometry: A validation study
    Bussmann, JBJ
    Tulen, JHM
    van Herel, ECG
    Stam, HJ
    [J]. PSYCHOPHYSIOLOGY, 1998, 35 (05) : 488 - 496
  • [5] Ambulatory accelerometry to quantify motor behaviour in patients after failed back surgery: a validation study
    Bussmann, JBJ
    van de Laar, YM
    Neeleman, MP
    Stam, HJ
    [J]. PAIN, 1998, 74 (2-3) : 153 - 161
  • [6] MEASUREMENT OF GAIT BY ACCELEROMETER AND WALKWAY - A COMPARISON STUDY
    CURRIE, G
    RAFFERTY, D
    DUNCAN, G
    BELL, F
    EVANS, AL
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (06) : 669 - 670
  • [7] DOMBHOLDT E, 2000, PHYS THERAPY RES PRI, P221
  • [8] RECORDING ACCELERATIONS IN BODY MOVEMENTS
    EVANS, AL
    DUNCAN, G
    GILCHRIST, W
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1991, 29 (01) : 102 - 104
  • [9] Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments
  • [10] Validity of accelerometry for the assessment of moderate intensity physical activity in the field
    Hendelman, D
    Miller, K
    Bagget, C
    Debold, E
    Freedson, P
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) : S442 - S449