Decreased concentration of exhaled nitric oxide (NO) in patients with cystic fibrosis

被引:1
|
作者
Grasemann, H [1 ]
Michler, E [1 ]
Wallot, M [1 ]
Ratjen, F [1 ]
机构
[1] UNIV ESSEN GESAMTHSCH, DEPT PEDIAT, ESSEN, GERMANY
关键词
nitric oxide; single breath measurements; cystic fibrosis; lung disease; airway inflammation;
D O I
10.1002/(SICI)1099-0496(199709)24:3<173::AID-PPUL2>3.0.CO;2-O
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Nitric oxide (NO) is produced by various cell types in the human respiratory tract. Endogenously produced nitric oxide is detectable in the exhaled air of healthy individuals. Exhaled NO has been shown to be increased in airway inflammation, most probably due to cytokine-mediated activation of NO synthases. To assess whether NO can serve as a marker of inflammation in cystic fibrosis (CF) lung disease, we measured exhaled NO in CF patients with a chemiluminescence analyser. Single breath measurements were performed in 27 stable CF patients (age range, 6-40 years) and 30 non-smoking controls (age range, 6-37 years). Exhaled NO concentrations were 9.1 +/- 3.6 ppb in the controls and 5.9 +/- 2.6 ppb (P < 0.001) in CF patients. To account for room air NO concentrations on the measurement of exhaled NO, we also calculated the difference between exhaled NO and ambient NO concentrations. Difference values were also significantly lower in CF compared with controls (P < 0.0001). In CF patients there was a positive correlation between exhaled NO and forced vital capacity (r = 0.43, P = 0.033), suggesting that exhaled NO is lower in patients with severe lung disease than in those with mild disease. We conclude that measurements of exhaled NO in CF does not reflect activity of CF airway inflammation. The decreased concentrations of exhaled NO may be due to inhibitory effects of inflammatory cytokines on NO synthases in the airways and alveolar epithelial cells or to increased retention in airway secretions. (C) 1997 Wiley-Liss. Inc.
引用
收藏
页码:173 / 177
页数:5
相关论文
共 50 条
  • [31] Increased carbon monoxide in exhaled air of patients with cystic fibrosis
    Paredi, P
    Shah, PL
    Montuschi, P
    Sullivan, P
    Hodson, ME
    Kharitonov, SA
    Barnes, PJ
    THORAX, 1999, 54 (10) : 917 - 920
  • [32] Exhaled carbon monoxide is not elevated in patients with asthma or cystic fibrosis
    Zetterquist, W
    Marteus, H
    Johannesson, M
    Nordvall, SL
    Ihre, E
    Lundberg, JON
    Alving, K
    EUROPEAN RESPIRATORY JOURNAL, 2002, 20 (01) : 92 - 99
  • [33] Dornase alpha and exhaled NO in cystic fibrosis
    Grasemann, H
    Lax, H
    Treseler, JW
    Colin, AA
    PEDIATRIC PULMONOLOGY, 2004, 38 (05) : 379 - 385
  • [34] Reduction of neuronal and inducible nitric oxide synthase gene expression in patients with cystic fibrosis
    Dötsch, J
    Puls, J
    Klimek, T
    Rascher, W
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2002, 259 (04) : 222 - 226
  • [35] Exhaled nitric oxide in pediatric patients with respiratory disease
    Rachel, Marta
    Biesiadecki, Marek
    Aebisher, David
    Galiniak, Sabina
    JOURNAL OF BREATH RESEARCH, 2019, 13 (04)
  • [36] Compassionate Nitric Oxide Adjuvant Treatment of Persistent Mycobacterium Infection in Cystic Fibrosis Patients
    Yaacoby-Bianu, Karin
    Gur, Michal
    Toukan, Yazeed
    Nir, Vered
    Hakim, Fahed
    Geffen, Yuval
    Bentur, Lea
    PEDIATRIC INFECTIOUS DISEASE JOURNAL, 2018, 37 (04) : 336 - 338
  • [37] Alveolar, but not bronchial nitric oxide production is elevated in cystic fibrosis
    Suri, Ranjan
    Paraskakis, Emmanouil
    Bush, Andrew
    PEDIATRIC PULMONOLOGY, 2007, 42 (12) : 1215 - 1221
  • [38] Nitric Oxide and L-Arginine Deficiency in Cystic Fibrosis
    Grasemann, Hartmut
    Ratjen, Felix
    CURRENT PHARMACEUTICAL DESIGN, 2012, 18 (05) : 726 - 736
  • [39] Exhaled Nitric Oxide in COPD
    Bikov, Andras
    Meszaros, Martina
    Lazar, Zsofia
    CURRENT RESPIRATORY MEDICINE REVIEWS, 2019, 15 (02) : 71 - 78
  • [40] Nitric oxide, iNOS, and inflammation in cystic fibrosis
    Downey, D
    Elbom, MJS
    JOURNAL OF PATHOLOGY, 2000, 190 (02) : 115 - 116