Intercomparison of satellite and ground-based ozone total column measurements

被引:13
作者
Virolainen, Ya. A. [1 ]
Timofeyev, Yu. M. [1 ]
Poberovsky, A. V. [1 ]
机构
[1] St Petersburg State Univ, Fac Phys, St Petersburg 198504, Russia
基金
俄罗斯基础研究基金会;
关键词
ozone total column; atmospheric remote sensing methods; Fourier spectroscopy; satellite measurements validation; FTIR; OMI;
D O I
10.1134/S0001433813090235
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Ozone total column (OTC) measurements made in 2009-2012 near St. Petersburg by a Fourier Transform Infrared (FTIR) spectrometer (Peterhof, St. Petersburg State University (SPbSU)), an M-124 filter ozonometer, and a Dobson spectrophotometer (Voeikovo, MGO), as well as measurements made by a spectrometer ozone monitoring instrument (OMI) (onboard the AURA satellite) have been analyzed and compared. Comparisons have been performed both between ensembles of ground-based measurement data, as well as between ground-based and satellite data. It has been shown that the standard deviation for all devices is 2.5-4.5%; here, the FTIR and Dobson instruments measuring the direct sun are in better agreement with OMI than the M-124 ozonometer measuring the zenith-scattered solar radiation as well. A seasonal cycle in discrepancy with amplitude of 1.5% has been detected between two series of OTC measurements made by M-124 and OMI instruments for a total of 850 days. In fall and winter, the ground-based measurements underestimate the OTC values in comparison with satellite data; in spring and summer, the situation is reversed: ground-based data overestimate the OTC values. Also, it has been revealed that FTIR measurements systematically overestimate the OTC values in comparison with other instruments: from 1.4% (for Dobson) to 3.4% (for OMI). Taking into account the spatial and temporal discrepancy of independent ensembles of measurements and an analysis of standard deviations between ground-based and satellite measurement data, the FTIR spectrometer (SPbSU) can be recommended for OTC satellite data validation.
引用
收藏
页码:993 / 1001
页数:9
相关论文
共 19 条
[1]  
[Anonymous], 2003, 47 WMO
[2]   Validation of OMI-TOMS and OMI-DOAS total ozone column using five Brewer spectroradiometers at the Iberian peninsula [J].
Anton, M. ;
Lopez, M. ;
Vilaplana, J. M. ;
Kroon, M. ;
McPeters, R. ;
Banon, M. ;
Serrano, A. .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2009, 114
[3]   Ten years of GOME/ERS2 total ozone data - The new GOME data processor (GDP) version 4: 2. Ground-based validation and comparisons with TOMS V7/V8 [J].
Balis, D. ;
Lambert, J. -C. ;
Van Roozendael, M. ;
Spurr, R. ;
Loyola, D. ;
Livschitz, Y. ;
Valks, P. ;
Amiridis, V. ;
Gerard, P. ;
Granville, J. ;
Zehner, C. .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2007, 112 (D7)
[4]  
Bhartia P.K., 2002, NASA TECH PUB
[5]   REPLACEMENT FOR DOBSON SPECTROPHOTOMETER QUESTIONABLE - PRESIDENTIAL-ADDRESS [J].
BREWER, AW .
PURE AND APPLIED GEOPHYSICS, 1973, 106 (5-7) :919-927
[6]   Comparison of OMI ozone and UV irradiance data with ground-based measurements at two French sites [J].
Buchard, V. ;
Brogniez, C. ;
Auriol, F. ;
Bonnel, B. ;
Lenoble, J. ;
Tanskanen, A. ;
Bojkov, B. ;
Veefkind, P. .
ATMOSPHERIC CHEMISTRY AND PHYSICS, 2008, 8 (16) :4517-4528
[7]  
Dobson G. M. B., 1957, Annals of the International Geophysical Year, VPart1, P46
[8]  
Gushchin G.P., 1987, T 6 VSES S 15 17 MAY, P49
[9]   Intercomparison of retrieval codes used for the analysis of high-resolution, ground-based FTIR measurements [J].
Hase, F ;
Hannigan, JW ;
Coffey, MT ;
Goldman, A ;
Höpfner, M ;
Jones, NB ;
Rinsland, CP ;
Wood, SW .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2004, 87 (01) :25-52
[10]  
Ialongo I., 2008, ATMOS CHEM PHYS DISC, P2381