Ceramic Materials as Bearing Surfaces for Total Hip Arthroplasty

被引:63
作者
D'Antonio, James A. [1 ]
Sutton, Kate [1 ]
机构
[1] Acad Resources, Stryker Orthopaed, Mahwah, NJ USA
关键词
FEMORAL-HEAD; POLYETHYLENE WEAR; ON-POLYETHYLENE; COBALT-CHROMIUM; SURVIVORSHIP; SIMULATOR; DAMAGE;
D O I
10.5435/00124635-200902000-00002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
During the past decade, advances in total hip arthroplasty component design have produced implants with reliable clinical results in regard to fixation. The foremost unresolved challenge has been the development of bearing surfaces that can withstand the higher demands of younger and more active patients. New alternative bearings with superior wear characteristics that minimize debris include ceramic-on-ceramic, metal-on-metal, and highly cross-linked polyethylenes in combination with ceramic or metal. Alumina-on-alumina ceramic bearings are extremely hard and scratch resistant and provide superior lubrication and wear resistance compared with other bearing surfaces in clinical use. Survivorship revision for any reason for the alumina ceramic bearings at 10 years was significantly higher compared with metal-on-polyethylene. Bearings currently being studied because of their encouraging wear performance in the laboratory are an alumina matrix (82% alumina, 17% zirconia, 0.3% chromium oxide), zirconium oxide, and ceramic-on-cobalt-chromium.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 32 条
  • [1] Revision total hip arthroplasty performed after fracture of a ceramic femoral head - A multicenter survivorship study
    Allain, J
    Roudot-Thoraval, F
    Delecrin, J
    Anract, P
    Migaud, H
    Goutallier, D
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (05) : 825 - 830
  • [2] Concerns about ceramics in THA
    Barrack, RL
    Barak, C
    Skinner, HB
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) : 73 - 79
  • [3] Arthroplasty options for the young patient
    Bourne, RB
    Barrack, R
    Rorabeck, CH
    Salehi, A
    Good, V
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) : 159 - 167
  • [4] Clarke IC, 2000, CLIN ORTHOP RELAT R, P34
  • [5] CLARKE IC, 1992, CLIN ORTHOP RELAT R, P19
  • [6] CLARKE IC, 1994, BONE IMPLANT INTERFA, P203
  • [7] Alumina ceramic bearings for total hip arthroplasty - Five-year results of a prospective randomized study
    D'Antonio, J
    Capello, W
    Manley, M
    Naughton, M
    Sutton, K
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) : 164 - 171
  • [8] A titanium-encased alumina ceramic bearing for total hip arthroplasty - 3-to 5-year results
    D'Antonio, JA
    Capello, WN
    Manley, MT
    Naughton, M
    Sutton, K
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) : 151 - 158
  • [9] DAntonio JA, 2006, SEMIN ARTHROPLAST, V17, P146
  • [10] Wear of a highly cross-linked polyethylene liner associated with metallic deposition on a ceramic femoral head
    Della Valle, AG
    Doty, S
    Gradl, G
    Labissiere, A
    Nestor, BJ
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (04) : 532 - 536