Study on the united glucose oxidase electrode constructed by composite electrode

被引:0
作者
Yu, XJ [1 ]
Liping, H [1 ]
Ding, Z [1 ]
机构
[1] Harbin Inst Technol, Dept Environm Sci & Engn, Harbin 150001, Peoples R China
关键词
biosensor; enzyme electrode; glucose oxidase;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A novel type of united glucose oxidase (GOD) electrode was designed. Glucose oxidase and ferrocene (Fc), which was a mediator, were added into the composite electrode that was constructed by graphite powder, acetylene black, and epoxy resin. These three materials in composite electrode kept constant proportion in weight. And the optimum amounts of GOD and Fc among united enzyme electrode were 5% and 2%, respectively. The glucose was detected linearly in the concentration range 0.01-9.0 mM with a 20-s steady-state response time and 36 nA/mM of the sensitivity at 0.15 V applied potential. And electrode fouling problem and the response current from the interferents were avoided. The response current of the united GOD electrode had no obvious deterioration within 80 days when stored at 4degreesC in a refrigerator. The detecting results of human serum by the united GOD electrode had good consistency with that by standard enzyme method. The maximum deviation between these two detecting values was 5%. It might be used for detecting the blood sugar in clinical assay.
引用
收藏
页码:721 / 725
页数:5
相关论文
共 8 条
  • [1] Development of renewable surface biosensors to meet industrial needs for measurement of glucose in fruit juices
    Boujtita, M
    Boitard, M
    El Murr, N
    [J]. BIOSENSORS & BIOELECTRONICS, 1999, 14 (06) : 545 - 553
  • [2] Screen-printable surfactant-induced sol-gel graphite composites for electrochemical sensors
    Guo, YZ
    Guadalupe, AR
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1998, 46 (03) : 213 - 219
  • [3] SENSORS BASED ON CARBON-PASTE IN ELECTROCHEMICAL ANALYSIS - A REVIEW WITH PARTICULAR EMPHASIS ON THE PERIOD 1990-1993
    KALCHER, K
    KAUFFMANN, JM
    WANG, J
    SVANCARA, I
    VYTRAS, K
    NEUHOLD, C
    YANG, Z
    [J]. ELECTROANALYSIS, 1995, 7 (01) : 5 - 22
  • [4] POLISHABLE AND ROBUST BIOLOGICAL ELECTRODE SURFACES
    WANG, J
    VARUGHESE, K
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (03) : 318 - 320
  • [5] Wiseman A, 1995, HDB ENZYME BIOTECHNO
  • [6] YU XJ, 1999, J HARBIN I TECHNOLOG, V31, P72
  • [7] Flow injection analytical system for glucose with screen-printed enzyme biosensor incorporating Os-complex mediator
    Zhang, CX
    Gao, Q
    Aizawa, M
    [J]. ANALYTICA CHIMICA ACTA, 2001, 426 (01) : 33 - 41
  • [8] Evaluation of substituted-1,10-phenanthroline complexes of osmium as mediator for glucose oxidase of Aspergillus Niger
    Zhang, CX
    Haruyama, T
    Kobatake, E
    Aizawa, M
    [J]. ANALYTICA CHIMICA ACTA, 2000, 408 (1-2) : 225 - 232