Unrestrained acoustic plethysmograph for measuring tidal volume in mice

被引:11
作者
Reynolds, Jeffrey S. [1 ]
Frazer, David G. [1 ]
机构
[1] NIOSH, Pathol & Physiol Res Branch, Hlth Effects Lab Div, Morgantown, WV 26505 USA
关键词
Helmholtz resonator; whole-body plethysmography; barometric plethysmography; gas compression;
D O I
10.1007/s10439-006-9159-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The traditional method for measurement of tidal volume in unrestrained mice relies on pressure changes induced by a freely respiring animal in a whole body plethysmograph. These changes have been assumed to be the result of thermo-hygrometric differences between respired air and gas within the chamber. It is known, however, that gas compression in the lung can also contribute significantly to changes in plethysmograph pressure. This study describes an acoustic plethysmograph for mice that is capable of measuring the tidal volume time series without the errors associated with the traditional method. The plethysmograph was designed as a resonating cavity at a fixed frequency. It had a sharp resonant peak and was tuned so that changes in body volume produced nearly linear changes in sound amplitude. The plethysmograph was tested with a water filled balloon connected to a syringe pump. The volume of the balloon was varied as a triangle wave with an amplitude of 250 mu L. The RMS error between measured and delivered volume was 4.43 mu L. A volume step test, performed to assess the response time of the system, showed that the plethysmograph responded in less than one millisecond.
引用
收藏
页码:1494 / 1499
页数:6
相关论文
共 19 条
[11]   SOUND AND ITS SIGNIFICANCE FOR LABORATORY-ANIMALS [J].
GAMBLE, MR .
BIOLOGICAL REVIEWS OF THE CAMBRIDGE PHILOSOPHICAL SOCIETY, 1982, 57 (AUG) :395-421
[12]   Noninvasive measurement of airway responsiveness in allergic mice using barometric plethysmography [J].
Hamelmann, E ;
Schwarze, J ;
Takeda, K ;
Oshiba, A ;
Larsen, GL ;
Irvin, CG ;
Gelfand, EW .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 156 (03) :766-775
[14]  
JIMINEX OSV, 1993, J BIOMED ENG, V15, P91
[15]   Airway resistance due to alveolar gas compression measured by barometric plethysmography in mice [J].
Lai-Fook, SJ ;
Lai, YL .
JOURNAL OF APPLIED PHYSIOLOGY, 2005, 98 (06) :2204-2218
[16]   A reevaluation of the validity of unrestrained plethysmography in mice [J].
Lundblad, LKA ;
Irvin, CG ;
Adler, A ;
Bates, JHT .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (04) :1198-1207
[17]  
Lyons R. G., 2004, UNDERSTANDING DIGITA
[18]   Interpreting Penh in mice [J].
Mitzner, W ;
Tankersley, C .
JOURNAL OF APPLIED PHYSIOLOGY, 2003, 94 (02) :828-831
[19]   BODY VOLUME AND FAT-FREE MASS DETERMINATIONS BY ACOUSTIC PLETHYSMOGRAPHY [J].
SHENG, HP ;
ADOLPH, AL ;
SMITH, EO ;
GARZA, C .
PEDIATRIC RESEARCH, 1988, 24 (01) :85-89