Using a multi-method approach based on soil radon deficit, resistivity, and induced polarization measurements to monitor non-aqueous phase liquid contamination in two study areas in Italy and India

被引:21
作者
Castelluccio, Mauro [1 ]
Agrahari, Sudha [2 ]
De Simone, Gabriele [1 ]
Pompilj, Francesca [1 ]
Lucchetti, Carlo [1 ]
Sengupta, Debashish [2 ]
Galli, Gianfranco [3 ]
Friello, Pierluigi [4 ]
Curatolo, Pierpaolo [5 ]
Giorgi, Riccardo [5 ]
Tuccimei, Paola [1 ]
机构
[1] Univ Roma Tre, Dipartimento Sci, Largo San Leonardo Murialdo 1, I-00146 Rome, Italy
[2] Indian Inst Technol, Dept Geol & Geophys, Kharagpur 721302, W Bengal, India
[3] Ist Nazl Geofis & Vulcanol, Sez Roma 1, Via Vigna Murata 605, I-00143 Rome, Italy
[4] Polo Geol Srl, Lungotevere Inventori 114 B, I-00146 Rome, Italy
[5] Golder Associates, Via Sante Bargellini 4, I-00157 Rome, Italy
关键词
NAPL contamination; Soil radon; Soil electrical resistivity; Soil induced polarization; Environmental monitoring; Italy; India; NAPL CONTAMINATION; TRACER; FIELD; REMEDIATION; PARTITION; INVERSION; WATER; ROME;
D O I
10.1007/s11356-018-1429-0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Geochemical and geophysical surveys employing radon deficit, resistivity, and induced polarization (IP) measurements were undertaken on soil contaminated with non-aqueous phase liquids (NAPLs) in two different sites in India and in Italy. Radon deficit, validated through the comparison with average soil radon in reference unpolluted areas, shows the extension of contamination in the upper part of the unsaturated aquifers. In site 1 (Italy), the spill is not recent. A residual film of kerosene covers soil grains, inhibiting their chargeability and reducing electrical resistivity difference with background unpolluted areas. No correlation between the two parameters is observed. Soil volatile organic compounds (VOCs) concentration is not linked with radon deficit, supporting the old age of the spillage. NAPL pollution in sites 2a and 2b (India) is more recent and probably still active, as demonstrated by higher values of electrical resistivity. A good correlation with IP values suggests that NAPL is still distributed as droplets or as a continuous phase in the pores, strengthening the scenario of a fresh spill or leakage. Residual fraction of gasoline in the pore space of sites 2a and 2b is respectively 1.5 and 11.8 kg per cubic meter of terrain. This estimation is referred to the shallower portion of the unsaturated aquifer. Electrical resistivity is still very high indicating that the gasoline has not been strongly degraded yet. Temperature and soil water content influence differently radon deficit in the three areas, reducing soil radon concentration and partly masking the deficit in sites 2a and 2b.
引用
收藏
页码:12515 / 12527
页数:13
相关论文
共 29 条
[1]   Two-dimensional individual and joint inversion of three- and four-electrode array dc resistivity data [J].
Candansayar, M. E. .
JOURNAL OF GEOPHYSICS AND ENGINEERING, 2008, 5 (03) :290-300
[2]   Hazardous gas emissions from the flanks of the quiescent Colli Albani volcano (Rome, Italy) [J].
Carapezza, M. L. ;
Barberi, F. ;
Ranaldi, M. ;
Ricci, T. ;
Tarchini, L. ;
Barrancos, J. ;
Fischer, C. ;
Granieri, D. ;
Lucchetti, C. ;
Melian, G. ;
Perez, N. ;
Tuccimei, P. ;
Vogel, A. ;
Weber, K. .
APPLIED GEOCHEMISTRY, 2012, 27 (09) :1767-1782
[3]   A new technique to measure in situ soil gas permeability [J].
Castelluccio, M. ;
De Simone, G. ;
Lucchetti, C. ;
Moroni, M. ;
Salvati, F. ;
Tuccimei, P. .
JOURNAL OF GEOCHEMICAL EXPLORATION, 2015, 148 :56-59
[4]  
Central Groundwater Board Ministry ofWater Resources-Government of India, 2014, GROUND WAT YB W BE D
[5]  
Chatterjee S, 2003, INDIAN J GEOGR ENV, V8, P82
[6]   Temporal geophysical signatures from contaminant-mass remediation [J].
Che-Alota, Vukenkeng ;
Atekwana, Estella A. ;
Atekwana, Eliot A. ;
Sauck, William A. ;
Werkema, D. Dale, Jr. .
GEOPHYSICS, 2009, 74 (04) :B113-B123
[7]  
Chiodini G, 2007, RESULTS INGV DPC V5
[8]   A numerical comparison of 2D resistivity imaging with 10 electrode arrays [J].
Dahlin, T ;
Zhou, B .
GEOPHYSICAL PROSPECTING, 2004, 52 (05) :379-398
[9]   Correcting for H2O interference using a RAD7 electrostatic collection-based silicon detector [J].
De Simone, G. ;
Lucchetti, C. ;
Galli, G. ;
Tuccimei, P. .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2016, 162 :146-153
[10]   Soil radon survey to assess NAPL contamination from an ancient spill. Do kerosene vapors affect radon partition ? [J].
De Simone, Gabriele ;
Lucchetti, Carlo ;
Pompilj, Francesca ;
Galli, Gianfranco ;
Tuccimei, Paola ;
Curatolo, Pierpaolo ;
Giorgi, Riccardo .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2017, 171 :138-147