A Comparison of Internet Monitoring with Continuous Glucose Monitoring in Insulin-Requiring Type 2 Diabetes Mellitus (Withdrawn Publication)

被引:13
|
作者
Tildesley, Hugh D. [1 ,2 ]
Wright, Anthony M. [3 ]
Chan, Jeremy H. M. [4 ]
Mazanderani, Adel B. [5 ]
Ross, Stuart A. [6 ]
Tildesley, Hamish G. [7 ]
Lee, Augustine M. [2 ]
Tang, Tricia S. [2 ]
White, Adam S. [1 ,2 ]
机构
[1] St Pauls Hosp, Dept Endocrinol & Metab, Vancouver, BC V6Z 1Y6, Canada
[2] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[3] Univ Victoria, Victoria, BC, Canada
[4] Vanderbilt Univ, Sch Med, Nashville, TN 37212 USA
[5] St Georges Univ, St Georges, Grenada
[6] Univ Calgary, Calgary, AB, Canada
[7] Dartmouth Coll, Hanover, NH 03755 USA
关键词
Internet-based glucose monitoring; real-time continuous glucose monitoring; remote monitoring; type; 2; diabetes; BLOOD-GLUCOSE;
D O I
10.1016/j.jcjd.2013.05.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare the effects of real-time continuous glucose monitoring (RT-CGM) and an Internet blood glucose monitoring system (IBGMS) on glycated hemoglobin levels in patients with type 2 diabetes mellitus treated with insulin. Methods: Fifty-seven patients with type 2 diabetes treated with insulin were assigned randomly to 1 of 2 groups. Group 1 had the results of their self-monitoring of blood glucose level monitored biweekly using an IBGMS. Group 2 used RT-CGM and were monitored biweekly. Both groups used a secure website to upload data and to receive feedback from their endocrinologist. A1C and laboratory test results were collected at 0, 3 and 6 months. Results: The baseline parameters were not significantly different. After a 6-month follow-up period, both IBGMS and RT-CGM showed significant within-group improvements in A1C level. In the IBGMS group, the A1C level decreased from 8.79%+/- 1.25% to 7.96%+/- 1.30% (p<0.05). The RT-CGM group decreased from 8.80%+/- 1.37% to 7.49%+/- 0.70% (p<0.001). IBGMS and RT-CGM did not show significantly different A1C levels at baseline, 3 and 6 months (p>0.05). Conclusions: The use of both IBGMS and RT-CGM significantly improved A1C levels in patients with type 2 diabetes treated with insulin in a randomized trial over a 6-month period. There were no significant differences in A1C values between groups after 6 months. (C) 2013 Canadian Diabetes Association
引用
收藏
页码:305 / 308
页数:4
相关论文
共 50 条
  • [31] Real-time continuous glucose monitoring versus internet-based blood glucose monitoring in adults with type 2 diabetes: A study of treatment satisfaction
    Tang, Tricia S.
    Digby, Erica M.
    Wright, Anthony M.
    Chan, Jeremy H. M.
    Mazanderani, Adel B.
    Ross, Stuart A.
    Tildesley, Hamish G.
    Lee, Augustine M.
    White, Adam S.
    Tildesley, Hugh D.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2014, 106 (03) : 481 - 486
  • [32] The Effect of Financial Incentives on Adherence to Glucose Self-Monitoring during Pregnancy among Patients with Insulin-Requiring Diabetes: A Randomized Clinical Trial
    Wernimont, Sarah A.
    Fleener, Diedre
    Summers, Karen M.
    Deonovic, Benjamin
    Syrop, Craig H.
    Andrews, Janet, I
    AMERICAN JOURNAL OF PERINATOLOGY, 2024, 41 : e259 - e266
  • [33] The Use of Continuous Glucose Monitoring in Patients with Type 2 Diabetes
    Meade, Lisa T.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2012, 14 (02) : 190 - 195
  • [34] Satisfaction with Continuous Glucose Monitoring in Pregnant Patients with Type 1 and Type 2 Diabetes
    Shrestha, Kevin S.
    Battarbee, Ashley N.
    AMERICAN JOURNAL OF PERINATOLOGY, 2024,
  • [35] Comparison between preprandial vs. postprandial insulin aspart in patients with type 1 diabetes on insulin pump and real-time continuous glucose monitoring
    Thuillier, Philippe
    Sonnet, Emmanuel
    Alavi, Zarrin
    Roudaut, Nathalie
    Nowak, Emmanuel
    Dion, Angelina
    Kerlan, Veronique
    DIABETES-METABOLISM RESEARCH AND REVIEWS, 2018, 34 (06)
  • [36] Effectiveness of continuous glucose monitoring in patient management of Type 2 Diabetes Mellitus: an umbrella review of systematic reviews from 2011 to 2024
    Tan, Yong Yi
    Suan, Enhui
    Koh, Gerald Choon Huat
    Suhairi, Suhana Binte
    Tyagi, Shilpa
    ARCHIVES OF PUBLIC HEALTH, 2024, 82 (01)
  • [37] Cost-Effectiveness of a Real-Time Continuous Glucose Monitoring System Versus Self-Monitoring of Blood Glucose in People with Type 2 Diabetes on Insulin Therapy in the UK
    Isitt, John J.
    Roze, Stephane
    Sharland, Helen
    Cogswell, Greg
    Alshannaq, Hamza
    Norman, Gregory J.
    Lynch, Peter M.
    DIABETES THERAPY, 2022, 13 (11-12) : 1875 - 1890
  • [38] Cost-effectiveness of continuous glucose monitoring and intensive insulin therapy for type 1 diabetes
    McQueen R.B.
    Ellis S.L.
    Campbell J.D.
    Nair K.V.
    Sullivan P.W.
    Cost Effectiveness and Resource Allocation, 9 (1)
  • [39] Continuous glucose monitoring in adults with type 2 diabetes: a systematic review and meta-analysis
    Jancev, Milena
    Vissers, Tessa A. C. M.
    Visseren, Frank L. J.
    van Bon, Arianne C.
    Serne, Erik H.
    DeVries, J. Hans
    de Valk, Harold W.
    van Sloten, Thomas T.
    DIABETOLOGIA, 2024, 67 (05) : 798 - 810
  • [40] Perspective of Continuous Glucose Monitoring-Based Interventions at the Various Stages of Type 2 Diabetes
    Ajjan, R. A.
    Seidu, S.
    Riveline, J. P.
    DIABETES THERAPY, 2024, 15 (08) : 1657 - 1672