Monte Carlo Evaluation of Auger Electron-Emitting Theranostic Radionuclides

被引:58
作者
Falzone, Nadia [1 ,2 ]
Fernandez-Varea, Jose M. [3 ]
Flux, Glenn [4 ]
Vallis, Katherine A. [1 ]
机构
[1] Univ Oxford, Dept Oncol, CR UK MRC Oxford Inst Radiat Oncol, Oxford OX3 7LJ, England
[2] Tshwane Univ Technol, Dept Biomed Sci, Pretoria, South Africa
[3] Univ Barcelona, Fac Fis ECM & ICC, Barcelona, Spain
[4] Royal Marsden NHSFT, Phys Dept, Sutton, Surrey, England
基金
英国医学研究理事会;
关键词
Auger electron emitters; cellular dosimetry; targeted radiotherapy; theranostics; Monte Carlo simulation; S values; dose point kernels; DOSE-POINT KERNELS; DOSIMETRY; RADIOTHERAPY; PENELOPE; EMITTERS; EMISSIONS; I-125; CODE;
D O I
10.2967/jnumed.114.153502
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Several radionuclides used in medical imaging emit Auger electrons, which, depending on the targeting strategy, either may be exploited for therapeutic purposes or may contribute to an unintentional mean absorbed dose burden. In this study, the virtues of 12 Auger electron-emitting radionuclides were evaluated in terms of cellular S values in concentric and eccentric cell-nucleus arrangements and by comparing their dose-point kernels. Methods: The Monte Carlo code PENELOPE was used to transport the full particulate spectrum of Ga-67, Br-80m, Zr-89, Nb-90, Tc-99m, In-111, (117)mSn, Sb-119, I-123, I-125, Pt-195m, and Tl-201 by means of event-by-event simulations. Cellular S values were calculated for varying cell and nucleus radii, and the effects of cell eccentricity on S values were evaluated. Dose-point kernels were determined up to 30 mu m. Energy deposition at DNA scales was also compared with an a emitter, Ra-223. Results: PENELOPE-determined S values were generally within 10% of MIRD values when the source and target regions strongly overlapped, that is, S(nucleus <- nucleus) configurations, but greater differences were noted for S(nucleus <- cytoplasm) and S(nucleus <- cell surface) configurations. Cell eccentricity had the greatest effect when the nucleus was small, compared with the cell size, and when the radiation sources were on the cell surface. Dose-point kernels taken together with the energy spectra of the radionuclides can account for some of the differences in energy deposition patterns between the radionuclides. The energy deposition of most Auger electron emitters at DNA scales of 2 nm or less exceeded that of a monoenergetic 5.77-MeV alpha particle, but not for Ra-223. Conclusion: A single-cell dosimetric approach is required to evaluate the efficacy of individual radionuclides for theranostic purposes, taking cell geometry into account, with internalizing and noninternalizing targeting strategies.
引用
收藏
页码:1441 / 1446
页数:6
相关论文
共 36 条
  • [1] [Anonymous], 2011, PENELOPE 2011-A Code System for Monte Carlo Simulation of Electron and Photon Transport
  • [2] GENOMIC INSTABILITY IN CANCER Strategies to improve radiotherapy with targeted drugs
    Begg, Adrian C.
    Stewart, Fiona A.
    Vens, Conchita
    [J]. NATURE REVIEWS CANCER, 2011, 11 (04) : 239 - 253
  • [3] An investigation on the capabilities of the PENELOPE MC code in nanodosimetry
    Bernal, M. A.
    Liendo, J. A.
    [J]. MEDICAL PHYSICS, 2009, 36 (02) : 620 - 625
  • [4] Bernhardt P, 2001, ACTA ONCOL, V40, P602
  • [5] Calculation of electron and isotopes dose point kernels with FLUKA Monte Carlo code for dosimetry in nuclear medicine therapy
    Botta, F.
    Mairani, A.
    Battistoni, G.
    Cremonesi, M.
    Di Dia, A.
    Fasso, A.
    Ferrari, A.
    Ferrari, M.
    Paganelli, G.
    Pedroli, G.
    Valente, M.
    [J]. MEDICAL PHYSICS, 2011, 38 (07) : 3944 - 3954
  • [6] Britz-Cunningham SH, 2003, J NUCL MED, V44, P1945
  • [7] THE RANGE OF HIGH LET EFFECTS FROM I-125 DECAYS
    CHARLTON, DE
    [J]. RADIATION RESEARCH, 1986, 107 (02) : 163 - 171
  • [8] Amplification of DNA damage by a γH2AX-targeted radiopharmaceutical
    Cornelissen, Bart
    Darbar, Sonali
    Kersemans, Veerle
    Allen, Danny
    Falzone, Nadia
    Barbeau, Jody
    Smart, Sean
    Vallis, Katherine A.
    [J]. NUCLEAR MEDICINE AND BIOLOGY, 2012, 39 (08) : 1142 - 1151
  • [9] Cornelissen Bart, 2010, Curr Drug Discov Technol, V7, P263, DOI 10.2174/157016310793360657
  • [10] 111In-labeled trastuzumab (herceptin) modified with nuclear localization sequences (NLS):: An Auger electron-emitting radiotherapeutic agent for HER2/neu-amplified breast cancer
    Costantini, Danny L.
    Chan, Conrad
    Cai, Zhongli
    Vallis, Katherine A.
    Reilly, Raymond M.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (08) : 1357 - 1368