Fluid dynamics of aortic root dilation in Marfan syndrome

被引:20
作者
Querzoli, Giorgio [1 ]
Fortini, Stefania [2 ]
Espa, Stefania [2 ]
Costantini, Martina [2 ]
Sorgini, Francesca [2 ]
机构
[1] Univ Cagliari, DICAA, Cagliari, Italy
[2] Univ Roma La Sapienza, DICEA, I-00185 Rome, Italy
关键词
Aortic flow; Vortex dynamics; Fluid dynamics; Velocity mapping; Marfan syndrome; PULSATILE FLOW; IN-VITRO; ASCENDING AORTA; VALVE; HEART; DILATATION; DISSECTION; PATTERNS; DISTENSIBILITY; OSCILLATIONS;
D O I
10.1016/j.jbiomech.2014.06.025
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Aortic root dilation and propensity to dissection are typical manifestations of the Marfan Syndrome (MS), a genetic defect leading to the degeneration of the elastic fibres. Dilation affects the structure of the flow and, in turn, altered flow may play a role in vessel dilation, generation of aneurysms, and dissection. The aim of the present work is the investigation in-vitro of the fluid dynamic modifications occurring as a consequence of the morphological changes typically induced in the aortic root by MS. A mock-loop reproducing the left ventricle outflow tract and the aortic root was used to measure time resolved velocity maps on a longitudinal symmetry plane of the aortic root. Two dilated model aortas, designed to resemble morphological characteristics typically observed in MS patients, have been compared to a reference, healthy geometry. The aortic model was designed to quantitatively reproduce the change of aortic distensibility caused by MS. Results demonstrate that vorticity released from the valve leaflets, and possibly accumulating in the root, plays a fundamental role in redirecting the systolic jet issued from the aortic valve. The altered systolic flow also determines a different residual flow during the diastole. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3120 / 3128
页数:9
相关论文
共 47 条
[11]   Combined experimental and numerical analysis of the flow structure into the left ventricle [J].
Domenichini, F. ;
Querzoli, G. ;
Cenedese, A. ;
Pedrizzetti, G. .
JOURNAL OF BIOMECHANICS, 2007, 40 (09) :1988-1994
[12]   A Lagrangian investigation of the flow inside the left ventricle [J].
Espa, S. ;
Badas, M. G. ;
Fortini, S. ;
Querzoli, G. ;
Cenedese, A. .
EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2012, 35 :9-19
[13]   Three-dimensional structure of the flow inside the left ventricle of the human heart [J].
Fortini, S. ;
Querzoli, G. ;
Espa, S. ;
Cenedese, A. .
EXPERIMENTS IN FLUIDS, 2013, 54 (11)
[14]   Aortic Wall Shear Stress in Marfan Syndrome [J].
Geiger, Julia ;
Arnold, Raoul ;
Herzer, Lena ;
Hirtler, Daniel ;
Stankovic, Zoran ;
Russe, Max ;
Langer, Mathias ;
Markl, Michael .
MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (04) :1137-1144
[15]   Aortic flow patterns in patients with Marfan syndrome assessed by flow-sensitive four-dimensional MRI [J].
Geiger, Julia ;
Markl, Michael ;
Herzer, Lena ;
Hirtler, Daniel ;
Loeffelbein, Florian ;
Stiller, Brigitte ;
Langer, Mathias ;
Arnold, Raoul .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (03) :594-600
[16]   Mechanisms of aortic valve incompetence: Finite element modeling of aortic root dilatation [J].
Grande, KJ ;
Cochran, RP ;
Reinhall, PG ;
Kunzelman, KS .
ANNALS OF THORACIC SURGERY, 2000, 69 (06) :1851-1857
[17]   Experimental study of aortic flow in the ascending aorta via Particle Tracking Velocimetry [J].
Guelan, Utku ;
Luethi, Beat ;
Holzner, Markus ;
Liberzon, Alex ;
Tsinober, Arkady ;
Kinzelbach, Wolfgang .
EXPERIMENTS IN FLUIDS, 2012, 53 (05) :1469-1485
[18]   THE MARFAN-SYNDROME - ABNORMAL AORTIC ELASTIC PROPERTIES [J].
HIRATA, K ;
TRIPOSKIADIS, F ;
SPARKS, E ;
BOWEN, J ;
WOOLEY, CF ;
BOUDOULAS, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (01) :57-63
[19]   Evaluation of Marfan patients status post valve-sparing aortic root replacement with 4D flow [J].
Hope, Thomas A. ;
Kvitting, John-Peder Escobar ;
Hope, Michael D. ;
Miller, D. Craig ;
Markl, Michael ;
Herfkens, Robert J. .
MAGNETIC RESONANCE IMAGING, 2013, 31 (09) :1479-1484
[20]   Measurements of steady flow through a bileaflet mechanical heart valve using stereoscopic PIV [J].
Hutchison, Chris ;
Sullivan, Pierre ;
Ethier, C. Ross .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2011, 49 (03) :325-335