An LN2 cooled toroid resonator

被引:0
|
作者
Pschierer, C
Griswold, M
Lanz, T
Haase, A
机构
[1] Univ Wurzburg, D-97074 Wurzburg, Germany
[2] Rapid Biomed GMBH, D-97074 Wurzburg, Germany
关键词
cooled toroid resonator; high Q; liquid nitrogen;
D O I
10.1002/cmr.b.20006
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
(ISMRM2002:) A toroid cavity resonator for imaging on small, non lossy objects like plants at 7.05 T has been built. It is integrated into a cryostat, so that it can be cooled to 77K using liquid nitrogen. Cooled and uncooled measurements on the workbench and in the NMR spectrometer have been performed and compared. (C) 2004 Wiley Periodicals, Inc.
引用
收藏
页码:11 / 18
页数:8
相关论文
共 50 条
  • [1] Fabrication of plasmonic structures on LN2 cooled substrates
    Stefaniuk, Tomasz
    Wrobel, Piotr
    Szoplik, Tomasz
    ROMOPTO 2012: TENTH CONFERENCE ON OPTICS: MICRO- TO NANOPHOTONICS III, 2013, 8882
  • [2] Development and UHV testing of LN2 cooled Titanium Sublimation Pump
    Sindal, B. K.
    Kumar, K. V. A. N. P. S.
    Bansod, Tripti
    Shukla, S. K.
    INTERNATIONAL SYMPOSIUM ON VACUUM SCIENCE AND TECHNOLOGY AND ITS APPLICATION FOR ACCELERATORS (IVS 2012), 2012, 390
  • [3] Characterization of LN2 cooled LAAPDs for single photon counting applications
    Joehren, R.
    Anielski, D.
    Balgenort, M.
    Buglak, W.
    Hampf, D.
    Hannen, V.
    Weinheimer, C.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1750 - +
  • [4] Simulation of thermal distortion of DCM crystal indirectly cooled by LN2
    Wang Na-Xiu
    Zhu Yi
    Fu Yuan
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2006, 30 (08): : 802 - 805
  • [5] Simulation of thermal distortion of DCM crystal indirectly cooled by LN2
    Wang, Na-Xiu
    Zhu, Yi
    Fu, Yuan
    Kao Neng Wu Li Yu Ho Wu Li/High Energy Physics and Nuclear Physics, 2006, 30 (08): : 802 - 805
  • [6] NITROGEN MOLECULAR SPECTRA OF AIR FLUORESCENCE EMULATOR USING A LN2 COOLED CCD
    Maltezos, S.
    Fokitis, E.
    Gika, V.
    Fetfatzis, P.
    Koutelieris, G.
    Galanis, E.
    Maragos, N.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2010, 5 : 253 - 258
  • [7] CONSIDERATION OF SUB-COOLED LN2 CIRCULATION SYSTEM FOR HTS POWER EQUIPMENT
    Yoshida, S.
    Hirai, H.
    Nara, N.
    Nagasaka, T.
    Hirokawa, M.
    Okamoto, H.
    Hayashi, H.
    Shiohara, Y.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 1649 - 1656
  • [8] Design and development of LN2 cooled cryopump for application in high heat flux test facility
    Mukherjee, S. S.
    Gupta, V
    Panchal, P.
    Mishra, J. S.
    Nayak, P.
    Agarwal, J.
    Agravat, H.
    Dewasi, A.
    Dutta, R.
    Desai, A. B.
    Verma, S. K.
    Swamy, R.
    Mokariya, P.
    Patel, N.
    Patel, T.
    Belsare, S. M.
    Khirwadkar, S. S.
    Gangradey, R.
    FUSION ENGINEERING AND DESIGN, 2022, 184
  • [9] Square Exponent of Irrationality of ln2
    Polyanskii, A. A.
    MOSCOW UNIVERSITY MATHEMATICS BULLETIN, 2012, 67 (01) : 23 - 28
  • [10] Performance of LN2 transfer lines
    Lizon, Jean Louis
    Castillo, Roberto
    Fernandez Izquierdo, Patricia
    ADVANCES IN OPTICAL AND MECHANICAL TECHNOLOGIES FOR TELESCOPES AND INSTRUMENTATION V, 2022, 12188