Skinfold thickness affects the isometric knee extension torque evoked by Neuromuscular Electrical Stimulation

被引:19
|
作者
Medeiros, Flavia V. A. [1 ]
Vieira, Amilton [2 ]
Carregaro, Rodrigo L. [3 ]
Bottaro, Martim [1 ]
Maffiuletti, Nicola A. [4 ]
Durigan, Joao L. Q. [3 ]
机构
[1] Univ Brasalia UnB, Fac Educ Fis, Brasilia, DF, Brazil
[2] Univ Brasalia UnB, Fac Ciencias Saude, Brasilia, DF, Brazil
[3] Univ Brasalia UnB, Dept Fisioterapia, Brasilia, DF, Brazil
[4] Schulthess Klin, Neuromuscular Res Lab, Zurich, Switzerland
关键词
physical therapy; physical agents; electrotherapy; QUADRICEPS FEMORIS; ELECTRODE SIZE; HEALTHY WOMEN; WAVE-FORMS; MUSCLE; PAIN; DISCOMFORT; PERCEPTION; ALTERS; FAT;
D O I
10.1590/bjpt-rbf.2014.0114
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Subcutaneous adipose tissue may influence the transmission of electrical stimuli through to the skin, thus affecting both evoked torque and comfort perception associated with neuromuscular electrical stimulation (NMES). This could seriously affect the effectiveness of NMES for either rehabilitation or sports purposes. Objective: To investigate the effects of skinfold thickness (SFT) on maximal NMES current intensity, NMES-evoked torque, and NMES-induced discomfort. Method: First, we compared NMES current intensity, NMES-induced discomfort, and NMES-evoked torque between two subgroups of subjects with thicker (n= 10; 20.7 mm) vs. thinner (n= 10; 29.4 mm) SFT. Second, we correlated SFT to NMES current intensity, NMES-induced discomfort, and NMES-evoked knee extension torque in 20 healthy women. The NMES-evoked torque was normalized to the maximal voluntary contraction (MVC) torque. The discomfort induced by NMES was assessed with a visual analog scale (VAS). Results: NMES-evoked torque was 27.5% lower in subjects with thicker SFT (p=0.01) while maximal current intensity was 24.2% lower in subjects with thinner SFT (p=0.01). A positive correlation was found between current intensity and SFT (r=0.540, p=0.017). A negative correlation was found between NMES-evoked torque and SFT (r=-0.563, p=0.012). No significant correlation was observed between discomfort scores and SFT (r(s)=0.15, p=0.53). Conclusion: These results suggest that the amount of subcutaneous adipose tissue (as reflected by skinfold thickness) affected NMES current intensity and NMES-evoked torque, but had no effect on discomfort perception. Our findings may help physical therapists to better understand the impact of SFT on NMES and to design more rational stimulation strategies.
引用
收藏
页码:466 / 472
页数:7
相关论文
共 50 条
  • [41] Sex Differences In Neuromuscular Fatigability During Submaximal Isometric Knee Extension Exercise Post Stroke
    Zhou, Zhilun
    Alqahtani, Saad
    Nguyen, Jennifer
    Raab, Stephanie
    Kroll, Zachary
    Durand, Matthew
    Schmit, Brian
    Hunter, Sandra
    Hyngstrom, Alliston
    STROKE, 2022, 53
  • [42] Local tissue temperature effects on peak torque and muscular endurance during isometric knee extension
    Thornley, LJ
    Maxwell, NS
    Cheung, SS
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2003, 90 (5-6) : 588 - 594
  • [43] Normalized EMG to normalized torque relationship of vastus intermedius muscle during isometric knee extension
    Kohei Watanabe
    Hiroshi Akima
    European Journal of Applied Physiology, 2009, 106 : 665 - 673
  • [44] Neuromuscular trunk performance and spinal loading during a fatiguing isometric trunk extension with varying torque requirements
    Sparto, PJ
    Parnianpour, M
    Marras, WS
    Granata, KP
    Reinsel, TE
    Simon, S
    JOURNAL OF SPINAL DISORDERS, 1997, 10 (02): : 145 - 156
  • [45] Neuromuscular Fatigue at Task Failure and During Immediate Recovery after Isometric Knee Extension Trials
    Froyd, Christian
    Beltrami, Fernando G.
    Noakes, Timothy D.
    SPORTS, 2018, 6 (04):
  • [46] Local tissue temperature effects on peak torque and muscular endurance during isometric knee extension
    Leo J. Thornley
    Neil S. Maxwell
    Stephen S. Cheung
    European Journal of Applied Physiology, 2003, 90 : 588 - 594
  • [47] Normalized EMG to normalized torque relationship of vastus intermedius muscle during isometric knee extension
    Watanabe, Kohei
    Akima, Hiroshi
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2009, 106 (05) : 665 - 673
  • [48] The effect of neuromuscular electrical stimulation on arthritis knee pain in older adults with osteoarthritis of the knee
    Gaines, JM
    Metter, EJ
    Talbot, LA
    APPLIED NURSING RESEARCH, 2004, 17 (03) : 201 - 206
  • [49] ISOMETRIC AND ISOKINETIC KNEE EXTENSION AND FLEXION TORQUE IN MEN AND WOMEN AGED 20-70
    BORGES, O
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1989, 21 (01): : 45 - 53
  • [50] Neuromuscular responses to isometric, concentric and eccentric contractions of the knee extensors at the same torque-time integral
    Nicolas Royer
    Kazunori Nosaka
    Valentin Doguet
    Marc Jubeau
    European Journal of Applied Physiology, 2022, 122 : 127 - 139