Skinfold thickness affects the isometric knee extension torque evoked by Neuromuscular Electrical Stimulation

被引:21
作者
Medeiros, Flavia V. A. [1 ]
Vieira, Amilton [2 ]
Carregaro, Rodrigo L. [3 ]
Bottaro, Martim [1 ]
Maffiuletti, Nicola A. [4 ]
Durigan, Joao L. Q. [3 ]
机构
[1] Univ Brasalia UnB, Fac Educ Fis, Brasilia, DF, Brazil
[2] Univ Brasalia UnB, Fac Ciencias Saude, Brasilia, DF, Brazil
[3] Univ Brasalia UnB, Dept Fisioterapia, Brasilia, DF, Brazil
[4] Schulthess Klin, Neuromuscular Res Lab, Zurich, Switzerland
关键词
physical therapy; physical agents; electrotherapy; QUADRICEPS FEMORIS; ELECTRODE SIZE; HEALTHY WOMEN; WAVE-FORMS; MUSCLE; PAIN; DISCOMFORT; PERCEPTION; ALTERS; FAT;
D O I
10.1590/bjpt-rbf.2014.0114
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Subcutaneous adipose tissue may influence the transmission of electrical stimuli through to the skin, thus affecting both evoked torque and comfort perception associated with neuromuscular electrical stimulation (NMES). This could seriously affect the effectiveness of NMES for either rehabilitation or sports purposes. Objective: To investigate the effects of skinfold thickness (SFT) on maximal NMES current intensity, NMES-evoked torque, and NMES-induced discomfort. Method: First, we compared NMES current intensity, NMES-induced discomfort, and NMES-evoked torque between two subgroups of subjects with thicker (n= 10; 20.7 mm) vs. thinner (n= 10; 29.4 mm) SFT. Second, we correlated SFT to NMES current intensity, NMES-induced discomfort, and NMES-evoked knee extension torque in 20 healthy women. The NMES-evoked torque was normalized to the maximal voluntary contraction (MVC) torque. The discomfort induced by NMES was assessed with a visual analog scale (VAS). Results: NMES-evoked torque was 27.5% lower in subjects with thicker SFT (p=0.01) while maximal current intensity was 24.2% lower in subjects with thinner SFT (p=0.01). A positive correlation was found between current intensity and SFT (r=0.540, p=0.017). A negative correlation was found between NMES-evoked torque and SFT (r=-0.563, p=0.012). No significant correlation was observed between discomfort scores and SFT (r(s)=0.15, p=0.53). Conclusion: These results suggest that the amount of subcutaneous adipose tissue (as reflected by skinfold thickness) affected NMES current intensity and NMES-evoked torque, but had no effect on discomfort perception. Our findings may help physical therapists to better understand the impact of SFT on NMES and to design more rational stimulation strategies.
引用
收藏
页码:466 / 472
页数:7
相关论文
共 28 条
[1]   MAPPING OF ELECTRICAL MUSCLE STIMULATION USING MRI [J].
ADAMS, GR ;
HARRIS, RT ;
WOODARD, D ;
DUDLEY, GA .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (02) :532-537
[2]   HIGH-VOLTAGE STIMULATION - EFFECTS OF ELECTRODE SIZE ON BASIC EXCITATORY RESPONSES [J].
ALON, G .
PHYSICAL THERAPY, 1985, 65 (06) :890-895
[3]  
[Anonymous], JESIP
[4]   Does neuromuscular electrical stimulation strengthen the quadriceps femoris? A systematic review of randomised controlled trials [J].
Bax, L ;
Staes, F ;
Verhagen, A .
SPORTS MEDICINE, 2005, 35 (03) :191-212
[5]   CUTANEOUS VERSUS MUSCULAR PERCEPTION OF ELECTRICALLY EVOKED TETANIC PAIN [J].
BELANGER, AY ;
ALLEN, ME ;
CHAPMAN, AE .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (04) :162-168
[6]   COMPARISON BETWEEN THE EFFECTS OF 4 DIFFERENT ELECTRICAL STIMULATION CURRENT WAVEFORMS ON ISOMETRIC KNEE EXTENSION TORQUE AND PERCEIVED DISCOMFORT IN HEALTHY WOMEN [J].
Dantas, Lucas Ogura ;
Vieira, Amilton ;
Siqueira Junior, Aristides Leite ;
Salvini, Tania Fatima ;
Quagliotti Durigan, Joao Luiz .
MUSCLE & NERVE, 2015, 51 (01) :76-82
[7]   COMPARATIVE COMFORT OF 3 WAVE-FORMS USED IN ELECTRICALLY ELICITING QUADRICEPS FEMORIS MUSCLE CONTRACTIONS [J].
DELITTO, A ;
ROSE, SJ .
PHYSICAL THERAPY, 1986, 66 (11) :1704-1707
[8]  
DELITTO A, 1992, PHYS THER, V72, P410, DOI 10.1093/ptj/72.6.410
[9]   The Effect of Subcutaneous Fat Thickness on the Efficacy of Transcutaneous Electrical Stimulation [J].
Doheny, Erner R. ;
Caulfield, Brian M. ;
Minogue, Conor M. ;
Lowery, Madeleine M. .
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, :5684-+
[10]   NEUROMUSCULAR ELECTRICAL STIMULATION ALTERS GENE EXPRESSION AND DELAYS QUADRICEPS MUSCLE ATROPHY OF RATS AFTER ANTERIOR CRUCIATE LIGAMENT TRANSECTION [J].
Durigan, Joao L. Q. ;
Delfino, Gabriel B. ;
Peviani, Sabrina M. ;
Russo, Thiago L. ;
Ramirez, Carolina ;
DaSilva Gomes, Andre D. B. ;
Salvini, Tania F. .
MUSCLE & NERVE, 2014, 49 (01) :120-128