Skinfold thickness affects the isometric knee extension torque evoked by Neuromuscular Electrical Stimulation

被引:19
|
作者
Medeiros, Flavia V. A. [1 ]
Vieira, Amilton [2 ]
Carregaro, Rodrigo L. [3 ]
Bottaro, Martim [1 ]
Maffiuletti, Nicola A. [4 ]
Durigan, Joao L. Q. [3 ]
机构
[1] Univ Brasalia UnB, Fac Educ Fis, Brasilia, DF, Brazil
[2] Univ Brasalia UnB, Fac Ciencias Saude, Brasilia, DF, Brazil
[3] Univ Brasalia UnB, Dept Fisioterapia, Brasilia, DF, Brazil
[4] Schulthess Klin, Neuromuscular Res Lab, Zurich, Switzerland
关键词
physical therapy; physical agents; electrotherapy; QUADRICEPS FEMORIS; ELECTRODE SIZE; HEALTHY WOMEN; WAVE-FORMS; MUSCLE; PAIN; DISCOMFORT; PERCEPTION; ALTERS; FAT;
D O I
10.1590/bjpt-rbf.2014.0114
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Subcutaneous adipose tissue may influence the transmission of electrical stimuli through to the skin, thus affecting both evoked torque and comfort perception associated with neuromuscular electrical stimulation (NMES). This could seriously affect the effectiveness of NMES for either rehabilitation or sports purposes. Objective: To investigate the effects of skinfold thickness (SFT) on maximal NMES current intensity, NMES-evoked torque, and NMES-induced discomfort. Method: First, we compared NMES current intensity, NMES-induced discomfort, and NMES-evoked torque between two subgroups of subjects with thicker (n= 10; 20.7 mm) vs. thinner (n= 10; 29.4 mm) SFT. Second, we correlated SFT to NMES current intensity, NMES-induced discomfort, and NMES-evoked knee extension torque in 20 healthy women. The NMES-evoked torque was normalized to the maximal voluntary contraction (MVC) torque. The discomfort induced by NMES was assessed with a visual analog scale (VAS). Results: NMES-evoked torque was 27.5% lower in subjects with thicker SFT (p=0.01) while maximal current intensity was 24.2% lower in subjects with thinner SFT (p=0.01). A positive correlation was found between current intensity and SFT (r=0.540, p=0.017). A negative correlation was found between NMES-evoked torque and SFT (r=-0.563, p=0.012). No significant correlation was observed between discomfort scores and SFT (r(s)=0.15, p=0.53). Conclusion: These results suggest that the amount of subcutaneous adipose tissue (as reflected by skinfold thickness) affected NMES current intensity and NMES-evoked torque, but had no effect on discomfort perception. Our findings may help physical therapists to better understand the impact of SFT on NMES and to design more rational stimulation strategies.
引用
收藏
页码:466 / 472
页数:7
相关论文
共 50 条
  • [1] Skinfold Thickness Affects The Physiological Response To Neuromuscular Electrical Stimulation
    Medeiros, Flavia
    Vieira, Amilton
    Bottaro, Martim
    Maffiuletti, Nicola
    Durigan, Joao
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 403 - 403
  • [2] EFFECT OF ELECTRICAL-STIMULATION CURRENT FREQUENCIES ON ISOMETRIC KNEE EXTENSION TORQUE
    KRAMER, JF
    PHYSICAL THERAPY, 1987, 67 (01): : 31 - 38
  • [3] The effect of rest intervals on knee-extension torque production with neuromuscular electrical stimulation
    Holcomb, WR
    Rubley, MD
    Miller, MG
    Girouard, TJ
    JOURNAL OF SPORT REHABILITATION, 2006, 15 (02) : 116 - 124
  • [4] Effect Of Neuromuscular Electrical Stimulation On Peak Torque Knee Joint
    Medeiros, Flavia
    Vieira, Amilton
    Bottaro, Martim
    Durigan, Joao
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 671 - 671
  • [5] Contribution of Each Motor Point of Quadriceps Femoris to Knee Extension Torque During Neuromuscular Electrical Stimulation
    Lim, Derrick
    Del Castillo, Mikael
    Bergquist, Austin J.
    Milosevic, Matija
    Masani, Kei
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2021, 29 (29) : 389 - 396
  • [6] SVR modelling of mechanomyographic signals predicts neuromuscular stimulation-evoked knee torque in paralyzed quadriceps muscles undergoing knee extension exercise
    Ibitoye, Morufu Olusola
    Hamzaid, Nur Azah
    Wahab, Ahmad Khairi Abdul
    Hasnan, Nazirah
    Olatunji, Sunday Olusanya
    Davis, Glen M.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2020, 117
  • [7] Isometric Torque Control for Neuromuscular Electrical Stimulation With Time-Varying Input Delay
    Merad, Manelle
    Downey, Ryan J.
    Obuz, Serhat
    Dixon, Warren E.
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2016, 24 (03) : 971 - 978
  • [8] A Study on the Nonlinearity Relationship between Quadriceps Thickness and Torque Output during Isometric Knee Extension
    Chen, Xing
    Chen, Xin
    Li, Jizhou
    Zhou, Yongjin
    HEALTH INFORMATION SCIENCE, HIS 2014, 2014, 8423 : 47 - 54
  • [9] RELATIONSHIP OF ISOMETRIC KNEE EXTENSION TORQUE AND FUNCTIONAL VARIABLES IN OSTEOARTHROSIS OF THE KNEE
    LANKHORST, GJ
    VANDESTADT, RJ
    VANDERKORST, JK
    HINLOPENBONRATH, E
    GRIFFIOEN, FMM
    DEBOER, W
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1982, 14 (01): : 7 - 10
  • [10] COMPARISON BETWEEN THE EFFECTS OF 4 DIFFERENT ELECTRICAL STIMULATION CURRENT WAVEFORMS ON ISOMETRIC KNEE EXTENSION TORQUE AND PERCEIVED DISCOMFORT IN HEALTHY WOMEN
    Dantas, Lucas Ogura
    Vieira, Amilton
    Siqueira Junior, Aristides Leite
    Salvini, Tania Fatima
    Quagliotti Durigan, Joao Luiz
    MUSCLE & NERVE, 2015, 51 (01) : 76 - 82