Automatic estimation of midline shift in patients with cerebral glioma based on enhanced voigt model and local symmetry

被引:12
作者
Chen, Mingyang [1 ,2 ]
Elazab, Ahmed [1 ,2 ]
Jia, Fucang [1 ,2 ]
Wu, Jianhuang [1 ,2 ]
Li, Guanglin [1 ,2 ]
Li, Xiaodong [3 ]
Hu, Qingmao [1 ,2 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen, Peoples R China
[2] Univ Chinese Acad Sci, Beijing, Peoples R China
[3] Linyi Peoples Hosp, Linyi, Peoples R China
关键词
Deformed midline; Cerebral glioma; Mechanical model; Local symmetry; Magnetic resonance imaging; LEVEL SET METHOD; MECHANICAL-PROPERTIES; DEFORMED MIDLINE; BRAIN-TISSUE;
D O I
10.1007/s13246-015-0372-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cerebral glioma is one of the most aggressive space-occupying diseases, which will exhibit midline shift (MLS) due to mass effect. MLS has been used as an important feature for evaluating the pathological severity and patients' survival possibility. Automatic quantification of MLS is challenging due to deformation, complex shape and complex grayscale distribution. An automatic method is proposed and validated to estimate MLS in patients with gliomas diagnosed using magnetic resonance imaging (MRI). The deformed midline is approximated by combining mechanical model and local symmetry. An enhanced Voigt model which takes into account the size and spatial information of lesion is devised to predict the deformed midline. A composite local symmetry combining local intensity symmetry and local intensity gradient symmetry is proposed to refine the predicted midline within a local window whose size is determined according to the pinhole camera model. To enhance the MLS accuracy, the axial slice with maximum MSL from each volumetric data has been interpolated from a spatial resolution of 1 mm to 0.33 mm. The proposed method has been validated on 30 publicly available clinical head MRI scans presenting with MLS. It delineates the deformed midline with maximum MLS and yields a mean difference of 0.61 +/- A 0.27 mm, and average maximum difference of 1.89 +/- A 1.18 mm from the ground truth. Experiments show that the proposed method will yield better accuracy with the geometric center of pathology being the geometric center of tumor and the pathological region being the whole lesion. It has also been shown that the proposed composite local symmetry achieves significantly higher accuracy than the traditional local intensity symmetry and the local intensity gradient symmetry. To the best of our knowledge, for delineation of deformed midline, this is the first report on both quantification of gliomas and from MRI, which hopefully will provide valuable information for diagnosis and therapy. The study suggests that the size of the whole lesion and the location of tumor (instead of edema or the sum of edema and tumor) are more appropriate to determine the extent of deformation. Composite local symmetry is recommended to represent the local symmetry around the deformed midline. The proposed method could be potentially used to quantify the severity of patients with cerebral gliomas and other brain pathology, as well as to approximate midsagittal surface for brain quantification.
引用
收藏
页码:627 / 641
页数:15
相关论文
共 27 条
  • [1] [Anonymous], 1994, Scale-Space Theory in Computer Vision
  • [2] Histograms of oriented gradients for human detection
    Dalal, N
    Triggs, B
    [J]. 2005 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOL 1, PROCEEDINGS, 2005, : 886 - 893
  • [3] Davidson RichardJ., 1996, Brain Asymmetry
  • [4] The prognostic significance of midline shift at presentation on survival in patients with glioblastoma multiforme
    Gamburg, ES
    Regine, WF
    Patchell, RA
    Strottmann, JM
    Mohiuddin, M
    Young, AB
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (05): : 1359 - 1362
  • [5] Nonlinear viscoelastic, thermodynamically consistent, models for biological soft tissue
    Haslach, HW
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2005, 3 (03) : 172 - 189
  • [6] Hauagge DC, 2012, PROC CVPR IEEE, P206, DOI 10.1109/CVPR.2012.6247677
  • [7] A rapid algorithm for robust and automatic extraction of the midsagittal plane of the human cerebrum from neuroimages based on local symmetry and outlier removal
    Hu, QM
    Nowinski, WL
    [J]. NEUROIMAGE, 2003, 20 (04) : 2153 - 2165
  • [8] Joseph D, 1990, Applied Mathematical Sciences, V84
  • [9] Noninvasive assessment of the rheological behavior of human organs using multifrequency MR elastography: a study of brain and liver viscoelasticity
    Klatt, Dieter
    Hamhaber, Uwe
    Asbach, Patrick
    Braun, Juergen
    Sack, Ingolf
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (24) : 7281 - 7294
  • [10] Brain and other central nervous system cancers: Recent trends in incidence and mortality
    Legler, JM
    Ries, LAG
    Smith, MA
    Warren, JL
    Heineman, EF
    Kaplan, RS
    Linet, MS
    [J]. JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1999, 91 (16): : 1382 - 1390