Methodological variation in headspace analysis of liquid samples using electronic nose

被引:19
作者
Knobloch, Henri [1 ]
Turner, Claire [1 ]
Spooner, Andrew [1 ]
Chambers, Mark [2 ]
机构
[1] Cranfield Univ, Cranfield MK43 0AL, Beds, England
[2] Vet Labs Agcy, Dept Statutory & Exot Bacterial Dis, TB Res Grp, Addlestone KT15 3NB, Surrey, England
关键词
Electronic nose; Temperature effect; Headspace; Filter; Sampling method; CONDUCTING POLYMER INTERACTION; GAS SENSORS; GASEOUS SUBSTANCES; WASTE-WATER; IDENTIFICATION; SYSTEM; ARRAY; CLASSIFICATION; EMISSIONS; PRODUCTS;
D O I
10.1016/j.snb.2009.03.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In past years, numerous electronic nose (e-nose) developments have been Published describing analyses of solid-, liquid- or gaseous media in microbiological-, environmental-, agricultural- or medical applications. However, little has been reported about complex methodological pitfalls that might be associated with commercially available e-nose technology. In this paper, some of these pitfalls such as temperature, the use of filters and mass flow using different sampling methods (static- and dynamic sampling) are described for two generations of conducting polymer e-noses (ST114/214, CPs, both Scensive Tech. Ltd.). A comparison with metal oxide semiconducting field effect transistor/metal oxide semiconductor (MOSFET/MOS) e-noses regarding stability across replicates and over time was made. Changes in temperature were found to give larger sensor responses, whereas the application of filters led to quantitative and qualitative changes in sensor responses due to a change in mass flow which was also affected by the sampling method. Static sampling provided more stable flows across replicates. Variation was investigated for CPs and MOSFET/MOS e-noses that gave different responses over time and across replicates. These methodological factors cause a lack of stability and reproducibility, demonstrating the pitfalls of e-nose technology and therefore limit their utility for discriminating between samples. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:353 / 360
页数:8
相关论文
共 37 条
[1]   Classification of unifloral honeys with an MS-based electronic nose using different sampling modes: SHS, SPME and INDEX [J].
Ampuero, S ;
Bogdanov, S ;
Bosset, JO .
EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2004, 218 (02) :198-207
[2]   The electronic nose applied to dairy products: a review [J].
Ampuero, S ;
Bosset, JO .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 94 (01) :1-12
[3]   Comparison of an electronic nose with the sensory evaluation of food products by "triangle test" [J].
Benedetti, S ;
Pompei, C ;
Mannino, S .
ELECTROANALYSIS, 2004, 16 (21) :1801-1805
[4]   Use of a chemical sensor array for detecting pollutants in domestic wastewater [J].
Bourgeois, W ;
Stuetz, RM .
WATER RESEARCH, 2002, 36 (18) :4505-4512
[5]   Application of electronic noses for disease diagnosis and food spoilage detection [J].
Casalinuovo, Ida A. ;
Di Pierro, Donato ;
Coletta, Massimiliano ;
Di Francesco, Paolo .
SENSORS, 2006, 6 (11) :1428-1439
[6]   A neural approach for improving the measurement capability of an electronic nose [J].
Chimenti, M ;
De Rossi, D ;
Di Francesco, F ;
Domenici, C ;
Pieri, G ;
Pioggia, G ;
Salvetti, O .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (06) :815-821
[7]   Sensing behaviors of polypyrrole sensor under humidity condition [J].
Cho, JH ;
Yu, JB ;
Kim, JS ;
Sohn, SO ;
Lee, DD ;
Huh, JS .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) :389-392
[8]   A radially symmetric measurement chamber for electronic noses [J].
Di Francesco, F ;
Falcitelli, M ;
Marano, L ;
Pioggia, G .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 105 (02) :295-303
[9]   Lung cancer identification by the analysis of breath by means of an array of non-selective gas sensors [J].
Di Natale, C ;
Macagnano, A ;
Martinelli, E ;
Paolesse, R ;
D'Arcangelo, G ;
Roscioni, C ;
Finazzi-Agrò, A ;
D'Amico, A .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (10) :1209-1218
[10]   Counteraction of environmental disturbances of electronic nose data by independent component analysis [J].
Di Natale, C ;
Martinelli, E ;
D'Amico, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 82 (2-3) :158-165