Intraoperative complications of revision hip arthroplasty using a porous-coated, distally slotted, fluted femoral stem

被引:15
作者
Issack, PS
Guerin, J
Butler, A
Marwin, SE
Bourne, RB
Rorabeck, CH
Barrack, RL
Di Cesare, PE
机构
[1] NYU, Hosp Joint Dis, Musculoskeletal Res Ctr, Inst Orthopaed,Dept Orthopaed Surg, New York, NY 10003 USA
[2] Univ Western Ontario, London Hlth Sci Ctr, London, ON, Canada
[3] Tulane Univ, Sch Med, Dept Orthopaed Surg, New Orleans, LA 70118 USA
[4] Long Isl Jewish Med Ctr, Dept Orthopaed Surg, New Hyde Pk, NY 11042 USA
关键词
D O I
10.1097/01.blo.0000137290.48374.6b
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Intraoperative complications of 175 cementless revision total hip arthroplasties done at four institutions using a porous-coated, uncemented, distally slotted, fluted femoral stem were reviewed. Three types of complications were recorded: eccentric reaming, femoral perforation, and femoral fracture. Intraoperative complications occurred in 16 patients (9.1%). There was no statistically significant association between complication rate and type of surgical approach, stem length, stem diameter, or host bone quality. This complication rate is comparable to or lower than that reported with the use of similar uncemented long femoral revision stems.
引用
收藏
页码:173 / 176
页数:4
相关论文
共 21 条
  • [1] The use of rhBMP-2 in interbody fusion cages - Definitive evidence of osteoinduction in humans: A preliminary report
    Boden, SD
    Zdeblick, TA
    Sandhu, HS
    Heim, SE
    [J]. SPINE, 2000, 25 (03) : 376 - 381
  • [2] RESULTS OF REVISION FOR MECHANICAL FAILURE AFTER CEMENTED TOTAL HIP-REPLACEMENT, 1979 TO 1982 - A 2 TO 5-YEAR FOLLOW-UP
    CALLAGHAN, JJ
    SALVATI, EA
    PELLICCI, PM
    WILSON, PD
    RANAWAT, CS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) : 1074 - 1085
  • [3] DOHMAE Y, 1988, CLIN ORTHOP RELAT R, P214
  • [4] Intraoperative complications of revision hip arthroplasty using a fully porous-coated straight cobalt-chrome femoral stem
    Egan, KJ
    DiCesare, PE
    [J]. JOURNAL OF ARTHROPLASTY, 1995, 10 : S45 - S51
  • [5] FITZGERALD RH, 1988, CLIN ORTHOP RELAT R, P61
  • [6] RESULTS OF REVISION OF TOTAL HIP-ARTHROPLASTY
    HUNTER, GA
    WELSH, RP
    CAMERON, HU
    BAILEY, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1979, 61 (04): : 419 - 421
  • [7] Long-term results of revision total hip arthroplasty with improved cementing technique
    Katz, RP
    Callaghan, JJ
    Sullivan, PM
    Johnston, RC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (02): : 322 - 326
  • [8] REVISION TOTAL HIP-ARTHROPLASTY
    KAVANAGH, BF
    ILSTRUP, DM
    FITZGERALD, RH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (04) : 517 - 526
  • [9] 5- to 13-year follow-up study on cementless femoral components in revision surgery
    Krishnamurthy, AB
    MacDonald, SJ
    Paprosky, WG
    [J]. JOURNAL OF ARTHROPLASTY, 1997, 12 (08) : 839 - 847
  • [10] OUTCOME OF REVISION HIP-ARTHROPLASTY DONE WITHOUT CEMENT
    LAWRENCE, JM
    ENGH, CA
    MACALINO, GE
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (07) : 965 - 973