摘要
Purpose The analysis of MET gene copy number (CN) has been considered to be a potential bio-marker to predict the response to MET-targeted therapies in various cancers. However, the current standard methods to determine MET CN are SNP 6.0 in the genomic DNA of cancer cell lines and fluorescence in situ hybridization (FISH) in tumor models, respectively, which are costly and require advanced technical skills and result in relatively subjective judgments. Therefore, we employed a novel method, droplet digital PCR (ddPCR), to determine the MET gene copy number with high accuracy and precision. Methods The genomic DNA of cancer cell lines or tumor models were tested and compared with the MET gene CN and MET/CEN-7 ratio determined by SNP 6.0 and FISH, respectively. Results In cell lines, the linear association of the MET CN detected by ddPCR and SNP 6.0 is strong (Pearson correlation = 0.867). In tumor models, the MET CN detected by ddPCR was significantly different between the MET gene amplification and non-amplification groups according to FISH (mean: 15.4 vs 2.1; P = 0.044). Given that MET gene amplification is defined as MET CN >5.5 by ddPCR, the concordance rate between ddPCR and FISH was 98.0%, and Cohen's kappa coefficient was 0.760 (95% CI, 0.498-1.000; P < 0.001). Conclusions The results demonstrated that the ddPCR method has the potential to quantify the MET gene copy number with high precision and accuracy as compared with the results from SNP 6.0 and FISH in cancer cell lines and tumor samples, respectively.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Droplet digital PCR in validating copy number variations in hereditary prostate cancer families from Louisiana
    Wood, Kirsten
    Gambhira, Ratish
    Ledet, Elise
    Sartor, Oliver
    Mandel, Diptasri
    CANCER RESEARCH, 2016, 76
  • [22] Droplet Volume Variability and Impact on Digital PCR Copy Number Concentration Measurements
    Emslie, Kerry R.
    McLaughlin, Jacob L. H.
    Griffiths, Kate
    Forbes-Smith, Michael
    Pinheiro, Leonardo B.
    Burke, Daniel G.
    ANALYTICAL CHEMISTRY, 2019, 91 (06) : 4124 - 4131
  • [23] Detection and Quantification of Chimeric Antigen Receptor Transgene Copy Number by Droplet Digital PCR versus Real-Time PCR
    Lou, Yaoyao
    Chen, Caixia
    Long, Xiaolu
    Gu, Jia
    Xiao, Min
    Wang, Di
    Zhou, Xiaoxi
    Li, Tongjuan
    Hong, Zhenya
    Li, Chunrui
    Zhou, Jianfeng
    Chen, Liting
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2020, 22 (05): : 699 - 707
  • [24] Using droplet digital PCR to analyze MYCN and ALK copy number in plasma from patients with neuroblastoma
    Lodrini, Marco
    Spruessel, Annika
    Astrahantseff, Kathy
    Tiburtius, Daniela
    Konschak, Robert
    Lode, Holger N.
    Fischer, Matthias
    Keilholz, Ulrich
    Eggert, Angelika
    Deubzer, Hedwig E.
    ONCOTARGET, 2017, 8 (49) : 85234 - 85251
  • [25] Accurate Determination of Plasmid Copy Number of Flow-Sorted Cells using Droplet Digital PCR
    Jahn, Michael
    Vorpahl, Carsten
    Tuerkowsky, Dominique
    Lindmeyer, Martin
    Buehler, Bruno
    Harms, Hauke
    Mueller, Susann
    ANALYTICAL CHEMISTRY, 2014, 86 (12) : 5969 - 5976
  • [26] Application of droplet digital PCR for the detection of vector copy number in clinical CAR/TCR T cell products
    Alex Lu
    Hui Liu
    Rongye Shi
    Yihua Cai
    Jinxia Ma
    Lipei Shao
    Victor Rong
    Nikolaos Gkitsas
    Hong Lei
    Steven L. Highfill
    Sandhya Panch
    David F. Stroncek
    Ping Jin
    Journal of Translational Medicine, 18
  • [27] Application of droplet digital PCR for the detection of vector copy number in clinical CAR/TCR T cell products
    Lu, Alex
    Liu, Hui
    Shi, Rongye
    Cai, Yihua
    Ma, Jinxia
    Shao, Lipei
    Rong, Victor
    Gkitsas, Nikolaos
    Lei, Hong
    Highfill, Steven L.
    Panch, Sandhya
    Stroncek, David F.
    Jin, Ping
    JOURNAL OF TRANSLATIONAL MEDICINE, 2020, 18 (01)
  • [28] Clinical implications of MET gene copy number in lung cancer
    Toschi, Luca
    Cappuzzo, Federico
    FUTURE ONCOLOGY, 2010, 6 (02) : 239 - 247
  • [29] Precise quantitation and sensitive detection of copy number within genetic variations using ligation-mediated droplet digital PCR in plasma
    Tian, Hui
    Duan, Mingyue
    Wei, Pingping
    Hu, Fei
    Zhao, Shuhao
    Zhang, Zengming
    Peng, Niancai
    ANALYTICAL METHODS, 2019, 11 (45) : 5761 - 5767
  • [30] HER-2 copy number measurement in tissue and cell-free plasma DNA of gastric cancer patients using droplet digital PCR method
    Kim, Boram
    Nam, Soo Kyung
    Seo, Soo Hyun
    Ahn, Sang-Hoon
    Park, Do Joong
    Kim, Hyung-Ho
    Park, Kyoung Un
    Lee, Hye Seoung
    CANCER RESEARCH, 2018, 78 (13)