Label-free optical-resolution photoacoustic microscopy of superficial microvasculature using a compact visible laser diode excitation

被引:48
作者
Zeng, Lvming [1 ,2 ]
Piao, Zhonglie [2 ]
Huang, Shenghai [2 ]
Jia, Wangcun [2 ]
Chen, Zhongping [2 ,3 ]
机构
[1] Jiangxi Sci & Technol Normal Univ, Key Lab Opt Elect & Commun, Nanchang 330038, Peoples R China
[2] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92612 USA
[3] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
基金
美国国家卫生研究院;
关键词
IN-VIVO; HIGH-SPEED; CODED EXCITATION; LOW-COST; TOMOGRAPHY; SYSTEM;
D O I
10.1364/OE.23.031026
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have developed laser-diode-based optical-resolution photoacoustic microscopy (LD-OR-PAM) of superficial microvasculature which has the desirable properties of being compact, low-cost, and label-free. A 300-mW visible pulsed laser diode was operated at a 405 +/- 5 nm wavelength with a pulse energy as low as 52 nJ. By using a 3.6 MHz ultrasound transducer, the system was tested on carbon fibers with a lateral resolution of 0.95 mu m and an SNR of 38 dB. The subcutaneous microvasculature on a mouse back was imaged without an exogenous contrast agent which demonstrates the potential of the proposed prototype for skin chromophores. Our eventual goal is to offer a practical and affordable multi-wavelength functional LD-OR-PAM instrument suitable for clinical applications. (c) 2015 Optical Society of America
引用
收藏
页码:31026 / 31033
页数:8
相关论文
共 32 条
[1]   Pulsed near-infrared laser diode excitation system for biomedical photoacoustic imaging [J].
Allen, Thomas J. ;
Beard, Paul C. .
OPTICS LETTERS, 2006, 31 (23) :3462-3464
[2]  
American National Standards Institute Inc (ANSI), 2007, ANSI Z136 1 2007 AM
[3]   Optimized SNR simultaneous multispectral photoacoustic imaging with laser diodes [J].
Beckmann, Martin F. ;
Schwab, Hans-Martin ;
Schmitz, Georg .
OPTICS EXPRESS, 2015, 23 (02) :1816-1828
[4]   Handheld probe integrating laser diode and ultrasound transducer array for ultrasound/photoacoustic dual modality imaging [J].
Daoudi, K. ;
van den Berg, P. J. ;
Rabot, O. ;
Kohl, A. ;
Tisserand, S. ;
Brands, P. ;
Steenbergen, W. .
OPTICS EXPRESS, 2014, 22 (21) :26365-26374
[5]   In vivo optical resolution photoacoustic microscopy using glancing angle-deposited nanostructured Fabry-Perot etalons [J].
Hajireza, Parsin ;
Sorge, Jason ;
Brett, Michael ;
Zemp, Roger .
OPTICS LETTERS, 2015, 40 (07) :1350-1353
[6]   Photoacoustic computed tomography correcting for heterogeneity and attenuation [J].
Huang, Chao ;
Nie, Liming ;
Schoonover, Robert W. ;
Wang, Lihong V. ;
Anastasio, Mark A. .
JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (06)
[7]   Fabrication of micro-axicons using direct-laser writing [J].
Huang, He ;
Chen, Shijie ;
Zou, Hongmei ;
Li, Qing ;
Fu, Jian ;
Lin, Feng ;
Wu, X. .
OPTICS EXPRESS, 2014, 22 (09) :11035-11042
[8]  
Jathoul AP, 2015, NAT PHOTONICS, V9, P239, DOI [10.1038/nphoton.2015.22, 10.1038/NPHOTON.2015.22]
[9]   Measurement of cardiac output by use of noninvasively measured transient hemodilution curves with photoacoustic technology [J].
Kang, Dongyel ;
Huang, Qiaojian ;
Li, Youzhi .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (05) :1445-1452
[10]   In vivo photoacoustic imaging of blood vessels with a pulsed laser diode [J].
Kolkman, Roy G. M. ;
Steenbergen, Wiendelt ;
van Leeuwen, Ton G. .
LASERS IN MEDICAL SCIENCE, 2006, 21 (03) :134-139