Effective thermal management of heat sources in sustainable energy devices using a compact flat thermosyphon

被引:19
作者
Dhanalakota, Praveen [1 ]
Malla, Laxman Kumar [1 ]
Dileep, Hemanth [1 ]
Mahapatra, Pallab Sinha [1 ]
Pattamatta, Arvind [1 ]
机构
[1] Indian Inst Technol Madras, Dept Mech Engn, Chennai 600036, Tamil Nadu, India
关键词
Thermal management; Compact flat thermosyphon; Multiple heat sources; Thermal resistance; Sustainable energy; 2-PHASE CLOSED THERMOSIPHON; NON-CONDENSABLE GAS; LOOP THERMOSIPHON; PERFORMANCE; BEHAVIORS; DESIGN; PLATE; PIPE; FLOW;
D O I
10.1016/j.enconman.2022.116041
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermal management is critical in improving the efficiency, lifespan, and reliability of sustainable energy devices such as LEDs, batteries, and solar cells. The compact flat thermosyphon (CFT) is more reliable for the effective thermal management of multiple heat sources in energy-intensive devices. A comprehensive study on the thermal performance of a two-phase CFT is conducted in the present study. The volume of the CFT is 72 x 24 x 15 mm(3) and is made up of copper. The thermal performance of the CFT is analyzed by varying the filling ratio (20%, 50%, 80%), working fluid (acetone, ethanol, water), number of heat sources, and condenser surface wettability. The best-performing filling ratio is found to be 50%. Water is the best performing working fluid over a wide range of heat fluxes (10 - 70 W/cm(2)) due to high heat capacity, latent heat, and low vapor pressure. The CFT can safely cool up to four heat sources of size 12 x 24 mm(2) at a heat flux of 30 W/cm(2) each. The lifespan of the devices can be increased by 2.49 - 6.62 times when the CFT is used to cool multiple heat sources instead of a cold plate. The superhydrophobic condenser surface further improved the thermal performance of the CFT by 28 - 47% because of the quicker return of condensate and dropwise condensation.
引用
收藏
页数:18
相关论文
共 42 条
  • [21] Thermal performance of a novel flat thermosyphon for avionics thermal management
    Junior, Antonio A. M.
    Mantelli, Marcia B. H.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2019, 202
  • [22] Effects of mass transfer time relaxation parameters on condensation in a thermosyphon
    Kim, Youngchul
    Choi, Jongwook
    Kim, Sungcho
    Zhang, Yuwen
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2015, 29 (12) : 5497 - 5505
  • [23] Thermal performance and flow characteristics of two-phase loop thermosyphons
    Kloczko, Sara
    Faghri, Amir
    [J]. NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2020, 77 (07) : 683 - 701
  • [24] Lee W.H., 1980, Multiph. Transp. Fundam. React. Saf. Appl, V1, P162, DOI [10.1017/9781316597392.007, DOI 10.1017/9781316597392.007]
  • [25] Anomalously enhanced light-emitting diode cooling via nucleate boiling using graphene-nanoplatelets coatings
    Lim, Yi Shen
    Hung, Yew Mun
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 244
  • [26] DESCRIBING THE UNCERTAINTIES IN EXPERIMENTAL RESULTS
    MOFFAT, RJ
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1988, 1 (01) : 3 - 17
  • [27] Experimental investigation of a confined flat two-phase thermosyphon for electronics cooling
    Narcy, Marine
    Lips, Stephane
    Sartre, Valerie
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2018, 96 : 516 - 529
  • [28] Thermal performance enhancement and optimization of two-phase closed thermosyphon with graphene-nanoplatelets coatings
    Ng, Ving Onn
    Yu, Hao
    Wu, Heng An
    Hung, Yew Mun
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 236
  • [29] Heat transfer characteristics of titanium/water two-phase closed thermosyphon
    Qi Baojin
    Zhang Li
    Xu Hong
    Sun Yan
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (09) : 2174 - 2179
  • [30] Design of a self-adjusted jet impingement system for cooling of photovoltaic cells
    Rahimi, Masoud
    Valeh-E-Sheyda, Peyvand
    Parsamoghadam, Mohammad Amin
    Masahi, Mohammad Moein
    Alsairafi, Ammar Abdulaziz
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 83 : 48 - 57