Theoretical variations of the thermal performance of different solar collectors and solar combi systems as function of the varying yearly weather conditions in Denmark

被引:23
作者
Andersen, Elsa [1 ]
Furbo, Simon [1 ]
机构
[1] Tech Univ Denmark, Dept Civil Engn, DK-2800 Lyngby, Denmark
关键词
Measured weather data; Solar radiation variations; Solar heating systems; Solar collectors; Thermal performance; Utilized part of solar radiation; DIFFUSE IRRADIANCE MEASUREMENTS; SHADE RING CORRECTION; RADIATION;
D O I
10.1016/j.solener.2008.10.009
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The thermal performances of solar collectors and solar combi systems with different solar fractions are studied under the influence of the Danish design reference year, DRY data file, and measured weather data from a solar radiation measurement station situated at the Technical University of Denmark in Kgs. Lyngby. The data from DRY data file are used for any location in Denmark. The thermal performances of the solar heating systems are calculated by means of validated computer models. The measured yearly solar radiation varies by approximately 23% in the period from 1990 until 2002, and the investigations show that it is not possible to predict the yearly solar radiation on a tilted surface based on the yearly global radiation. The annual thermal performance of solar combi systems cannot with reasonable approximation be fitted to a linear function of the annual total radiation on the solar collector or the annual global radiation. Solar combi systems with high efficient solar collectors are more influenced by weather variations from one year to another than systems with low efficient solar collectors. The annual thermal performance of solar collectors cannot be predicted from the global radiation, but both the annual thermal performance and the annual utilized solar energy can with a reasonable approximation be fitted to a linear function of the yearly solar radiation on the collector for both flat plate and evacuated tubular solar collectors. Also evacuated tubular solar collectors utilize less sunny years with large parts of diffuse radiation relatively better than flat plate collectors. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:552 / 565
页数:14
相关论文
共 27 条
[1]  
ADSTEN M., 2001, RENEW ENERG, V25, P499
[2]  
ANDERSEN E, 2007, R156 TU DENM, P91
[3]  
[Anonymous], 2001, SOLAR ENG THERMAL PR
[4]   ON SHADOWBAND CORRECTION METHODS FOR DIFFUSE IRRADIANCE MEASUREMENTS [J].
BATLLES, FJ ;
OLMO, FJ ;
ALADOSARBOLEDAS, L .
SOLAR ENERGY, 1995, 54 (02) :105-114
[5]  
CAVALCANTI ESC, 1991, BRAZIL SOLAR ENERGY, V47, P231
[6]  
DRUCK H, 2000, MULTIPORT STORE MODE
[7]  
Hay J., 1980, Proceedings First Canadian Solar Radiation Data Workshop, P59
[8]  
Hottel H., 1942, Trans. ASME (Am. Soc. Mech. Eng.), V64, DOI DOI 10.1115/1.4018980
[9]   STUDY OF THE CORRECTIVE FACTOR INVOLVED WHEN MEASURING THE DIFFUSE SOLAR-RADIATION BY USE OF THE RING METHOD [J].
INEICHEN, P ;
GREMAUD, JM ;
GUISAN, O ;
MERMOUD, A .
SOLAR ENERGY, 1984, 32 (05) :585-590
[10]  
JENSEN KL, 2001, SOLFANGERYDELSER SOL