Distal biceps tendon repair - A biomechanical comparison of intact tendon and 2 repair techniques

被引:80
作者
Idler, Cary S.
Montgomery, William H., III
Lindsey, Derek P.
Badua, Peter A.
Wynne, Garnet F.
Yerby, Scott A.
机构
[1] San Francisco Orthopaed Residency Program, San Francisco, CA USA
[2] St Marys Hosp, San Francisco, CA USA
[3] Varehabil R&D Ctr, Palo Alto, CA USA
[4] ST Francis Med Technol, Alameda, CA USA
关键词
biceps tendon repair; bone tunnel; interference screw; biomechanics; failure strength; stiffness;
D O I
10.1177/0363546505284185
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A variety of techniques have been described for distal biceps tendon reattachment-bone tunnel with transosseous sutures, suture anchors, and interference screw techniques. Hypothesis: There will be no significant difference between the mean failure strength, maximum strength, and stiffness of the intact specimen and repair techniques tested: bone tunnel with transosseous sutures and interference screw. Study Design: Controlled laboratory study. Methods: Nine matched pairs of fresh-frozen human cadaveric elbows were prepared. The intact tendon was pulled from the radial tuberosity; the right and left elbows were randomized to bone tunnels with transosseous sutures or interference screw repair techniques. The repaired specimens were pulled using the same regimen for the intact tendon. Failure strength, maximum strength, and stiffness were measured and compared. Results: The mean failure strength, maximum strength, and stiffness of intact tendons were 204.3 +/- 76.9 N, 221.7 +/- 65.9 N, and 30.1 +/- 12.4 N/mm, respectively; for the interference screw specimens, 178.0 +/- 54.5 N, 192.1 +/- 53.1 N, and 30.4 +/- 9.5 N/mm, respectively; and for the bone tunnel specimens, 124.9 +/- 22.8 N, 206.6 +/- 49.8 N, and 15.9 +/- 5.6 N/mm, respectively. There were no significant differences between measures in the intact and interference screw specimens. Mean failure strength and stiffness of the bone tunnel specimens were significantly lower than those of the intact and interference screw specimens; there was no significant difference between the maximum strengths of the treatments. Interference screw failure occurred abruptly with little plastic deformation in nearly all specimens with the tendon and screw pulling out as a unit, often involving fracture of the radial wall. Two of the bone tunnels failed at the bony bridge; the remainder lost bone-tendon contact as the distal tendon was shredded by the suture. Conclusion: The results suggest interference screw fixation repair is nearly as strong and stiff as the intact tendon and stronger than the bone tunnel repair technique. Clinical Relevance: The interference screw provides better stiffness and failure strength compared with the bone tunnel technique for distal biceps tendon repair. Given the superior mechanical properties, the interference screw technique is recommended as the treatment of choice for biceps tendon rupture repair.
引用
收藏
页码:968 / 974
页数:7
相关论文
共 33 条
  • [1] AGINS HJ, 1988, CLIN ORTHOP RELAT R, P34
  • [2] MUSCLES ACROSS THE ELBOW JOINT - A BIOMECHANICAL ANALYSIS
    AN, KN
    HUI, FC
    MORREY, BF
    LINSCHEID, RL
    CHAO, EY
    [J]. JOURNAL OF BIOMECHANICS, 1981, 14 (10) : 659 - +
  • [3] RUPTURE OF THE DISTAL TENDON OF THE BICEPS BRACHII - OPERATIVE VERSUS NON-OPERATIVE TREATMENT
    BAKER, BE
    BIERWAGEN, D
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (03) : 414 - 417
  • [4] Repair of distal biceps tendon ruptures using a suture anchor and an anterior approach
    Balabaud, L
    Ruiz, C
    Nonnenmacher, J
    Seynaeve, P
    Kehr, P
    Rapp, E
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2004, 29B (02) : 178 - 182
  • [5] Bauman GI, 1934, J BONE JOINT SURG, V16, P966
  • [6] Belli P, 2001, J ULTRAS MED, V20, P587
  • [7] Distal biceps brachii tendon repair - An in vitro biomechanical study of tendon reattachment
    Berlet, GC
    Johnson, JA
    Milne, AD
    Patterson, SD
    King, GJW
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (03) : 428 - 432
  • [8] A METHOD FOR REINSERTION OF THE DISTAL BICEPS BRACHII TENDON
    BOYD, HB
    ANDERSON, LD
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1961, 43 (07) : 1041 - 1043
  • [9] Clinical, functional, and radiographic assessments of the conventional and modified Boyd-Anderson surgical procedures for repair of distal biceps tendon ruptures
    D'Arco, P
    Sitler, M
    Kelly, J
    Moyer, R
    Marchetto, P
    Kimura, I
    Ryan, J
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (02) : 254 - 261
  • [10] REPAIR OF DISTAL BICEPS TENDON RUPTURES IN ATHLETES
    DALESSANDRO, DF
    SHIELDS, CL
    TIBONE, JE
    CHANDLER, RW
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (01) : 114 - 119