New dynamic diamond anvil cells for tera-pascal per second fast compression x-ray diffraction experiments

被引:41
|
作者
Jenei, Zs. [1 ]
Liermann, H. P. [2 ]
Husband, R. [2 ]
Mendez, A. S. J. [2 ]
Pennicard, D. [2 ]
Marquardt, H. [3 ]
O'Bannon, E. F. [1 ]
Pakhomova, A. [2 ]
Konopkova, Z. [2 ,4 ]
Glazyrin, K. [1 ]
Wendt, M. [2 ]
Wenz, S. [2 ]
McBride, E. E. [2 ,7 ]
Morgenroth, W. [5 ]
Winkler, B. [5 ]
Rothkirch, A. [2 ]
Hanfland, M. [6 ]
Evans, W. J. [1 ]
机构
[1] Lawrence Livermore Natl Lab, High Pressure Phys Grp, 7000 East Ave,L-041, Livermore, CA 94550 USA
[2] DESY, Photon Sci, Notkestr 85, D-22607 Hamburg, Germany
[3] Univ Oxford, Dept Earth Sci, South Parks Poad, Oxford OX1 3AN, England
[4] European Xray Free Electron Laser Facil GmbH, Holzkoppel 4, D-22869 Schenefeld, Germany
[5] Goethe Univ Frankfurt, Dept Geosci, Arbeitsgrp Kristallog, D-60438 Frankfurt, Germany
[6] ESPF, European Synchrotron, 71 Ave Martyrs, F-38000 Grenoble, France
[7] SLAC Natl Accelerator Lab, 2575 Sand Hill Pd, Menlo Pk, CA 94025 USA
关键词
EQUATION-OF-STATE; D2O ICE VII; HIGH-PRESSURE; POWDER DIFFRACTION; PHASE-TRANSITIONS; ALPHA-QUARTZ;
D O I
10.1063/1.5098993
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Fast compression experiments performed using dynamic diamond anvil cells (dDACs) employing piezoactuators offer the opportunity to study compression-rate dependent phenomena. In this paper, we describe an experimental setup which allows us to perform time-resolved x-ray diffraction during the fast compression of materials using improved dDACs. The combination of the high flux available using a 25.6 keV x-ray beam focused with a linear array of compound refractive lenses and the two fast GaAs LAMBDA detectors available at the Extreme Conditions Beamline (P02.2) at PETRA III enables the collection of x-ray diffraction patterns at an effective repetition rate of up to 4 kHz. Compression rates of up to 160 TPa/s have been achieved during the compression of gold in a 2.5 ms fast compression using improved dDAC configurations with more powerful piezoactuators. The application of this setup to low-Z compounds at lower compression rates is described, and the high temporal resolution of the setup is demonstrated. The possibility of applying finely tuned pressure profiles opens opportunities for future research, such as using oscillations of the piezoactuator to mimic propagation of seismic waves in the Earth.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Automated pipeline processing X-ray diffraction data from dynamic compression experiments on the Extreme Conditions Beamline of PETRA III
    Karnevskiy, Mikhail
    Glazyrin, Konstantin
    Yu, Yuelong
    Mondal, Anshuman
    Sanchez-Valle, Carmen
    Marquardt, Hauke
    Husband, Rachel J.
    O'Bannon, Earl
    Prescher, Clemens
    Barty, Anton
    Liermann, Hanns-Peter
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2024, 57 : 1217 - 1228
  • [32] Dynamic compression of Ce and Pr with millisecond time-resolved X-ray diffraction
    O'Bannon, Earl F. I. I. I. I. I. I.
    Husband, Rachel J.
    Baer, Bruce J.
    Lipp, Magnus J.
    Liermann, Hanns-Peter
    Evans, William J.
    Jenei, Zsolt
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [33] A design of backing seat and gasket assembly in diamond anvil cell for accurate single crystal x-ray diffraction to 5 GPa
    Komatsu, K.
    Kagi, H.
    Yasuzuka, T.
    Koizumi, T.
    Iizuka, R.
    Sugiyama, K.
    Yokoyama, Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (10)
  • [34] A new internally heated diamond anvil cell system for time-resolved optical and x-ray measurements
    Mijiti, Yimin
    Perri, Marco
    Coquet, Jean
    Nataf, Lucie
    Minicucci, Marco
    Trapananti, Angela
    Irifune, Tetsuo
    Baudelet, Francois
    Di Cicco, Andrea
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (08)
  • [35] Dynamic x-ray diffraction and nanosecond quantification of kinetics of formation of β-zirconium under shock compression
    Kalita, Patricia
    Brown, Justin
    Specht, Paul
    Root, Seth
    White, Melanie
    Smith, Jesse S.
    PHYSICAL REVIEW B, 2020, 102 (06)
  • [36] Novel experimental setup for megahertz X-ray diffraction in a diamond anvil cell at the High Energy Density (HED) instrument of the European X-ray Free-Electron Laser (EuXFEL)
    Liermann, H. P.
    Konopkova, Z.
    Appel, K.
    Prescher, C.
    Schropp, A.
    Cerantola, V
    Husband, R. J.
    McHardy, J. D.
    McMahon, M., I
    McWilliams, R. S.
    Pepin, C. M.
    Mainberger, J.
    Roeper, M.
    Berghaeuser, A.
    Damker, H.
    Talkovski, P.
    Foese, M.
    Kujala, N.
    Ball, O. B.
    Baron, M. A.
    Briggs, R.
    Bykov, M.
    Bykova, E.
    Chantel, J.
    Coleman, A. L.
    Cynn, H.
    Dattelbaum, D.
    Dresselhaus-Marais, L. E.
    Eggert, J. H.
    Ehm, L.
    Evans, W. J.
    Fiquet, G.
    Frost, M.
    Glazyrin, K.
    Goncharov, A. F.
    Hwang, H.
    Jenei, Zs
    Kim, J. Y.
    Langenhorst, F.
    Lee, Y.
    Makita, M.
    Marquardt, H.
    McBride, E. E.
    Merkel, S.
    Morard, G.
    O'Bannon, E. F., III
    Otzen, C.
    Pace, E. J.
    Pelka, A.
    Pigott, J. S.
    JOURNAL OF SYNCHROTRON RADIATION, 2021, 28 (28) : 688 - 706
  • [37] Equation of state of pyrope-almandine solid solution measured using a diamond anvil cell and in situ synchrotron X-ray diffraction
    Huang, Shu
    Chen, Jiuhua
    PHYSICS OF THE EARTH AND PLANETARY INTERIORS, 2014, 228 : 88 - 91
  • [38] In situ synchrotron X-ray diffraction study of the formation of TaB2 from the elements in a laser heated diamond anvil cell
    Winkler, Bjorn
    Juarez-Arellano, Erick A.
    Friedrich, Alexandra
    Bayarjargal, Lkhamsuren
    Schroder, Florian
    Biehler, Jasmin
    Milman, Victor
    Clark, Simon M.
    Yan, Jinyuan
    SOLID STATE SCIENCES, 2010, 12 (12) : 2059 - 2064
  • [39] In situ X-ray diffraction measurements of the fcc-hcp phase transition boundary of an Fe-Ni alloy in an internally heated diamond anvil cell
    Komabayashi, Tetsuya
    Hirose, Kei
    Ohishi, Yasuo
    PHYSICS AND CHEMISTRY OF MINERALS, 2012, 39 (04) : 329 - 338
  • [40] Nitrosonium nitrate (NO+NO3-) structure solution using in situ single-crystal X-ray diffraction in a diamond anvil cell
    Laniel, Dominique
    Winkler, Bjoern
    Koemets, Egor
    Fedotenko, Timofey
    Chariton, Stella
    Milman, Victor
    Glazyrin, Konstantin
    Prakapenka, Vitali
    Dubrovinsky, Leonid
    Dubrovinskaia, Natalia
    IUCRJ, 2021, 8 : 208 - 214