Modeling T1 and T2 relaxation in bovine white matter

被引:22
|
作者
Barta, R. [1 ]
Kalantari, S. [1 ]
Laule, C. [2 ,3 ,4 ]
Vavasour, I. M. [2 ]
MacKay, A. L. [1 ,2 ]
Michal, C. A. [1 ]
机构
[1] Univ British Columbia, Dept Phys & Astron, Vancouver, BC V5Z 1M9, Canada
[2] Univ British Columbia, Dept Radiol, Vancouver, BC, Canada
[3] Univ British Columbia, Dept Pathol & Lab Med, Vancouver, BC V5Z 1M9, Canada
[4] Univ British Columbia, Int Collaborat Repair Discoveries ICORD, Vancouver, BC V5Z 1M9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Bovine white matter; T-1 and T-2 relaxation; Brain; Myelin water; Exchange; Inversion pulse bandwidth; NUCLEAR-MAGNETIC-RESONANCE; LEAST-SQUARES ALGORITHM; SPIN-SPIN RELAXATION; MYELIN WATER; HUMAN BRAIN; IN-VIVO; MULTIPLE-SCLEROSIS; INVERSION-RECOVERY; MULTICOMPONENT T-2; PERIPHERAL-NERVE;
D O I
10.1016/j.jmr.2015.08.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The fundamental basis of T-1 and T-2 contrast in brain MRI is not well understood; recent literature contains conflicting views on the nature of relaxation in white matter (WM). We investigated the effects of inversion pulse bandwidth on measurements of T-1 and T-2 in WM. Hybrid inversion-recovery/Carr-Purcell-Meiboom-Gill experiments with broad or narrow bandwidth inversion pulses were applied to bovine WM in vitro. Data were analysed with the commonly used 1D-non-negative least squares (NNLS) algorithm, a 2D-NNLS algorithm, and a four-pool model which was based upon microscopically distinguishable WM compartments (myelin non-aqueous protons, myelin water, non-myelin nonaqueous protons and intra/extracellular water) and incorporated magnetization exchange between adjacent compartments. 1D-NNLS showed that different T-2 components had different T-1 behaviours and yielded dissimilar results for the two inversion conditions. 2D-NNLS revealed significantly more complicated T-1/T-2 distributions for narrow bandwidth than for broad bandwidth inversion pulses. The four-pool model fits allow physical interpretation of the parameters, fit better than the NNLS techniques, and fits results from both inversion conditions using the same parameters. The results demonstrate that exchange cannot be neglected when analysing experimental inversion recovery data from WM, in part because it can introduce exponential components having negative amplitude coefficients that cannot be correctly modeled with nonnegative fitting techniques. While assignment of an individual T-1 to one particular pool is not possible, the results suggest that under carefully controlled experimental conditions the amplitude of an apparent short T-1 component might be used to quantify myelin water. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:56 / 67
页数:12
相关论文
共 50 条
  • [31] Quantitative evaluation of cerebral white matter in patients with multiple sclerosis using multicomponent T2 mapping
    Baranovicova, Eva
    Mlynarik, Vladimir
    Kantorova, Ema
    Hnilicova, Petra
    Dobrota, Dusan
    NEUROLOGICAL RESEARCH, 2016, 38 (05) : 389 - 396
  • [32] Origin of orientation-dependent R1(=1/T1) relaxation in white matter
    Schyboll, Felix
    Jaekel, Uwe
    Petruccione, Francesco
    Neeb, Heiko
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2713 - 2723
  • [33] IR TrueFISP with a golden-ratio-based radial readout: Fast quantification of T1, T2, and proton density
    Ehses, Philipp
    Seiberlich, Nicole
    Ma, Dan
    Breuer, Felix A.
    Jakob, Peter M.
    Griswold, Mark A.
    Gulani, Vikas
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 71 - 81
  • [34] A rapid measurement of T1/T2: The DECPMG sequence
    Mitchell, J.
    Huerlimann, M. D.
    Fordham, E. J.
    JOURNAL OF MAGNETIC RESONANCE, 2009, 200 (02) : 198 - 206
  • [35] Quantitative assessment of water pools by T1ρ and T2ρ MRI in acute cerebral ischemia of the rat
    Jokivarsi, Kimmo T.
    Niskanen, Juha-Pekka
    Michaeli, Shalom
    Groehn, Heidi I.
    Garwood, Michael
    Kauppinen, Risto A.
    Groehn, Olli H.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2009, 29 (01): : 206 - 216
  • [36] Minimum acquisition methods for simultaneously imaging T1, T2, and proton density with B1 correction and no spin-echoes
    Wang, Guan
    El-Sharkawy, AbdEl-Monem M.
    Bottomley, Paul A.
    JOURNAL OF MAGNETIC RESONANCE, 2014, 242 : 243 - 255
  • [37] Measuring water content using T2 relaxation at 3 T: Phantom validations and simulations
    Meyers, Sandra M.
    Kolind, Shannon H.
    Laule, Cornelia
    MacKay, Alex L.
    MAGNETIC RESONANCE IMAGING, 2016, 34 (03) : 246 - 251
  • [38] Accelerated white matter lesion analysis based on simultaneous T1 and T2* quantification using magnetic resonance fingerprinting and deep learning
    Hermann, Ingo
    Martinez-Heras, Eloy
    Rieger, Benedikt
    Schmidt, Ralf
    Golla, Alena-Kathrin
    Hong, Jia-Sheng
    Lee, Wei-Kai
    Wu Yu-Te
    Nagtegaal, Martijn
    Solana, Elisabeth
    Llufriu, Sara
    Gass, Achim
    Schad, Lothar R.
    Weingaertner, Sebastian
    Zoellner, Frank G.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (01) : 471 - 486
  • [39] T1 and T2 quantification from standard turbo spin echo images
    McPhee, Kelly C.
    Wilman, Alan H.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (03) : 2052 - 2063
  • [40] Comparison of myocardial T1 and T2 values in 3 T with T2*in 1.5 T in patients with iron overload and controls
    Camargo, Gabriel C.
    Rothstein, Tamara
    Junqueira, Flavia P.
    Fernandes, Elsa
    Greiser, Andreas
    Strecker, Ralph
    Pessoa, Viviani
    Lima, Ronaldo S. L.
    Gottlieb, Ilan
    INTERNATIONAL JOURNAL OF HEMATOLOGY, 2016, 103 (05) : 530 - 536