Particle size characterization and emission rates during indoor activities in a house

被引:209
作者
Hussein, Tareq
Glytsos, Thodoros
Ondracek, Jakub
Dohanyosova, Pavla
Zdimal, Vladimir
Hameri, Kaarle
Lazaridis, Mihalis
Smolik, Jiri
Kulmala, Markku
机构
[1] Univ Helsinki, Dept Phys Sci, FIN-00014 Helsinki, Finland
[2] Stockholm Univ, Inst Appl Environm Sci, SE-10691 Stockholm, Sweden
[3] Tech Univ Crete, Dept Environm Engn, GRO-73100 Khania, Greece
[4] Inst Chem Proc Fundamentals, Lab Aerosol Chem & Phys, CZ-16502 Prague 6, Czech Republic
[5] Finnish Inst Occupat Hlth, FIN-00250 Helsinki, Finland
关键词
particle number size distribution; penetration; deposition; natural ventilation; modeling; indoor sources;
D O I
10.1016/j.atmosenv.2006.03.053
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Characterization and emission rates of indoor aerosols have been of great interest. However, few studies have presented quantitative determinations of aerosol particle emissions during indoor activities. In the current study we presented and investigated the physical characteristics and size-fractionated emission rates of indoor aerosol particles during different activities in a house (naturally ventilated) located in Prague, Czech Republic. We utilized a multi-compartment and size-resolved indoor aerosol model (MC-SIAM) to investigate the indoor-to-outdoor relationship of aerosol particles and also to estimate their emission rates. When the windows and the main door were closed for several hours and there were minor indoor activities that did not produce significant amounts of aerosol particles, the particle number concentration showed similar levels at different indoor locations. As expected, the natural ventilation did not provide a controlled indoor-to-outdoor relationship of aerosol particles. As previous studies have emphasized, cooking and tobacco smoking activities are major sources indoors; the total particle number concentration was, respectively, as high as 1.8 X 10(5) and 3.6 x 10(4) cm(-3) with emission rates around 380 and 36cm(-3) s(-1). During intensive cooking activities the outdoor aerosol particle concentrations were also affected even though windows were closed. It seems that a simple model is not able to describe the fate of indoor aerosols within a multi-compartment construction; instead, a numerical and dynamic model with a multicompartment approach is needed. Based on the indoor aerosol model simulations, the deposition rate was comparable to previous studies with friction velocity between 10-30 cm s(-1) and surface area to volume ratio around 2.9-3.1 m(-1). The penetration factor was equivalent to G3 filter standards and the ventilation rate varied between 0.6-1.2 h(-1). Based on the emission rate analysis, aerosol particles produced during tobacco smoking and incense stick burning remain airborne for a longer time than cooking particles. It seems that aerosol particles emitted during tobacco smoking and incense stick burning undergo different processes; therefore, there is a need for a combined physical-chemical indoor aerosol model to better describe the evolution of indoor aerosol particles due to different activities. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4285 / 4307
页数:23
相关论文
共 74 条
  • [21] Hinds W. C., 1999, AEROSOL TECHNOLOGY
  • [22] Indoor and outdoor particle size characterization at a family house in Espoo-Finland
    Hussein, T
    Hämeri, K
    Heikkinen, MSA
    Kulmala, M
    [J]. ATMOSPHERIC ENVIRONMENT, 2005, 39 (20) : 3697 - 3709
  • [23] Emission rates due to indoor activities:: Indoor aerosol model development, evaluation, and applications
    Hussein, T
    Korhonen, H
    Herrmann, E
    Hämeri, KH
    Lehtinen, KEJ
    Kulmala, M
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2005, 39 (11) : 1111 - 1127
  • [24] Hussein T, 2005, BOREAL ENVIRON RES, V10, P337
  • [25] Modal structure and spatial-temporal variations of urban and suburban aerosols in Helsinki -: Finland
    Hussein, T
    Hämeri, KA
    Aalto, PP
    Paatero, P
    Kulmala, M
    [J]. ATMOSPHERIC ENVIRONMENT, 2005, 39 (09) : 1655 - 1668
  • [26] Urban aerosol number size distributions
    Hussein, T
    Puustinen, A
    Aalto, PP
    Mäkelä, JM
    Hämeri, K
    Kulmala, M
    [J]. ATMOSPHERIC CHEMISTRY AND PHYSICS, 2004, 4 : 391 - 411
  • [27] HUSSEIN T, 2004, SCAND J WORK ENV HEA, P54
  • [28] Control strategies for sub-micrometer particles indoors: model study of air filtration and ventilation
    Jamriska, M
    Morawska, L
    Ensor, DS
    [J]. INDOOR AIR, 2003, 13 (02) : 96 - 105
  • [29] Relation between indoor and outdoor exposure to fine particles near a busy arterial road
    Jamriska, M
    Thomas, S
    Morawska, L
    Clark, BA
    [J]. INDOOR AIR, 1999, 9 (02) : 75 - 84
  • [30] Indoor air quality and health
    Jones, AP
    [J]. ATMOSPHERIC ENVIRONMENT, 1999, 33 (28) : 4535 - 4564