Effect of Noise-Optimized Monoenergetic Postprocessing on Diagnostic Accuracy for Detecting Incidental Pulmonary Embolism in Portal-Venous Phase Dual-Energy Computed Tomography

被引:44
|
作者
Weiss, Jakob [1 ]
Notohamiprodjo, Mike [1 ]
Bongers, Malte [1 ]
Schabel, Christoph [1 ]
Mangold, Stefanie [1 ]
Nikolaou, Konstantin [1 ]
Bamberg, Fabian [1 ]
Othman, Ahmed E. [1 ]
机构
[1] Eberhard Karls Univ Tubingen, Dept Diagnost & Intervent Radiol, Tubingen, Germany
关键词
computed tomography; dual-energy CT; dual-source CT; noise-optimized monoenergetic imaging; pulmonary CT angiography; pulmonary embolism; CT ANGIOGRAPHY; RISK-FACTORS; CANCER-PATIENTS; IMAGE-QUALITY; CONTRAST; RECONSTRUCTION; SETTINGS; STRATIFICATION; THROMBOSIS; DATASETS;
D O I
10.1097/RLI.0000000000000319
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to evaluate the diagnostic accuracy of virtual monoenergetic images (MEI+) at low kiloelectronvolt levels for the detection of incidental pulmonary embolism (PE) in oncological follow-up portal-venous phase dual-energy (DE-CTpv) staging. Materials and Methods: Twenty-six patients with incidental PE in DE-CTpv staging, which was confirmed by computed tomography pulmonary angiography (CTPA), were included in this study. In addition, 26 matched control patientswho were negative for PE in both DE-CTpv and CTPA were included. All examinations were performed on a third-generation DE-CT system in single-energy (CTPA) and dual-energymode (DE-CTpv). Subsequently, 2 series of MEI+ data sets were reconstructed at 40 and 55 keV from the DE-CTpv data and compared with CTPA and the linearly blended CTpv images. Diagnostic accuracy and diagnostic confidence were calculated and compared for MEI+ reconstructions and for CTpv images regarding the detection of PE with CTPA as standard of reference. Results: In 3 patients, PE was only detectable in CTPA and in the 40-kV and 55-kVMEI+ reconstructions but not in CTpv images. Diagnostic accuracy increased significantly for both MEI+ series (40 keV; area under the curve [AUC], 0.928; 95% confidence interval [CI], 0.879-0.978; 55 keV; AUC, 0.960; 95% CI, 0.922-0.998) as compared with CTpv (AUC, 0.814; 95% CI, 0.741-0.887; P = 0.004). Diagnostic confidence was rated highest in CTPA (median, 5; range, 3-5) followed by 55-keV MEI+ and 40-keV MEI+ (median, 5; range, 2-5 and median, 5; range, 2-5, respectively) and was lowest for CTpv (median, 4; range, 1-5), with significant differences to CTPA and MEI+ reconstructions (P = 0.001). Conclusions: Monoenergetic image reconstructions fromDE-CT data sets at low kiloelectronvolt levels improve diagnostic accuracy for the detection of incidental PE in oncological follow-up DE-CTpv staging, with the highest subjective diagnostic confidence in MEI+ at 55 keV.
引用
收藏
页码:142 / 147
页数:6
相关论文
共 25 条
  • [21] Noise-optimized virtual monoenergetic images and iodine maps for the detection of venous thrombosis in second-generation dual-energy CT (DECT): an ex vivo phantom study
    Malte N. Bongers
    Christoph Schabel
    Bernhard Krauss
    Ilias Tsiflikas
    Dominik Ketelsen
    Stefanie Mangold
    Claus D. Claussen
    Konstantin Nikolaou
    Christoph Thomas
    European Radiology, 2015, 25 : 1655 - 1664
  • [22] Dual-Energy Computed Tomography-Based Display of Bone Marrow Edema in Incidental Vertebral Compression Fractures Diagnostic Accuracy and Characterization in Oncological Patients Undergoing Routine Staging Computed Tomography
    Frellesen, Claudia
    Azadegan, Mehrnoush
    Martin, Simon S.
    Otani, Katharina
    D'Angelo, Tommaso
    Booz, Christian
    Eichler, Katrin
    Panahi, Bita
    Kaup, Moritz
    Bauer, Ralf W.
    Vogl, Thomas J.
    Wichmann, Julian L.
    INVESTIGATIVE RADIOLOGY, 2018, 53 (07) : 409 - 416
  • [23] Dual-Energy Computed Tomography in Patients With Small Hepatocellular Carcinoma: Utility of Noise-Reduced Monoenergetic Images for the Evaluation of Washout and Image Quality in the Equilibrium Phase
    Matsuda, Megumi
    Tsuda, Takaharu
    Kido, Teruhito
    Tanaka, Hiroaki
    Nishiyama, Hikaru
    Itoh, Toshihide
    Nakao, Kenichi
    Hirooka, Masashi
    Mochizuki, Teruhito
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 937 - 943
  • [24] Iodine Distribution Map in Dual-Energy Computed Tomography Pulmonary Artery Imaging with Rapid kVp Switching for the Diagnostic Analysis and Quantitative Evaluation of Acute Pulmonary Embolism
    Cai, Xiang-Ran
    Feng, You-Zhen
    Qiu, Lin
    Xian, Zhao-Hui
    Yang, Wen-Cai
    Mo, Xu-Kai
    Wang, Xiao-Bai
    ACADEMIC RADIOLOGY, 2015, 22 (06) : 743 - 751
  • [25] Diagnostic accuracy of color-coded virtual noncalcium reconstructions derived from portal venous phase dual-energy CT in the assessment of lumbar disk herniation
    Koch, Vitali
    Albrecht, Moritz H.
    Gruenewald, Leon D.
    Yel, Ibrahim
    Eichler, Katrin
    Gruber-Rouh, Tatjana
    Hammerstingl, Renate M.
    Burck, Iris
    Wichmann, Julian L.
    Alizadeh, Leona S.
    Vogl, Thomas J.
    Lenga, Lukas
    Mader, Christoph
    Martin, Simon S.
    Mazziotti, Silvio
    D'Angelo, Tommaso
    Booz, Christian
    EUROPEAN RADIOLOGY, 2022, 32 (04) : 2168 - 2177